Abstract

Structural allografts may be used to manage uncontained bone defects in revision total knee replacement (TKR). However, the availability of cadaver grafts is limited in some areas of Asia. The aim of this study was to evaluate the mid-term outcome of the use of femoral head allografts for the reconstruction of uncontained defects in revision TKR, focusing on complications related to the graft. We retrospectively reviewed 28 patients (30 TKRs) with Anderson Orthopaedic Research Institute (AORI) type 3 bone defects, who underwent revision using femoral head allografts and stemmed components. The mean number of femoral heads used was 1.7 (1 to 3). The allograft-host junctions were packed with cancellous autograft. At a mean follow-up of 76 months (38 to 136) the mean American Knee Society knee score improved from 37.2 (17 to 60) pre-operatively to 90 (83 to 100) (p < 0.001). The mean function score improved from 26.5 (0 to 50) pre-operatively to 81 (60 to 100) (p < 0.001). All the grafts healed to the host bone. The mean time to healing of the graft was 6.6 months (4 to 16). There have been no complications of collapse of the graft, nonunion, infection or implant loosening. No revision surgery was required. The use of femoral head allografts in conjunction with a stemmed component and autogenous bone graft in revision TKR in patients with uncontained bone defects resulted in a high rate of healing of the graft with minimal complications and a satisfactory outcome. Longer follow-up is needed to observe the evolution of the graft.

Entities:  

Mesh:

Year:  2013        PMID: 23632674     DOI: 10.1302/0301-620X.95B5.29915

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  8 in total

1.  No Difference Between Trabecular Metal Cones and Femoral Head Allografts in Revision TKA: Minimum 5-year Followup.

Authors:  Nemandra A Sandiford; Peter Misur; Donald S Garbuz; Nelson V Greidanus; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2017-01       Impact factor: 4.176

2.  Tantalum Cones Provide Durable Mid-term Fixation in Revision TKA.

Authors:  Ivan De Martino; Vincenzo De Santis; Peter K Sculco; Rocco D'Apolito; Joseph B Assini; Giorgio Gasparini
Journal:  Clin Orthop Relat Res       Date:  2015-05-13       Impact factor: 4.176

3.  Tibial bone loss in revision TKA: Options for management without sleeves and cones -a schematic review.

Authors:  Sibin Surendran; P Gopinathan
Journal:  J Orthop       Date:  2021-01-17

4.  Reply to the Letter to the Editor: No Difference Between Trabecular Metal Cones and Femoral Head Allografts in Revision TKA: Minimum 5-year Followup.

Authors:  Nemandra A Sandiford
Journal:  Clin Orthop Relat Res       Date:  2018-05       Impact factor: 4.176

5.  Can tibial tantalum cones eventually eliminate the adjuvant use of metallic augments for AORI type 2B/3 metaphyseal defects??-A novel surgical technique and case series.

Authors:  Mohit M Kukreja; Todd V Swanson
Journal:  Int J Surg Case Rep       Date:  2018-09-23

Review 6.  Management of bone loss in revision total knee arthroplasty: therapeutic options and results.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero; Carlos A Encinas-Ullán
Journal:  EFORT Open Rev       Date:  2021-11-19

7.  Application of structural allogenous bone graft in two-stage exchange arthroplasty for knee periprosthetic joint infection: a case control study.

Authors:  Chieh An Chuang; Sheng-Hsun Lee; Chih-Hsiang Chang; Chih-Chien Hu; Hsin-Nung Shih; Steve W N Ueng; Yuhan Chang
Journal:  BMC Musculoskelet Disord       Date:  2022-04-05       Impact factor: 2.362

8.  Bone Defects in Revision Total Knee Arthroplasty.

Authors:  Alan de Paula Mozella; Hugo Alexandre de Araújo Barros Cobra
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2020-09-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.