Robert W Alexander1, David B Harrell. 1. Department of Surgery, School of Medicine and Dentistry, University of Washington, Seattle, WA, USA.
Abstract
OBJECTIVES: Provide background for use of acquiring autologous adipose tissue as a tissue graft and source of adult progenitor cells for use in cosmetic plastic surgery. Discuss the background and mechanisms of action of closed syringe vacuum lipoaspiration, with emphasis on accessing adipose-derived mesenchymal/stromal cells and the stromal vascular fraction (SVF) for use in aesthetic, structural reconstruction and regenerative applications. Explain a proven protocol for acquiring high-quality autologous fat grafts (AFG) with use of disposable, microcannula systems. DESIGN: Explain the components and advantage of use of the patented super luer-lock and microcannulas system for use with the closed-syringe system. A sequential explanation of equipment selection for minimally traumatic lipoaspiration in small volumes is presented, including use of blunt injection cannulas to reduce risk of embolism. RESULTS: Thousands of AFG have proven safe and efficacious for lipoaspiration techniques for large and small structural fat grafting procedures. The importance and advantages of gentle harvesting of the adipose tissue complex has become very clear in the past 5 years. The closed-syringe system offers a minimally invasive, gentle system with which to mobilize subdermal fat tissues in a suspension form. Resulting total nuclear counting of undifferentiated cells of the adipose-derived -SVF suggests that the yield achieved is better than use of always-on, constant mechanical pump applied vacuum systems. CONCLUSION: Use of a closed-syringe lipoaspiration system featuring disposable microcannulas offers a safe and effective means of harvesting small volumes of nonmanipulated adipose tissues and its accompanying progenitor cells within the SVF. Closed syringes and microcannulas are available as safe, sterile, disposable, compact systems for acquiring high-quality AFG. Presented is a detailed, step-by-step, proven protocol for performing quality autologous structural adipose transplantation.
OBJECTIVES: Provide background for use of acquiring autologous adipose tissue as a tissue graft and source of adult progenitor cells for use in cosmetic plastic surgery. Discuss the background and mechanisms of action of closed syringe vacuum lipoaspiration, with emphasis on accessing adipose-derived mesenchymal/stromal cells and the stromal vascular fraction (SVF) for use in aesthetic, structural reconstruction and regenerative applications. Explain a proven protocol for acquiring high-quality autologous fat grafts (AFG) with use of disposable, microcannula systems. DESIGN: Explain the components and advantage of use of the patented super luer-lock and microcannulas system for use with the closed-syringe system. A sequential explanation of equipment selection for minimally traumatic lipoaspiration in small volumes is presented, including use of blunt injection cannulas to reduce risk of embolism. RESULTS: Thousands of AFG have proven safe and efficacious for lipoaspiration techniques for large and small structural fat grafting procedures. The importance and advantages of gentle harvesting of the adipose tissue complex has become very clear in the past 5 years. The closed-syringe system offers a minimally invasive, gentle system with which to mobilize subdermal fat tissues in a suspension form. Resulting total nuclear counting of undifferentiated cells of the adipose-derived -SVF suggests that the yield achieved is better than use of always-on, constant mechanical pump applied vacuum systems. CONCLUSION: Use of a closed-syringe lipoaspiration system featuring disposable microcannulas offers a safe and effective means of harvesting small volumes of nonmanipulated adipose tissues and its accompanying progenitor cells within the SVF. Closed syringes and microcannulas are available as safe, sterile, disposable, compact systems for acquiring high-quality AFG. Presented is a detailed, step-by-step, proven protocol for performing quality autologous structural adipose transplantation.
