Optimization of near infrared fluorescence tumor localization during robotic partial nephrectomy.

Jordan E Angell1, Tariq A Khemees, Ronney Abaza.   

Abstract

PURPOSE: Near infrared fluorescence allows the differentiation of tumors and normal parenchyma during robotic partial nephrectomy. This may facilitate tumor excision but requires proper dosing of indocyanine green. Under dosing causes inadequate fluorescence of peritumor parenchyma. Overdosing causes tumors to fluoresce inappropriately. Currently there are no described dosing strategies to our knowledge to optimize near infrared fluorescence and reported doses vary widely. We devised a dosing strategy and assessed the reliability of near infrared fluorescence for differential fluorescence.
MATERIALS AND METHODS: Robotic partial nephrectomy with near infrared fluorescence was performed for 79 tumors. Dosing strategy involved at minimum 2 indocyanine green doses, including the test dose and the calibrated dose before resection. The test dose was deliberately low to avoid confounding over-fluorescence. The second dose was calibrated depending on the extent of differential fluorescence achieved with the test doses. Intraoperative assessment of tumor fluorescence was recorded before pathological assessment.
RESULTS: Mean tumor size was 3.5 cm (range 1.1 to 9.8) with a mean R.E.N.A.L. score of 8 (range 4 to 12). Median indocyanine green test dose and re-dose before clamping were 1.25 mg (range 0.625 to 2.5) and 1.875 mg (range 0.625 to 5), respectively. Differential fluorescence was achieved in 65 of 79 tumors (82%) that did not fluoresce. After 3 exclusions for the inability to assess fluorescence or indeterminate histology, 60 of 76 tumors were renal cell carcinoma. Of 60 renal cell carcinomas 55 behaved appropriately and did not fluoresce (92%). Overall 65 of 76 tumors behaved appropriately for an 86% agreement between histology and near infrared fluorescence behavior.
CONCLUSIONS: With our dosing regimen near infrared fluorescence was highly reliable in achieving differential fluorescence of kidney and renal cell carcinomas. Standardized dosing is needed before deciding whether near infrared fluorescence improves robotic partial nephrectomy outcomes and additional studies may further improve reliability.
Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ICG; NIRF; RCC; RPN; carcinoma; fluorescence; indocyanine green; near infrared fluorescence; nephrectomy; renal cell; renal cell carcinoma; robotic partial nephrectomy; robotics

Mesh:

Substances:

Year:  2013        PMID: 23643597     DOI: 10.1016/j.juro.2013.04.072

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  16 in total

1.  Vision 20/20: Molecular-guided surgical oncology based upon tumor metabolism or immunologic phenotype: Technological pathways for point of care imaging and intervention.

Authors:  Brian W Pogue; Keith D Paulsen; Kimberley S Samkoe; Jonathan T Elliott; Tayyaba Hasan; Theresa V Strong; Daniel R Draney; Joachim Feldwisch
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

Review 2.  Advances in fluorescent-image guided surgery.

Authors:  Mark J Landau; Daniel J Gould; Ketan M Patel
Journal:  Ann Transl Med       Date:  2016-10

Review 3.  Frontiers in robot-assisted retroperitoneal oncological surgery.

Authors:  Wesley W Ludwig; Michael A Gorin; Phillip M Pierorazio; Mohamad E Allaf
Journal:  Nat Rev Urol       Date:  2017-09-12       Impact factor: 14.432

4.  Best practices in near-infrared fluorescence imaging with indocyanine green (NIRF/ICG)-guided robotic urologic surgery: a systematic review-based expert consensus.

Authors:  Giovanni E Cacciamani; A Shakir; A Tafuri; K Gill; J Han; N Ahmadi; P A Hueber; M Gallucci; G Simone; R Campi; G Vignolini; W C Huang; J Taylor; E Becher; F W B Van Leeuwen; H G Van Der Poel; L P Velet; A K Hemal; A Breda; R Autorino; R Sotelo; M Aron; M M Desai; A L De Castro Abreu
Journal:  World J Urol       Date:  2019-07-08       Impact factor: 4.226

5.  Indocyanine green as a near-infrared fluorescent agent for identifying parathyroid glands during thyroid surgery in dogs.

Authors:  Yong Joon Suh; June Young Choi; Young Jun Chai; Hyungju Kwon; Jung-Woo Woo; Su-Jin Kim; Kyu Hyung Kim; Kyu Eun Lee; Yong Taik Lim; Yeo-Kyu Youn
Journal:  Surg Endosc       Date:  2014-11-27       Impact factor: 4.584

Review 6.  Near-infrared fluorescence imaging with intraoperative administration of indocyanine green for robotic partial nephrectomy.

Authors:  Marc A Bjurlin; Tyler R McClintock; Michael D Stifelman
Journal:  Curr Urol Rep       Date:  2015-04       Impact factor: 3.092

Review 7.  The status of contemporary image-guided modalities in oncologic surgery.

Authors:  Eben L Rosenthal; Jason M Warram; Kirby I Bland; Kurt R Zinn
Journal:  Ann Surg       Date:  2015-01       Impact factor: 12.969

8.  Near-Infrared Fluorescence Imaging of Renal Cell Carcinoma with ASP5354 in a Mouse Model for Intraoperative Guidance.

Authors:  Katsunori Teranishi
Journal:  Int J Mol Sci       Date:  2022-06-29       Impact factor: 6.208

Review 9.  Intraoperative optical imaging and tissue interrogation during urologic surgery.

Authors:  Mark Hsu; Mohit Gupta; Li-Ming Su; Joseph C Liao
Journal:  Curr Opin Urol       Date:  2014-01       Impact factor: 2.309

10.  Evaluation to Differentiate between Tumor Lesions and the Parenchyma in Partial Nephrectomies for Renal Tumors Based on Quantitative Fluorescence Imaging Using Indocyanine Green Dye.

Authors:  Norihito Soga; Akihito Inoko; Jun Furusawa; Yuji Ogura
Journal:  Curr Urol       Date:  2019-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.