Literature DB >> 23632668

Ten-year RSA-measured migration of the Exeter femoral stem.

D W Murray1, A Gulati, H S Gill.   

Abstract

The Exeter femoral stem is a double-tapered highly polished collarless cemented implant with good long-term clinical results. In order to determine why the stem functions well we have undertaken a long-term radiostereometric analysis (RSA) study. A total of 20 patients undergoing primary Exeter total hip replacement for osteoarthritis using the Hardinge approach were recruited and followed with RSA for ten years. The stems progressively subsided and internally rotated with posterior head migration. The mean subsidence was 0.7 mm (95% confidence interval (CI) 0.5 to 0.9) at two years and 1.3 mm (95% CI 1.0 to 1.6) at ten years. The mean posterior migration of the head was 0.7 mm (95% CI 0.5 to 0.9) at two years and 1.2 mm (95% CI 1.0 to 1.4) at ten years. There was no significant cement restrictor migration. The Exeter stem continues to subside slowly into the cement mantle in the long term. This appears to compress the cement and the cement bone interface, contributing to secure fixation in the long term.

Entities:  

Mesh:

Year:  2013        PMID: 23632668     DOI: 10.1302/0301-620X.95B5.31330

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  10 in total

1.  Prospective, comparative study of cemented, smooth-surfaced titanium stems and polish-surfaced, stainless steel stems at a minimum follow-up of 10 years.

Authors:  Hiroshi Fujita; Hiroaki Hara; Hideto Harada; Masanao Kataoka; Tomohiro Tominaga; Ryuuichi Nishimura
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-11-18

2.  Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study.

Authors:  Marcus R Streit; Daniel Haeussler; Thomas Bruckner; Tanja Proctor; Moritz M Innmann; Christian Merle; Tobias Gotterbarm; Stefan Weiss
Journal:  Clin Orthop Relat Res       Date:  2016-04-29       Impact factor: 4.176

3.  Migration pattern of cemented Exeter short stem in Dorr type A femurs. A prospective radiostereometry study with 2-year follow-up.

Authors:  Tobias Dahl Vind; Peter Bo Jørgensen; Dovydas Vainorius; Stig Storgaard Jakobsen; Kjeld Søballe; Maiken Stilling
Journal:  Arch Orthop Trauma Surg       Date:  2022-02-03       Impact factor: 3.067

4.  Prospective two-year subsidence analysis of 100 cemented polished straight stems - a short-term clinical and radiological observation.

Authors:  Wolf Siepen; Lukas Zwicky; Karl Kilian Stoffel; Thomas Ilchmann; Martin Clauss
Journal:  BMC Musculoskelet Disord       Date:  2016-09-17       Impact factor: 2.362

5.  Excellent mid-term results of a new polished tapered modular cemented stem: a study of 113 hip replacements with minimum 5-year follow-up.

Authors:  Jens Vanbiervliet; Jan F A Somers
Journal:  Hip Int       Date:  2017-02-18       Impact factor: 2.135

6.  Equivalent hip stem fixation by Hi-Fatigue G and Palacos R + G bone cement: a randomized radiostereometric controlled trial of 52 patients with 2 years' follow-up.

Authors:  Peter B Jørgensen; Martin Lamm; Kjeld Søballe; Maiken Stilling
Journal:  Acta Orthop       Date:  2019-04-01       Impact factor: 3.717

7.  The design of the cemented stem influences the risk of Vancouver type B fractures, but not of type C: an analysis of 82,837 Lubinus SPII and Exeter Polished stems.

Authors:  Georgios Chatziagorou; Hans Lindahl; Johan Kärrholm
Journal:  Acta Orthop       Date:  2019-02-11       Impact factor: 3.717

8.  Cemented Exeter total hip arthroplasty with a 32 mm head on highly crosslinked polyethylene: Does age influence functional outcome, satisfaction, activity, stem migration, and periprosthetic bone mineral density?

Authors:  N D Clement; M Bardgett; K Merrie; S Furtado; R Bowman; D J Langton; D J Deehan; J Holland
Journal:  Bone Joint Res       Date:  2019-07-05       Impact factor: 5.853

9.  Is the French Paradox cementing philosophy superior to the standard cementing? A randomized controlled radiostereometric trial and comparative analysis.

Authors:  Kirsti Sevaldsen; Otto Schnell Husby; Øystein Bjerkestrand Lian; Kamel Mohamed Farran; Vigdis Schnell Husby
Journal:  Bone Joint J       Date:  2022-01       Impact factor: 5.082

Review 10.  Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review.

Authors:  Kwaku Baryeh; Jeewaka Mendis; David H Sochart
Journal:  EFORT Open Rev       Date:  2021-05-04
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.