For many years, cosmetic plastic surgeons have recognized the value of low-pressure
lipoaspiration for successful transplantation of adipose tissue for structural augmentation. In the
introductory years (1980–1990) of liposuction techniques, autologous fat grafting (AFG) was
considered unpredictable. Once bioengineers discovered the actual mechanisms by which lipoaspiration
worked, the closed syringe system for gentle harvesting and transplantation was developed and
patented. Early belief that effective lipoaspiration was directly related to force of vacuum was
replaced by understanding, that, introduction of fluid into the fat layers permitted the adipocyte
cells and stroma elements to enter into suspension. This suspension was easily extracted through use
of closed syringes, and provided adipose tissues with reduced damage and improved grafting
results.1In the mid-1980s, the importance of tumescent fluid distribution was first appreciated, and more
value was placed on extensive pre-tunneling (moving cannula without applying vacuum). This technique
better distributes local solution and enhances the ability to mobilize the adipose tissues into a
suspension state, which yields more successful and predictable autologous fat grafts (AFG).1In the early 2000s, appreciation of the potential of adipose tissue and its related stromal
elements led to examination of the adipose-derived adult mesenchymal stem cell content
(AD-MSC).2,3 Evidence has clearly shown the key importance of the progenitor cells
(SVF) and extracellular matrix (ECM) as integral contributors to the tissue maintenance and healing
processes.4 Studies of adipocyte replenishment
(following normal senescence and cellular death) showed that these attached progenitor cells were
activated to form adipocytes and thereby maintain adipose tissue integrity over time.5,6
Since there is easy accessibility and greater availability of multipotent progenitor cells for all
mesogenic lines within adipose tissues, utilization of AD-MSC/SVF has become a central focus in
optimizing effectiveness of autologous fat acquisition and grafting in cosmetic plastic surgery and
clinical regenerative medicine.7–10Preclinical and clinical applications have been reported in many scientific studies in the
biological, bioengineering, and clinical medical literature.11 Cosmetic plastic surgeons initially focused on understanding the
mechanisms to achieve safe and effective AFG. It was believed that intact cellular (mature
adipocytes) transplantation was the most important goal.12 However, it has become crystal clear that mature adult adipocytes transplanted may be the
least important feature producing long-term success, even in structural fat augmentation graft
applications. Current beliefs are that success in long-term AFG is actually due to activation of
adherent progenitor cells (attached to mature adipocytes, ECM and SVF), and proliferation of those
progenitor cells to differentiate into the target cell for replacement.4,13–15As an example, placement of lipoaspirants into existing adipose tissue favors proliferation and
differentiation into adipose cell phenotypes. As understanding of the maintenance (homeostatic) and
replenishment of adipose cell cycles in vivo increases, extensive research has been devoted to the
study of microenvironment (niche), cell-to-cell/cell-to-matrix factors, and autocrine/paracrine
signaling system functions. Since AD-MSC/SVF are capable of differentiation for all mesogenic lines,
including: 1) chondrogenic; 2) fibro-muscular (including tendon, ligament, and skeletal and cardiac
muscle); 3) osteogenic; and 4) adipogenic cell lines, uses in clinical applications have
increased.16–22Rapidly accumulating clinical data on the safety and efficacy of AD-MSC/SVF in vivo provides
clear evidence that adipose tissue grafts possess extensive potentials in wound healing, well beyond
the structural augmentation in cosmetic plastic surgical uses.Understanding these mechanisms results in important application potentials for aesthetic,
reconstructive, and regenerative medicine. Reporting of preclinical, early clinical, and controlled
studies in animal and human models shows worldwide recognition of the potential uses of these cells
in diverse areas of medicine and surgery.23–25
AFG as heterogeneous stromal-stem cell source and living bioscaffolding for use in aesthetic
reconstructive surgery
Research and clinical applications have led to appreciation of the existence of a large
heterogeneous, undifferentiated nucleated cell populations and extensive native bioactive
scaffolding that is an integral component of the total SVF components within the adipose
tissues.4Most reports examining the nature and components of the stromal vascular fraction (SVF) have come
from decades of study on bone marrow-derived stem cells (BM-SCs).26 It is now recognized that AD-MSCs have essentially the same
capabilities while offering significant advantages over BM-MSCs utilization. These include: 1) very
similar progenitor differentiation capabilities; 2) important cellular subsets (such as mesenchymal
and perivascular cells) are found in much higher concentrations compared to bone marrow aspirants
(>1500X); 3) less expensive to harvest; 4) less invasive (safer); 5) readily available tissue;
and 6) less technically demanding than bone marrow penetration and cellular harvest. These features
have led to increased uses in many areas of medicine and surgery.27–33With identification of the near-terminally differentiated cells (pre-adipocytes) attached
directly to the cytoplastic surface of all mature adipocytes by Granneman et al, homeostatic
mechanisms with adipose metabolism have been better understood.34 With advanced understanding of the processes of homeostatic adipose
replacement, many reasons why carefully harvested autologous fat grafts for structural augmentation
is effective have become much more predictable and understood than in years past.35–37Technology is now available to effectively isolate/concentrate these progenitor cells, but such
manipulation involving chemical digestion is not permitted for clinical use within the US.
Therefore, utilization of non-manipulated AFG/PRP concentrates remains the only option at this time.
With recognition that lipoaspiration (versus en bloc excised fat) acquires a bit over 50% of
the native multipotent, nucleated cell populations, such isolation and concentration protocols have
gained favor in efforts to help restore the multipotent cell numbers to near native levels.38 At this time, such digestion and isolation procedures
are prohibited by the regulatory agencies within the US, as they are considered more-than-minimally
manipulated tissues and subject to such rules.Laboratory findings suggest that use of closed-syringe harvesting techniques produces higher
nucleated cellular counts as compared with low-pressure wall suction or detuned lipoaspiration
mechanical pumps (Alexander RW, Mandle R; Harvard Biosciences Laboratory, unpublished data, 2012)
(See Figure 1).
