Literature DB >> 23647247

Mechanical properties evolution of a PLGA-PLCL composite scaffold for ligament tissue engineering under static and cyclic traction-torsion in vitro culture conditions.

Cyril J F Kahn1, Kahina Ziani, Ye Min Zhang, Jian Liu, Nguyen Tran, Jérôme Babin, Natalia de Isla, Jean-Luc Six, Xiong Wang.   

Abstract

This study aims to investigate the in vitro degradation of a poly(L-lactic-co-glycolic acid)-poly(L-lactic-co-ϵ-caprolactone) (PLGA-PLCL) composite scaffold's mechanical properties under static culture condition and 2 h period per day of traction-torsion cyclic culture conditions of simultaneous 10% uniaxial strain and 90° of torsion cycles at 0.33 Hz. Scaffolds were cultured in static conditions, during 28 days, with or without cell seeded or under dynamic conditions during 14 days in a bioreactor. Scaffolds' biocompatibility and proliferation were investigated with Alamar Blue tests and cell nuclei staining. Scaffolds' mechanical properties were tested during degradation by uniaxial traction test. The PLGA-PLCL composite scaffold showed a good cytocompatibility and a high degree of colonization in static conditions. Mechanical tests showed a competition between two process of degradation which have been associated to hydrolytic and enzymatic degradation for the reinforce yarn in poly(L-lactic-co-glycolic acid) (PLGA). The enzymatic degradation led to a decrease effect on mechanical properties of cell-seeded scaffolds during the 21st days, but the hydrolytic degradation was preponderant at day 28. In conclusion, the structure of this scaffold is adapted to culture in terms of biocompatibility and cell orientation (microfiber) but must be improved by delaying the degradation of it reinforce structure in PLGA.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23647247     DOI: 10.1080/09205063.2012.727265

Source DB:  PubMed          Journal:  J Biomater Sci Polym Ed        ISSN: 0920-5063            Impact factor:   3.517


  2 in total

Review 1.  Mechanical Actuation Systems for the Phenotype Commitment of Stem Cell-Based Tendon and Ligament Tissue Substitutes.

Authors:  Marco Govoni; Claudio Muscari; Joseph Lovecchio; Carlo Guarnieri; Emanuele Giordano
Journal:  Stem Cell Rev Rep       Date:  2016-04       Impact factor: 5.739

2.  Static and cyclic mechanical loading of mesenchymal stem cells on elastomeric, electrospun polyurethane meshes.

Authors:  Robyn D Cardwell; Jonathan A Kluge; Patrick S Thayer; Scott A Guelcher; Linda A Dahlgren; David L Kaplan; Aaron S Goldstein
Journal:  J Biomech Eng       Date:  2015-06-03       Impact factor: 2.097

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.