OBJECTIVE: To evaluate the effect of screw insertion torque on the mechanical properties of four 3.5 mm locking systems: New Generation Devices (NGD), Securos (PAX), Synthes (SYN), and Veterinary Orthopedic Implants (VOI). STUDY DESIGN: In vitro mechanical study. METHODS: Screws were inserted at 1.5 Nm, 2.5 Nm, and 3.5 Nm torques, using dedicated drill guides and a calibrated torque screwdriver. Locking mechanisms were tested under shear loading conditions using a custom-design probe. Tests were conducted under displacement control until failure. Load to failure and interface stiffness were compared between and within groups using a two-factor ANOVA (P < .05). Failure modes were described. RESULTS: The SYN group had significantly greater mechanical properties compared to all other groups at any given insertion torque. Insertion torque had a significant effect on the PAX group, increasing the load to failure by 126% when increasing the insertion torque from 1.5 Nm to 3.5 Nm. Insertion torque had no significant effect on the mechanical properties of the VOI group and limited effect on the NGD and SYN groups. Single failure mode, by screw head decoupling or screw shaft fracture, occurred in the SYN and VOI groups, respectively. In contrast, NGD and PAX systems failed through a combination of screw decoupling and/or bending. CONCLUSIONS: Regardless of insertion torque, the SYN locking mechanism showed the highest failure loads, interfacial stiffness as well as consistent failure mode. These findings highlight the dependability of this system. When using the PAX system an insertion torque of at least 2.5 Nm should be recommended. © Copyright 2013 by The American College of Veterinary Surgeons.
OBJECTIVE: To evaluate the effect of screw insertion torque on the mechanical properties of four 3.5 mm locking systems: New Generation Devices (NGD), Securos (PAX ), Synthes (SYN), and Veterinary Orthopedic Implants (VOI). STUDY DESIGN: In vitro mechanical study. METHODS: Screws were inserted at 1.5 Nm, 2.5 Nm, and 3.5 Nm torques, using dedicated drill guides and a calibrated torque screwdriver. Locking mechanisms were tested under shear loading conditions using a custom-design probe. Tests were conducted under displacement control until failure. Load to failure and interface stiffness were compared between and within groups using a two-factor ANOVA (P < .05). Failure modes were described. RESULTS: The SYN group had significantly greater mechanical properties compared to all other groups at any given insertion torque. Insertion torque had a significant effect on the PAX group, increasing the load to failure by 126% when increasing the insertion torque from 1.5 Nm to 3.5 Nm. Insertion torque had no significant effect on the mechanical properties of the VOI group and limited effect on the NGD and SYN groups. Single failure mode, by screw head decoupling or screw shaft fracture , occurred in the SYN and VOI groups, respectively. In contrast, NGD and PAX systems failed through a combination of screw decoupling and/or bending. CONCLUSIONS: Regardless of insertion torque, the SYN locking mechanism showed the highest failure loads, interfacial stiffness as well as consistent failure mode. These findings highlight the dependability of this system. When using the PAX system an insertion torque of at least 2.5 Nm should be recommended. © Copyright 2013 by The American College of Veterinary Surgeons.
Entities: Chemical
Disease
Species
Mesh: See more »
Year: 2013
PMID: 23650869 DOI: 10.1111/j.1532-950X.2013.12023.x
Source DB: PubMed Journal: Vet Surg ISSN: 0161-3499 Impact factor: 1.495