PURPOSE: To assess the role of three-dimensional volume rendering (3DVR) in the preoperative assessment of the ossicular chain in chronic suppurative otitis media (CSOM).
MATERIALS AND METHODS: Sixty-six patients with CSOM were included in this prospective study. Temporal bone was scanned with a 128-channel multidetector row CT and the axial data was transferred to the workstation for multiplanar reformation (MPR) and 3DVR reconstructions. Evaluation of the ossicular chain according to a three-point scoring system on two-dimensional reformation (2D) and 3DVR was performed independently by two radiologists. The evaluation results were compared with surgical findings.
RESULTS: 2D showed over 89% accuracy in the assessment of segmental absence of the ossicular chain in CSOM, no matter how small the segmental size was. 3DVR was as accurate as 2D for the assessment of segmental absence. However, 3DVR was found to be more accurate than 2D in the evaluation of partial erosion of segments.
CONCLUSION: Both 3DVR and 2D are accurate and reliable for the assessment of the ossicular chain in CSOM. The inclusion of 3DVR images in the imaging protocol improves the accuracy of 2D in detecting ossicular erosion from CSOM.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Middle ear; Multidetector computed tomography; Ossicles; Otitis media

Mesh:

Year:  2013        PMID: 23643029     DOI: 10.1016/j.ejrad.2013.03.010

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  4 in total

1.  Congenital malformation of the oval window: experience of radiologic diagnosis and surgical technique.

Authors:  Feng Yang; Yang Liu; Jianjun Sun; Jinrang Li; Rendong Song
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-03-13       Impact factor: 2.503

Review 2.  Cinematic rendering - an alternative to volume rendering for 3D computed tomography imaging.

Authors:  Evelyn Dappa; Kai Higashigaito; Jürgen Fornaro; Sebastian Leschka; Simon Wildermuth; Hatem Alkadhi
Journal:  Insights Imaging       Date:  2016-09-15

3.  A Fast 3-Dimensional Magnetic Resonance Imaging Reconstruction for Surgical Planning of Uterine Myomectomy.

Authors:  Sa Ra Lee; Young Jae Kim; Kwang Gi Kim
Journal:  J Korean Med Sci       Date:  2018-01-08       Impact factor: 2.153

4.  Value of section plane, MPR, and 3D-CTVR techniques in the fine differential diagnosis of ossicular chain in the case of conductive hearing loss with intact tympanic membrane.

Authors:  Yang Liu; Feng Yang; QiaoHui Lu; Danheng Zhao
Journal:  J Otol       Date:  2017-03-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.