Evaluation of suction detection during different pumping states in an implantable rotary blood pump.

Siew-Cheok Ng1, Einly Lim, David G Mason, Alberto P Avolio, Nigel H Lovell.   

Abstract

In recent times, the problem of noninvasive suction detection for implantable rotary blood pumps has attracted substantial research interest. Here, we compare the performance of various suction indices for different types of suction and non-suction events based on pump speed irregularity. A total of 171 different indices that consist of previously proposed as well as newly introduced suction indices are tested using regularized logistic regression. These indices can be classified as amplitude based (derived from the mean, maximum, and minimum values of a cycle), duration based (derived from the duration of a cycle), gradient based (derived from the first order as well as higher order differences) and frequency based (derived from the power spectral density). The non-suction event data consists of ventricular ejection with or without arrhythmia and intermittent and continuous non-opening of the aortic valve. The suction event data consists of partial ventricular collapse that occurs intermittently as well as continuously with or without arrhythmia. In addition, we also attempted to minimize the usage of multiple indices by applying the sequential forward floating selection method to find which combination of indices gives the best performance. In general, the amplitude-based and gradient-based indices performed quite well while the duration-based and frequency-based indices performed poorly. By having only two indices ([i] the maximum gradient change in positive slope; and [ii] the standard deviation of the maximum value in a cycle), we were able to achieve a sensitivity of 98.9% and a specificity of 99.7%.
© 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

Entities:  

Keywords:  Implantable rotary blood pump; Pumping states; Suction detection

Mesh:

Year:  2013        PMID: 23635073     DOI: 10.1111/aor.12079

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  2 in total

1.  Continuous LVAD monitoring reveals high suction rates in clinically stable outpatients.

Authors:  Christoph Gross; Heinrich Schima; Thomas Schlöglhofer; Kamen Dimitrov; Martin Maw; Julia Riebandt; Dominik Wiedemann; Daniel Zimpfer; Francesco Moscato
Journal:  Artif Organs       Date:  2020-03-01       Impact factor: 3.094

2.  A Novel Control Method for Rotary Blood Pumps as Left Ventricular Assist Device Utilizing Aortic Valve State Detection.

Authors:  Dmitry Petukhov; Leonie Korn; Marian Walter; Dmitry Telyshev
Journal:  Biomed Res Int       Date:  2019-12-11       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.