| Literature DB >> 23630605 |
Yi Luo1, Xu Yan, Na Qi, Xiaodong Wang, Liangjiang Wang.
Abstract
Double-side replication of polymer substrates is beneficial to the design and the fabrication of 3-demensional devices. The ultrasonic embossing method is a promising, high efficiency and low cost replication method for thermoplastic substrates. It is convenient to apply silicon molds in ultrasonic embossing, because microstructures can be easily fabricated on silicon wafers with etching techniques. To reduce the risk of damaging to silicon molds and to improve the replication uniformity on both sides of the polymer substrates, thermal assisted ultrasonic embossing method was proposed and tested. The processing parameters for the replication of polymethyl methacrylate (PMMA), including ultrasonic amplitude, ultrasonic force, ultrasonic time, and thermal assisted temperature were studied using orthogonal array experiments. The influences of the substrate thickness, pattern style and density were also investigated. The experiment results show that the principal parameters for the upper and lower surface replication are ultrasonic amplitude and thermal assisted temperature, respectively. As to the replication uniformity on both sides, the ultrasonic force has the maximal influence. Using the optimized parameters, the replication rate reached 97.5% on both sides of the PMMA substrate, and the cycle time was less than 50 s.Entities:
Mesh:
Substances:
Year: 2013 PMID: 23630605 PMCID: PMC3632598 DOI: 10.1371/journal.pone.0061647
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Three patterns on the photo mask for fabricate silicon mold.
The dimensions of the micro patterns for different molds.
| Item | Longitudinal-stripe style | Diagonal-strip style | Checked style | |||
| Mold number | No. 1 | No. 2 | No. 3 | No. 4 | No. 5 | No. 6 |
| Pitch (µm) | 140 | 280 | 560 | 140 | 560 | 140 |
| Width (µm) | 70 | 70 | 70 | 70 | 70 | 70 |
Figure 2Thermal assisted ultrasonic embossing system.
Figure 3Thermal assisted ultrasonic embossing (a) schematic process; (b) the force and amplitude in an ultrasonic embossing process.
Results of the orthogonal experiments.
| No. | Thermal assisted temperature (°C) | Ultrasonic amplitude (µm) | Ultrasonic time (s) | Ultrasonic force (N) | Depth of the micro structures on PMMA substrate (µm) | |
| Upper surface | Lower surface | |||||
| 1 | 50 | 9.0 | 19 | 300 | 0.18 | 1.95 |
| 2 | 50 | 7.8 | 22 | 400 | 0.12 | 0.28 |
| 3 | 50 | 9.6 | 16 | 350 | 0.49 | 6.57 |
| 4 | 50 | 8.4 | 25 | 250 | 1.75 | 2.35 |
| 5 | 55 | 9.0 | 25 | 350 | 20.70 | 20.75 |
| 6 | 55 | 7.8 | 16 | 250 | 0.22 | 0.94 |
| 7 | 55 | 9.6 | 22 | 300 | 10.52 | 20.71 |
| 8 | 55 | 8.4 | 19 | 400 | 0.27 | 2.38 |
| 9 | 60 | 7.8 | 25 | 300 | 0.42 | 6.82 |
| 10 | 60 | 9.0 | 16 | 400 | 0.57 | 11.84 |
| 11 | 60 | 8.4 | 22 | 350 | 2.53 | 10.05 |
| 12 | 60 | 9.6 | 19 | 250 | 20.72 | 20.67 |
| 13 | 65 | 7.8 | 19 | 350 | 0.56 | 14.83 |
| 14 | 65 | 9.0 | 22 | 250 | 20.78 | 20.77 |
| 15 | 65 | 8.4 | 16 | 300 | 1.83 | 14.52 |
| 16 | 65 | 9.6 | 25 | 400 | 20.72 | 20.65 |
Figure 4The temperature testing system (a) schematic of the system; (b) position of the thermocouples.
Figure 5The temperature curve on both sides of the PMMA substrate in embossing.
