Literature DB >> 23642799

Comparison of normal and keratoconic corneas by Galilei Dual-Scheimpflug Analyzer.

Selim Demir1, Barış Sönmez, Volkan Yeter, Hüseyin Ortak.   

Abstract

BACKGROUND AND
OBJECTIVE: To determine the efficacy of different Galilei Scheimpflug-Analyzer (GSA) parameters in discriminating between keratoconic and myopic eyes. PATIENTS AND METHODS: GSA measurements were obtained for 67 patients (67 eyes) with keratoconus and 151 patients (151 eyes) with myopia or myopic astigmatism. Several parameters, provided by the software or derived from the elevation maps, were evaluated and compared for the two groups.
RESULTS: Between the two groups, statistically significant differences were observed for all corneal parameters obtained by GSA (P<0.001) except for the anterior chamber depth (P=0.149). ROC analysis determined that posterior corneal elevation was the best predictive parameter (area under the curve: 0.99). The posterior corneal elevation, at a cut-off value of 18.5μm, had 98.5% sensitivity and 98.3% specificity in discriminating keratoconus from myopic eyes.
CONCLUSION: Elevation, pachymetric and keratometric parameters measured by the GSA, as well as the specific predictive GSA software parameters can effectively distinguish advanced keratoconus from myopic corneas. Also, keratoconus that is easily diagnosed by other means can be diagnosed easily by GSA software parameters.
Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anterior segment imaging; Clinical examination; Galilei; Keratoconus; Scheimpflug

Mesh:

Year:  2013        PMID: 23642799     DOI: 10.1016/j.clae.2013.04.001

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  5 in total

1.  Changes in Corneal Morphology and Biomechanics in Cases of Small Incision Lenticule Extraction with Prophylactic Accelerated Collagen Cross-Linking.

Authors:  Fei Mo; Yu Di; Ying Li
Journal:  J Ophthalmol       Date:  2022-07-11       Impact factor: 1.974

2.  Comparison of anterior segment measurements obtained by three different devices in healthy eyes.

Authors:  Carmen Lopez de la Fuente; Ana Sanchez-Cano; Francisco Segura; Isabel Pinilla
Journal:  Biomed Res Int       Date:  2014-06-02       Impact factor: 3.411

Review 3.  Galilei Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part II.

Authors:  Majid Moshirfar; Mahsaw N Motlagh; Michael S Murri; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

4.  Clinical evaluation of ocular biometry of dual Scheimpflug analyzer, GALILEI G6 and swept source optical coherence tomography, ANTERION.

Authors:  Boonsong Wanichwecharungruang; Anyarak Amornpetchsathaporn; Kittipong Kongsomboon; Wisakorn Wongwijitsook; Kornkamol Annopawong; Somporn Chantra
Journal:  Sci Rep       Date:  2022-03-04       Impact factor: 4.379

5.  Comparison of Anterior Chamber Depth between Normal and Keratoconic Eyes: A Systematic Review and Meta-Analysis.

Authors:  Hassan Hashemi; AbbasAli Yekta; Negareh Yazdani; Hadi Ostadimoghaddam; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2020-03-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.