Literature DB >> 23631969

Mechanical properties of Opus closing loops, L-loops, and T-loops investigated with finite element analysis.

Paiboon Techalertpaisarn1, Antheunis Versluis.   

Abstract

INTRODUCTION: The objective of this research was to investigate the mechanical properties at both sides of Opus closing loops by analyzing the effects of loop shape, loop position, coil position, and tipping of the vertical legs.
METHODS: Opus loops were compared with L-loops (with and without a coil) and a T-loop by using finite element analysis. Both upright and tipped vertical loop legs (70°) were tested. Loop response to loop pulling was simulated at 5 loop positions for a 12-mm interbracket distance and 10-mm loop lengths and heights. Three-dimensional models of the closing loops were created by using beam elements with stainless steel properties. The L-loops and Opus loops were directed toward the anterior side. Loop properties (horizontal load/deflection, vertical force, and moment-to-force ratio) at both loop ends were recorded at activation forces of 100 and 200 g.
RESULTS: Upright Opus loops and L-loops showed the highest moment-to-force ratios (8.5-9.3) on the canine bracket when the loop was centered. The Opus loops and L-loops with tipped vertical legs and the T-loop had slightly lower moment-to-force ratios (7.8-8.5), with the maximum values occurring when the loop was placed close to the canine bracket end.
CONCLUSIONS: Upright L-loops showed the highest moment-to-force ratios on canine brackets, whereas backward tipping of the vertical legs shifted mechanical properties closer to those of a T-loop. Loop properties varied with loop configuration and position. Clinicians should understand the specific characteristics of each loop configuration to most effectively exploit them for the desired tooth movements.
Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23631969     DOI: 10.1016/j.ajodo.2013.01.011

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Comparative assessment of the efficacy of closed helical loop and T-loop for space closure in lingual orthodontics-a finite element study.

Authors:  Ajay Chacko; Tripti Tikku; Rohit Khanna; Rana Pratap Maurya; Kamna Srivastava
Journal:  Prog Orthod       Date:  2018-05-28       Impact factor: 2.750

2.  Mechanical force system of double key loop with finite element analysis.

Authors:  Jiali Liu; Duanqiang Zhang; Linyu Xu; Senxin Cai; Jinquan Guo; Jiang Chen; Jiehua Su
Journal:  BMC Oral Health       Date:  2021-06-13       Impact factor: 2.757

3.  Effect of activation and preactivation on the mechanical behavior and neutral position of stainless steel and beta-titanium T-loops.

Authors:  Saúl Matos de Castro; Rui Moreira; Ana Cristina Braga; Afonso Pinhão Ferreira; Maria Cristina Pollmann
Journal:  Korean J Orthod       Date:  2015-07-24       Impact factor: 1.372

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.