The analysis of variance results of embossing parameters.
| Parameters | F-test value | ||
| Replication depth on the upper surface | Replication depth on the lower surface | Uniformity of the replication on both sides of PMMA substrate | |
| Thermal assisted temperature | 1.878 | 5.270 | 0.421 |
| Ultrasonic amplitude | 4.060 | 4.030 | 1.840 |
| Ultrasonic time | 1.899 | 0.647 | 2.864 |
| Ultrasonic force | 1.031 | 0.422 | 2.339 |
Figure 6The relationship between embossing parameters (a) replication rate; (b) replication uniformity.
Figure 7SEM images of embossed microstructure (a) longitudinal-stripe style; (b) checked style.
Replication results of 1 mm PMMA substrate.
| Thermal assisted temperature (°C) | Ultrasonic amplitude (µm) | Ultrasonic time (s) | Ultrasonic force (N) | Depth of the micro structures on PMMA substrate (µm) | |
| Upper surface | Lower surface | ||||
| 60 | 8.4 | 17 | 350 | 20.73 | 20.72 |
| 60 | 9.0 | 14 | 350 | 21.28 | 20.68 |
Figure 8Stress distribution in the substrates with different thickness(a) 1 mm PMMA substrate; (b) 2 mm PMMA substrate.
The embossing parameters and replication depth with different molds.
| Mold | Experiments number | Thermal assisted temperature (°C) | Ultrasonic amplitude (µm) | Ultrasonic time (s) | Ultrasonic force (N) | Depth of the micro structures on PMMA substrate (µm) | |
| Upper surface | Lower surface | ||||||
| Group A (upper mold No. 2, lower mold No. 3) | A1 | 60 | 8.4 | 22 | 350 | 13.02 | 20.78 |
| A2 | 60 | 7.8 | 25 | 300 | 20.68 | 20.40 | |
| A3 | 65 | 9.0 | 22 | 250 | 20.46 | 20.79 | |
| Group B (upper mold No. 2, lower mold No. 1) | B1 | 60 | 8.4 | 22 | 350 | 0.94 | 0.14 |
| B2 | 60 | 7.8 | 25 | 300 | 3.47 | 1.30 | |
| B3 | 65 | 9.0 | 22 | 250 | 20.61 | 20.81 | |
| Group C (upper mold No. 1, lower mold No. 1) | C1 | 60 | 8.4 | 22 | 350 | 0.35 | 0.68 |
| C2 | 60 | 7.8 | 25 | 300 | 0.21 | 0.47 | |
| C3 | 65 | 9.0 | 22 | 250 | 0.40 | 15.10 | |
| C4 | 65 | 9.6 | 25 | 400 | 21.01 | 20.79 | |
| Group D (upper mold No. 3, lower mold No. 3) | D1 | 60 | 8.4 | 22 | 350 | 0.71 | 19.85 |
| D2 | 60 | 7.8 | 25 | 300 | 0.23 | 11.18 | |
| D3 | 65 | 9.0 | 22 | 250 | 20.76 | 20.80 | |
| Group E (upper mold No. 4, lower mold No. 4) | E1 | 60 | 8.4 | 22 | 350 | 0.20 | 4.28 |
| E2 | 60 | 7.8 | 25 | 300 | 0.04 | 0.83 | |
| E3 | 65 | 9.0 | 22 | 250 | 6.54 | 17.97 | |
| Group F (upper mold No. 5, lower mold No. 5) | F1 | 60 | 8.4 | 22 | 350 | 0.83 | 10.4 |
| F2 | 60 | 7.8 | 25 | 300 | 0.84 | 3.41 | |
| F3 | 65 | 9.0 | 22 | 250 | 20.55 | 20.61 | |
| Group G (upper mold No. 6, lower mold No. 6) | G1 | 60 | 8.4 | 22 | 350 | 0.07 | 0.29 |
| G2 | 60 | 7.8 | 25 | 300 | 0.25 | 0.68 | |
| G3 | 65 | 9.0 | 22 | 250 | 0.30 | 15.34 | |
| G4 | 65 | 9.6 | 25 | 400 | 21.01 | 21.17 | |
The width and pitch of each mold was listed in Table 1.