Literature DB >> 23640036

Our perspective of the treatment of naevus of Ota with 1,064-, 755- and 532-nm wavelength lasers.

S J Felton1, F Al-Niaimi, J E Ferguson, V Madan.   

Abstract

Naevus of Ota (NO) is a disfiguring pigmentary disorder affecting the face. Q-switched neodymium-doped yttrium aluminium garnet (QS Nd:YAG)-1,064 nm is a standard laser treatment because it causes highly selective destruction of melanin within the aberrant dermal melanocytes. However, not all lesions respond. This study aims to evaluate the efficacy/safety of QS Nd:YAG-1,064 nm and the shorter wavelength QS Alexandrite-755 nm and QS Nd:YAG-532 nm lasers in treating NO. Data were evaluated from 21 patients treated in our laser centre from 2004 to 2012. Lesional skin was irradiated with QS-532 nm/QS-755 nm/QS-1,064 nm, with settings titrated according to responses. All received initial test patches to direct initial wavelength choice, with subsequent treatments at 3-monthly intervals until clearance/lack of further response. Laser modality was switched following repeated test patches if there was no or no sustained improvement. Two thirds of patients had ≥ 90% improvement compared to baseline photographs. In 20% of patients, QS-1,064 nm was most efficacious with 97% mean improvement. The mean improvement was 80% for those in whom QS-755 nm was superior, and 90% for QS-532 nm. Median number of overall laser treatments was 8 (range 4-13). Number of treatments required varied significantly according to lesional colour and site: grey lesions and those on the forehead/temple were most resistant. We confirm successful treatment of NO with QS Nd:YAG-1,064 nm and the shorter wavelength QS-755 nm/QS-532 nm lasers without serious or irreversible side effects. We recommend judicious test patch analysis before treatment and a modality switch if complete clearance is not obtained.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23640036     DOI: 10.1007/s10103-013-1332-3

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  16 in total

1.  Histopathological parameters determining lesion colours in the naevus of Ota: a morphometric study using computer-assisted image analysis.

Authors:  N-K Rho; W-S Kim; D-Y Lee; J-M Yang; E-S Lee; J-H Lee
Journal:  Br J Dermatol       Date:  2004-06       Impact factor: 9.302

2.  Are Q-switched lasers for Nevus of Ota really effective in pigmented skin?

Authors:  Kabir Sardana; Shikha Chugh; Vijay Garg
Journal:  Indian J Dermatol Venereol Leprol       Date:  2012 Mar-Apr       Impact factor: 2.545

3.  In vivo biophysical characterization of skin physiological differences in races.

Authors:  E Berardesca; J de Rigal; J L Leveque; H I Maibach
Journal:  Dermatologica       Date:  1991

4.  The influence of age and sex on skin thickness, skin collagen and density.

Authors:  S Shuster; M M Black; E McVitie
Journal:  Br J Dermatol       Date:  1975-12       Impact factor: 9.302

Review 5.  Basic laser principles.

Authors:  R M Herd; J S Dover; K A Arndt
Journal:  Dermatol Clin       Date:  1997-07       Impact factor: 3.478

6.  1064 nm Q switched Nd: YAG laser treatment of nevus of Ota: an Indian open label prospective study of 50 patients.

Authors:  Hemanta Kumar Kar; Lipy Gupta
Journal:  Indian J Dermatol Venereol Leprol       Date:  2011 Sep-Oct       Impact factor: 2.545

7.  Treatment of nevus of Ota with autologous-cultured epithelium grafting combined with dermabrasion.

Authors:  N Kumagai; S Fukushi; K Matsuzaki; H Ishida
Journal:  Ann Plast Surg       Date:  1995-02       Impact factor: 1.539

8.  Natural history of nevus of Ota.

Authors:  A Hidano; H Kajima; S Ikeda; H Mizutani; H Miyasato; M Niimura
Journal:  Arch Dermatol       Date:  1967-02

9.  QYAG5 Q-switched Nd:YAG Laser Treatment of Nevus of Ota: An Indian Study of 50 Patients.

Authors:  Sanjeev Aurangabadkar
Journal:  J Cutan Aesthet Surg       Date:  2008-07

10.  Treatment of nevus of Ota with the Q-switched ruby laser.

Authors:  S Watanabe; H Takahashi
Journal:  N Engl J Med       Date:  1994-12-29       Impact factor: 91.245

View more
  6 in total

1.  Comparing the efficacy and safety of Q-switched and picosecond lasers in the treatment of nevus of Ota: a systematic review and meta-analysis.

Authors:  Natalie M Williams; Pooja Gurnani; Jun Long; John Reynolds; Yue Pan; Takahiro Suzuki; Ghadah I Alhetheli; Keyvan Nouri
Journal:  Lasers Med Sci       Date:  2020-08-24       Impact factor: 3.161

2.  A study on the clinical characteristics of treating nevus of Ota by Q-switched Nd:YAG laser.

Authors:  Liu Yan; Li Di; Wang Weihua; Liu Feng; Li Ruilian; Zhou Jun; Su Hui; Ying Zhaoxia; Zeng Weihui
Journal:  Lasers Med Sci       Date:  2017-10-07       Impact factor: 3.161

3.  A split-face comparison of Q-switched Nd:YAG 1064-nm laser for facial rejuvenation in Nevus of Ota patients.

Authors:  Cao Yongqian; Lin Li; Bi Jianhai; Huo Ran; Guo Li; Wei Hao; Wang Xining; Xie Shigang; Wang Yibing
Journal:  Lasers Med Sci       Date:  2017-03-15       Impact factor: 3.161

4.  Assessment of the Response and Improving Outcomes of Nevus of Ota with Q-switched Nd : Yag Laser.

Authors:  Sanjeev J Aurangabadkar
Journal:  J Cutan Aesthet Surg       Date:  2013-10

Review 5.  Lasers and nevus of Ota: a comprehensive review.

Authors:  Vidhi V Shah; Fleta N Bray; Adam S Aldahan; Stephanie Mlacker; Keyvan Nouri
Journal:  Lasers Med Sci       Date:  2015-11-12       Impact factor: 3.161

6.  Usefulness of picosecond pulse alexandrite laser treatment for nevus of Ota.

Authors:  Reiko Sakio; Takafumi Ohshiro; Katsumi Sasaki; Toshio Ohshiro
Journal:  Laser Ther       Date:  2018-12-31
  6 in total