Figure 1
Comparison of syringe-harvested isolated adipose-derived mesenchymal stromal cell (AD-MSC) counts
(open circles) versus use of low-pressure machine harvest (wall suction or detuned lipoaspiration
machine [dark circles]).
Notes: Vertical axis shows AD-MSCs per cc. Microcannula lipoaspirants were harvested
by offset 2.1 mm OD cannulas and processed by collagenase digestion to isolate cellular subsets;
counts were based on MSC-specific cell-marker characterization.
Abbreviation: OD, outside diameter.
The patented Tulip™ closed-syringe system (Tulip Medical Systems, San Diego, CA, USA),
with its array of microcannulas (small volumes-,100 cc) and standard volume reduction cannulas (for
>100 cc liporeduction and contouring), is a recognized and proven lipoaspiration system.
Explanation and detailed discussion of a repeatable, effective, and safe protocol for adipose tissue
complex harvest for cosmetic plastic surgeons will be provided in this paper.
Materials and methods
Selection of lipoaspiration sites
The lower abdomen and flank areas of both males and females are considered ideal adipose donor
sites due to distribution of human adipose tissues and relatively large deposits. Choice of
aspiration sites in the medial and lateral thigh/buttocks areas is sometimes favored for
lipoaspiration and adipose graft harvesting in female patients due to genetic distribution within
the gynoid body type. In patients with very low percentage body fat needing autologous grafts, use
of a high-definition ultrasound probe is helpful to determine the thickness and depth of adipose
deposits that can be acquired.
Preparation of lipoaspiration sites (donor and recipient)
The patients may be placed in either supine or lateral decubitus position to facilitate the
preparation and complete sterile isolation of the proposed donor area(s). It is considered important
to follow a standard sterile protocol for both the harvesting and placement sites. Routine operative
site asepsis should be maintained in all cases, with patients marked in an upright or standing
position to effectively mark the area of available or unwanted adipose tissue deposits.
Microcannula instrumentation
The patented Tulip™ closed-syringe system for lipoaspiration features very smooth
cannulas and a “super” luer-lock connection for use with standard luer-lock syringes
(Figure 2). This hub connection is a very important
component of the closed-syringe and microcannula system, in that it provides an excellent seal for
maintaining even vacuum forces desirable during lipoaspiration (Figure 3). Since the super-luer lock connection seals at both the
internal luer connection and at the outer ring of the standard luer connection, it thereby provides
a very stable, rigid base. Using microcannula sized instruments are very flexible compared to
standard cannula types. The super luer lok provides substantial stability and control in these
cases. Internal female luer-type connectors on some microcannula systems on the market become less
efficient when cannulas are redirected, placing a torque on the junction of cannula-syringe barrel,
and allowing air leakage into the closed system (particularly in the longer cannula selections).
This does not usually prevent aspiration capabilities, but it does decrease the efficiency and may
introduce cavitation to the harvest tissues.
Figure 2
Complete closed-syringe microcannula system (Tulip® GEMS™, Tulip
Medical Systems, San Diego, CA, USA).
Figure 3
Tulip® super luer-lock connection (Tulip Medical Systems, San Diego, CA,
USA).
Note: Seal on threaded standard luer connection (internal) plus seal on outside of
standard luer external hub.
Two standard options for microcannula selection offered within the Tulip™ system are:Cell-friendly microcannula option (autoclavable) (Figure
4). These cannulas are internally polished by microabrasive extrusion process to maximize
internal smoothness and reduce adipose tissue damage to the adipocytes, precursor cells, and their
accompanying matrix. External cannula anodizing processes provide a smoother surface for ease of
passage within the subdermal adipose plane. This is a popular design utilized by cosmetic plastic
surgeons for liporeduction as well as harvesting of AFG for structural augmentation procedures.
References the closed syringe system instruments are also available for larger volume liporeduction
(liposuction) cases and in large volume structural graft cases. In cannulas of less than 3.0 mm, it
is important to thoroughly flush with water-prep soap mix, followed by ultrasonic cleaning, and
thorough re-flushing with water prior to steam or gas sterilization.
Figure 4
Tulip® (Tulip Medical Systems, San Diego, CA, USA) cell-friendly
(autoclavable) microcannulas.
