Literature DB >> 23639863

In vitro power profiles of daily disposable contact lenses.

Lurdes Belda-Salmerón1, David Madrid-Costa, Teresa Ferrer-Blasco, Santiago García-Lázaro, Robert Montés-Micó.   

Abstract

PURPOSE: To evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles.
METHODS: The Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5mm to 5.5mm in steps of 0.5mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2mm to 1.0mm in steps of 0.2mm).
RESULTS: All contact lenses showed an increase - more negative - in lens power with distance from the lens center. The amount of change varied depending on the lens. It was about 10% of lens power for DAILIES TOTAL1 (-0.29diopters (D)), SofLens daily disposable (-0.36D), and Proclear 1-Day (-0.32D) whereas 1-DAY ACUVUE MOIST showed a percentage variation of 3.3% (-0.10D). After inducing a lens decentration up to 1mm, the power curves were shifted in the negative direction. However, the change obtained in lens power compared with well-centered position was always lower than a quarter of diopter both for all the lenses and aperture diameters.
CONCLUSIONS: Our results showed a variation of the refractive power from the lens center, becoming more negative toward the periphery, with a negligible effect of the decentration for all disposable contact lenses studied.
Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Back vertex power; Contact lens; Daily disposable contact lens; Deflectometry; Power profile

Mesh:

Year:  2013        PMID: 23639863     DOI: 10.1016/j.clae.2013.03.007

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  4 in total

1.  In vitro optical quality of monofocal aspheric toric intraocular lenses: effect of cylindrical power.

Authors:  Teresa Ferrer-Blasco; Alberto Domínguez-Vicent; Santiago García-Lázaro; María Amparo Diez; José F Alfonso; José J Esteve-Taboada
Journal:  Int Ophthalmol       Date:  2017-04-25       Impact factor: 2.031

2.  Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses.

Authors:  Eleni Papadatou; Antonio J Del Águila-Carrasco; José J Esteve-Taboada; David Madrid-Costa; Alejandro Cerviño-Expósito
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

3.  Power Profiles of Commercial Multifocal Soft Contact Lenses.

Authors:  Eon Kim; Ravi C Bakaraju; Klaus Ehrmann
Journal:  Optom Vis Sci       Date:  2017-02       Impact factor: 1.973

4.  Reliability of power profiles measured on NIMO TR1504 (Lambda-X) and effects of lens decentration for single vision, bifocal and multifocal contact lenses.

Authors:  Eon Kim; Ravi C Bakaraju; Klaus Ehrmann
Journal:  J Optom       Date:  2015-11-14
  4 in total