Literature DB >> 23647613

Ion-pair reversed-phase chromatography of short double-stranded deoxyribonucleic acid in silicon micro-pillar array columns: retention model and applications.

Lei Zhang1, Bivragh Majeed, Liesbet Lagae, Peter Peumans, Chris Van Hoof, Wim De Malsche.   

Abstract

Separation of double-stranded (ds) DNAs is important in numerous biochemical analyses relevant for clinical applications. A widely used separation technique is high performance liquid chromatography (HPLC), in the variant of ion-pair reversed-phase (IP-RP) chromatography. HPLC can be miniaturized by means of silicon micro-pillar array columns leading to on-chip fast and high resolution dsDNA separation with limited sample quantity. However, theoretical studies of retentive behavior of dsDNA in miniaturized chromatographic columns are hardly available, despite their enormous practical relevance. This paper established a new retention model to describe the size dependent separation of dsDNAs for any characteristic of the linear mobile phase gradient, in analogy to the model used to describe the retention of polymer chains with repeating units in RP HPLC. The model agrees with a large amount of dsDNA retention data, measured using DNA molecules in the size range of 10-400 base pairs in columns with different lengths (2 and 40cm) and different micro-pillar sizes (2 and 2.5μm in diameter), in various mobile phase gradients. The model is particularly useful in practice, since it requires no numerical solutions and the column-specific fitting parameters (4 or 5) can be determined in a limited number of separation runs. As examples of its applications, the model has been used for the optimization of dsDNA step-gradient separations (5 dsDNAs separated within 8min) and for the determination of the size of dsDNA fragment (with uncertainty of about 2%). These applications are especially relevant for on-chip DNA analysis devices.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23647613     DOI: 10.1016/j.chroma.2013.04.002

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Advances in and prospects of microchip liquid chromatography.

Authors:  James P Grinias; Robert T Kennedy
Journal:  Trends Analyt Chem       Date:  2016 Jul-Aug       Impact factor: 12.296

2.  Self-ordered anodic porous alumina with inter-hole spacing over 1.5 μm.

Authors:  Takashi Yanagishita; Ryosuke Moriyasu; Takayuki Ishii; Hideki Masuda
Journal:  RSC Adv       Date:  2021-01-19       Impact factor: 3.361

3.  Efficient fabrication of ordered alumina through-hole membranes using a TiO2 protective layer prepared by atomic layer deposition.

Authors:  Takashi Yanagishita; Haruka Itoh; Hideki Masuda
Journal:  RSC Adv       Date:  2022-01-27       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.