Determination of the safe range of graft size mismatch using body surface area index in deceased liver transplantation.

Kyota Fukazawa1, Yoshitsugu Yamada, Seigo Nishida, Taizo Hibi, Kris L Arheart, Ernesto A Pretto.   

Abstract

In live donor liver transplantation, rigorous standardized criteria for matching of liver volume between donor and recipient have prevented graft loss because of size mismatch. In deceased whole liver transplantation, the safe donor-recipient size mismatch range remains unknown. We developed a multivariate survival model (generalized additive model) to estimate hazard risk of body surface area index (BSAi) for 3-year graft survival using data derived from the national registry database between 2005 and 2010. BSAi was calculated by BSA of donor divided by BSA of recipient. 24 509 patients were included in the analysis. Small-for-size (SFS) grafts with BSAi less than 0.78 had a significant impact on graft dysfunction with progressive increase of hazard risk toward the lowest end and a higher incidence of primary graft nonfunction and vascular thrombosis. Large-for-size (LFS) grafts with BSAi greater than 1.24 had a significant impact on graft dysfunction with progressive increase of hazard risk toward the largest end. Our findings suggest that donor grafts with BSAi < 0.78 could be considered 'SFS' and donor grafts with BSAi > 1.24 could be considered 'LFS', with both extremes resulting in decreased graft survival. Therefore, BSAi > 0.78 and <1.24 appears to be a safe range to avoid adverse outcome associated with size mismatch.
© 2013 Steunstichting ESOT. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Year:  2013        PMID: 23647566     DOI: 10.1111/tri.12111

Source DB:  PubMed          Journal:  Transpl Int        ISSN: 0934-0874            Impact factor:   3.782


  4 in total

1.  Quantifying Sex-Based Disparities in Liver Allocation.

Authors:  Jayme E Locke; Brittany A Shelton; Kim M Olthoff; Elizabeth A Pomfret; Kimberly A Forde; Deirdre Sawinski; Meagan Gray; Nancy L Ascher
Journal:  JAMA Surg       Date:  2020-07-15       Impact factor: 14.766

Review 2.  Radiological Screening Methods in Deceased Organ Donation: An Overview of Guidelines Worldwide.

Authors:  K A Chotkan; J W Mensink; R A Pol; N P Van Der Kaaij; L F M Beenen; W N Nijboer; B Schaefer; I P J Alwayn; A E Braat
Journal:  Transpl Int       Date:  2022-05-19       Impact factor: 3.842

3.  Accuracy of estimation of graft size for living-related liver transplantation: first results of a semi-automated interactive software for CT-volumetry.

Authors:  Theresa Mokry; Nadine Bellemann; Dirk Müller; Justo Lorenzo Bermejo; Miriam Klauß; Ulrike Stampfl; Boris Radeleff; Peter Schemmer; Hans-Ulrich Kauczor; Christof-Matthias Sommer
Journal:  PLoS One       Date:  2014-10-17       Impact factor: 3.240

4.  Peak Serum AST Is a Better Predictor of Acute Liver Graft Injury after Liver Transplantation When Adjusted for Donor/Recipient BSA Size Mismatch (ASTi).

Authors:  Kyota Fukazawa; Seigo Nishida; Ernesto A Pretto
Journal:  J Transplant       Date:  2014-06-09