Delaying the bath and in-hospital breastfeeding rates.

Genevieve Preer1, Jessica M Pisegna, John T Cook, Anne-Marie Henri, Barbara L Philipp.   

Abstract

BACKGROUND AND
OBJECTIVE: Until 2010, newborns at our institution were bathed in the nursery at approximately 2 hours of life. In May 2010, infant baths were delayed until at least 12 hours of life. Infants are now bathed in the hospital room with parents' participation and are placed skin-to-skin immediately after the bath. This study explored whether delaying the newborn's first bath correlates with increased in-hospital breastfeeding rates at our Baby-Friendly, urban safety-net hospital. SUBJECTS AND METHODS: We performed a retrospective chart review comparing in-hospital breastfeeding rates during the 6 months before and the 6 months after the bath was delayed.
RESULTS: Of the infants, 702 met inclusion criteria. Before the bath was delayed, infants were bathed at an average of 2.4 hours of life. Afterward, infants were bathed at an average of 13.5 hours of life. In-hospital exclusive breastfeeding rates increased from 32.7% to 40.2% (p<0.05) after the bath was delayed. Multivariate logistic regression analysis showed that infants born after implementation of delayed bathing had odds of exclusive breastfeeding 39% greater than infants born prior to the intervention (adjusted odds ratio [AOR]=1.39; 95% confidence interval [CI] 1.02, 1.91) and 59% greater odds of near-exclusive breastfeeding (AOR=1.59; 95% CI 1.18, 2.15). The odds of breastfeeding initiation were 166% greater for infants born after the intervention than for infants born before the intervention (AOR=2.66; 95% CI 1.29, 5.46).
CONCLUSIONS: In our cohort, a delayed newborn bath was associated with increased likelihood of breastfeeding initiation and with increased in-hospital breastfeeding rates.

Entities:  

Mesh:

Year:  2013        PMID: 23635002     DOI: 10.1089/bfm.2012.0158

Source DB:  PubMed          Journal:  Breastfeed Med        ISSN: 1556-8253            Impact factor:   1.817


  5 in total

1.  The impact on the exclusive breastfeeding rate at 6 months of life of introducing supplementary donor milk into the level 1 newborn nursery.

Authors:  Nawal Merjaneh; Patty Williams; Sandy Inman; Mandy Schumacher; Anuta Ciurte; Carmen Smotherman; Rana Alissa; Mark Hudak
Journal:  J Perinatol       Date:  2020-03-30       Impact factor: 2.521

2.  ABM Clinical Protocol #5: Peripartum breastfeeding management for the healthy mother and infant at term, revision 2013.

Authors:  Allison V Holmes; Angela Yerdon McLeod; Maya Bunik
Journal:  Breastfeed Med       Date:  2013-12       Impact factor: 1.817

Review 3.  Olfaction scaffolds the developing human from neonate to adolescent and beyond.

Authors:  Benoist Schaal; Tamsin K Saxton; Hélène Loos; Robert Soussignan; Karine Durand
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2020-04-20       Impact factor: 6.237

4.  Timing of first bath in term healthy newborns: A systematic review.

Authors:  Mayank Priyadarshi; Bharathi Balachander; Shuchita Gupta; Mari Jeeva Sankar
Journal:  J Glob Health       Date:  2022-08-17       Impact factor: 7.664

5.  The mPINC survey: Impacting US maternity care practices.

Authors:  Jennifer M Nelson; Daurice A Grossniklaus; Deborah A Galuska; Cria G Perrine
Journal:  Matern Child Nutr       Date:  2020-11-04       Impact factor: 3.092

  5 in total