Design and validation of an indicator gas injector for multiple gas washout tests in mechanically ventilated patients.

P E Huygen1, B W Feenstra, W P Holland, C Ince, H Stam, H A Bruining.   

Abstract

A device to produce a stepwise indicator gas fraction variation to initiate a washout test in mechanically ventilated patients is described. The device, which can be used in conjunction with the commonly used Siemens-Elema series 900 ventilators, is based on simple, off-the-shelf technology. It features the simultaneous use of two indicator gases (so that the influence of diffusion processes in the gas exchange to the patient can be measured) and maintains a nearly constant FIO2 during a washout procedure. With this indicator gas injector, the transition time of the indicator gas fraction at the beginning of a washout proved to be short enough to detect ventilation inhomogeneity by visual inspection of the washout curves. Functional residual capacity measurements using this device are presented on a test lung with known volume, on healthy volunteers, and on critically ill patients.

Entities:  

Mesh:

Year:  1990        PMID: 2364717     DOI: 10.1097/00003246-199007000-00015

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  5 in total

1.  Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver.

Authors:  Huibert R van Genderingen; Adrianus J van Vught; Jos R C Jansen
Journal:  Intensive Care Med       Date:  2002-12-14       Impact factor: 17.440

2.  Clinical evaluation of diminished early expiratory flow (DEEF) ventilation in mechanically ventilated COPD patients.

Authors:  I Gültuna; P E Huygen; C Ince; H Strijdhorst; J M Bogaard; H A Bruining
Journal:  Intensive Care Med       Date:  1996-06       Impact factor: 17.440

3.  A simple device to inject indicator gas for wash-out tests during mechanical ventilation.

Authors:  I Gültuna; P E Huygen; C Jabaaij; W P Holland; C Ince; H A Bruining
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

4.  Mechanical ventilator for delivery of ¹⁷O₂ in brief pulses.

Authors:  J E Baumgardner; E A Mellon; D R Tailor; K Mallikarjunarao; A Borthakur; R Reddy
Journal:  Open Biomed Eng J       Date:  2008-09-24

5.  Assessment of ventilation inhomogeneity during mechanical ventilation using a rapid-response oxygen sensor-based oxygen washout method.

Authors:  Ido G Bikker; Wim Holland; Patricia Specht; Can Ince; Diederik Gommers
Journal:  Intensive Care Med Exp       Date:  2014-04-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.