The effectiveness of a near-infrared vascular imaging device to support intravenous cannulation in children with dark skin color: a cluster randomized clinical trial.

Olga C P van der Woude1, Natascha J Cuper, Chavalleh Getrouw, Cor J Kalkman, Jurgen C de Graaff.   

Abstract

BACKGROUND: Poor vein visibility can make IV cannulation challenging in children with dark skin color. In the operating room, we studied the effectiveness of a near-infrared vascular imaging device (VascuLuminator) to facilitate IV cannulation in children with dark skin color.
METHODS: In the operating room of a general hospital in Curacao, all consecutive children (0-15 years of age) requiring IV cannulation were included in a pragmatic cluster randomized clinical trial. The VascuLuminator was made available to anesthesiologists at the operating complex in randomized clusters of 1 week.
RESULTS: Success at first attempt was 63% (27/43, 95% confidence interval [CI], 47%-77%) in the VascuLuminator group vs 51% (23 of 45 patients, 95% CI, 36%-66%) in the control group (P = 0.27). Median time to successful cannulation was 53 seconds (interquartile range: 34-154) in the VascuLuminator group and 68 seconds (interquartile range: 40-159) in the control group (P = 0.54), and hazard ratio was 1.12 (95% CI, 0.73-1.71).
CONCLUSION: The VascuLuminator has limited value in improving success at first attempt of facilitating IV cannulation in children with dark skin color.

Entities:  

Mesh:

Year:  2013        PMID: 23649104     DOI: 10.1213/ANE.0b013e31828e5bde

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

Review 1.  Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis.

Authors:  Joon Min Park; Min Joung Kim; Hyeon Woo Yim; Won-Chul Lee; Hyunsuk Jeong; Na Jin Kim
Journal:  Eur J Pediatr       Date:  2016-10-26       Impact factor: 3.183

2.  Development of a clinical prediction rule to improve peripheral intravenous cannulae first attempt success in the emergency department and reduce post insertion failure rates: the Vascular Access Decisions in the Emergency Room (VADER) study protocol.

Authors:  Peter J Carr; James C R Rippey; Marie L Cooke; Chrianna Bharat; Kevin Murray; Niall S Higgins; Aileen Foale; Claire M Rickard
Journal:  BMJ Open       Date:  2016-02-11       Impact factor: 2.692

Review 3.  Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy.

Authors:  Cheng-Tang Pan; Mark D Francisco; Chung-Kun Yen; Shao-Yu Wang; Yow-Ling Shiue
Journal:  Sensors (Basel)       Date:  2019-08-16       Impact factor: 3.576

4.  Initial experience with use of infrared assistance for intravenous injection of radiopharmaceuticals.

Authors:  Ashok Kumar; Meena Negi; Jyoti Khanka; Mohit Dhingra; Ranjeeta Kumari; Vandana Kumar Dhingra; Manoj Kumar Gupta
Journal:  World J Nucl Med       Date:  2020-10-02

5.  Towards a low-cost mobile subcutaneous vein detection solution using near-infrared spectroscopy.

Authors:  Simon Juric; Vojko Flis; Matjaz Debevc; Andreas Holzinger; Borut Zalik
Journal:  ScientificWorldJournal       Date:  2014-04-30