Literature DB >> 23639366

The effects of cryoablation on renal cell carcinoma perfusion and glomerular filtration rate measured using dynamic contrast-enhanced MRI: a feasibility study.

S J Chapman1, T M Wah, S P Sourbron, D L Buckley.   

Abstract

AIM: To assess the effect of cryoablation on renal cell carcinoma (RCC) perfusion and single kidney (SK) glomerular filtration rate (GFR) using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI).
MATERIALS AND METHODS: Eighteen patients undergoing percutaneous cryoablation of a solitary RCC between August 2010 and November 2011 were evaluated with DCE-MRI immediately before and 1 month post-cryoablation. DCE-MRI data were acquired with 2 s temporal resolution in a coronal plane during the first pass of a 0.1 mmol/kg bolus dose of Gd-DOTA. Perfusion of the RCC (in ml/min/100 ml tissue) was estimated using a maximum slope technique. An index of SK GFR (SK-GFRi) was assessed using data acquired every 30 s for the following 3 min in the axial plane and analysed using Rutland-Patlak plots. This was compared to the GFR estimated by creatinine clearance (eGFR).
RESULTS: Perfusion in the zone of ablation decreased significantly (p<0.001) from a mean of 98.0 ± 37.5 ml/min/100 ml pre-cryoablation to 11.6 ± 4.1 ml/min/100 ml post-cryoablation; a mean decrease of 88.2%. Functional analysis was performed in seventeen patients. eGFR was underestimated by SK-GFRi which decreased significantly in tumour-bearing (-31.7%, p = 0.011), but not in contralateral kidneys (-4.4%, p = 0.14).
CONCLUSION: It is feasible to measure RCC perfusion pre- and post-cryoablation using DCE-MRI. The significant decrease within the zone of ablation suggests that this technique may be useful for assessment of treatment response. Further work is required to address the underestimation of eGFR by SK-GFRi and to validate the perfusion findings.
Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23639366     DOI: 10.1016/j.crad.2013.03.015

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

1.  Renal Cell Carcinoma Perfusion before and after Radiofrequency Ablation Measured with Dynamic Contrast Enhanced MRI: A Pilot Study.

Authors:  Tze Min Wah; Steven Sourbron; Daniel Jonathan Wilson; Derek Magee; Walter Martin Gregory; Peter John Selby; David L Buckley
Journal:  Diagnostics (Basel)       Date:  2018-01-08

2.  Modified dixon-based renal dynamic contrast-enhanced MRI facilitates automated registration and perfusion analysis.

Authors:  Anneloes de Boer; Tim Leiner; Eva E Vink; Peter J Blankestijn; Cornelis A T van den Berg
Journal:  Magn Reson Med       Date:  2017-11-13       Impact factor: 4.668

3.  Is there a role for perfusion imaging in assessing treatment response following ablative therapy of small renal masses-A systematic review.

Authors:  S J Withey; J Gariani; K Reddy; D Prezzi; C Kelly-Morland; S Ilyas; A Adam; V Goh
Journal:  Eur J Radiol Open       Date:  2018-07-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.