Sterile, coated disposable microcannula option (Figure
5). Use of disposable microcannulas in small diameters of less than 3.0 mm (range
0.9–2.4 mm outside diameter [OD]) presents a significant challenge to ensure
proper and effective cleaning–sterilization cycles. This makes a disposable option
attractive, particularly in the smaller diameter cannula group. These are packaged and labeled in a
sterile wrap, and can be opened directly onto the sterile field or back table. Featuring the super
luer-lock base, these stainless steel cannulas are totally coated internally and externally with a
hydrophilic material that provides an extremely smooth coating, which passes through adipose tissues
with minimal resistance and trauma. Initially, hydrogel coatings were applied on both internal and
external surfaces, but now have been replaced by more efficient and effective coating materials,
featuring more than 20 times more lubriciousness than previous coating materials. It is believed
that the least cellular and tissue trauma created, the better the quality of the adipose grafts.
Figure 5
Disposable microcannula cannulas for closed-syringe lipoaspiration of small-volume autologous
adipose grafting (Tulip® GEMS™, Tulip Medical Systems, San Diego, CA,
USA).
With increased recognition of difficulties in effectively cleaning the nondisposable
microcannulas (<3.0 mm), most surgeons and operating facilities are choosing use of completely
disposable infiltration, harvesting, and injection cannulas.
Selection of microcannula length and diameters
For small volume applications (<100 cc), it is recommended to use a small, multiport
infiltrator cannula for even and thorough distribution of local anesthesia throughout the adipose
donor layer. Openings near the tip are multiple and oriented for 360-degree distribution of the
tumescent local solution while moving through the subdermal fat layers. It is common for
practitioners to use this infiltration cannula in diameters of 2.1–2.4 mm OD and a length of
10–20 cm (Figure 6
[top]).
Harvesting cannulas are designed to actually acquire the adipose tissue grafts from the subdermal
fat plane, following the same pattern and location of local anesthesia distribution (Figure 6 [middle]).The openings on the harvesting cannulas are usually provided as inline or offset openings
(meaning in a nonlinear pattern near the tip of the cannula). These vary in diameter from 1.67 mm to
2.4 mm (OD), with a length of 10–20 cm. Selection of a slightly shorter harvesting cannula
compared to length of infiltrator makes it somewhat easier to remain within the local anesthesia
distribution areas in awake patients.Closed-system syringe locks are available in two options, an “external” and an
“internal” form. The external locks are specifically designed for use on Bectin
Dickinson Co. (Franklin Lakes, NJ, USA) or Monoject (Covidien-Kendall, Mansfield, MA, USA) 10/12 and
20 cc luer-lock syringes and 60 cc Toomey tip syringes to hold the syringe plunger in a fully drawn
position during the application of vacuum. Before application of vacuum by pulling the syringe
plunger to the desired level, it is essential to draw sterile saline fluid into the cannula to
completely displace all air within the system. When pulled and twisted into the locked position, the
edge of the lock engages the side of the plunger permitting the physician to apply even and gentle
vacuum pressure while moving the cannula through the tumesced adipose layer. The internal type lock,
called a snap lock, universally fits a range of different syringe sizes from various manufacturers.
(Figure 7).
Figure 7
Closed-syringe lock options.
Notes: Left: internal snap lock (disposable); right: external Johnnie Lok™
(reusable) Tulip® (Tulip Medical Systems, San Diego, CA, USA).
Anaerobic transfers (luer-to-luer) are utilized to facilitate loading of treatment syringes prior
to grafting procedures, and for optional use of additives to the grafts (such as combining platelet
concentrates [HD PRP] and adipose grafts into one syringe [Figure 5 (bottom)]). They are also useful for
transferring the treatment mix into syringe sizes of physician preference for injection and avoiding
undesirable exposure of the harvested graft to air (Figure
8). It is considered important to avoid excessive air exposure to grafts due to the potential
for contamination by airborne particles or pathogens. Techniques described as helpful in free lipid
removal (such as Telfa™ “rolling”; Johnson & Johnson, New Brunswick, NJ,
USA) are vulnerable to such contamination.
Figure 8
Anaerobic luer-to-luer transfer shown loading adipose graft to 1 cc treatment syringe.
A controlled aliquot injector gun is useful for placement of controlled 0.5 cc aliquots of graft
into the prepared tunnels and locations. When additives are added to the adipose tissue graft, the
density of the injection material may be increased (eg, use of HD PRP plus thrombin to provide rapid
release of platelet-derived growth factors and signal proteins). This may result in the physician
requiring more force to inject into the tissue site, or, to encounter sudden and uneven distribution
of desired small aliquots of graft with prepared tunnels associated with adipose matrix density
within the graft itself. Single-trigger pull provides exact volumes of solution to be placed with
less pressure required by the provider (Figure
9).
Figure 9
Mechanical injector gun (Tulip®, Tulip Medical Systems, San Diego, CA,
USA).
Recommended step-by-step protocol for performing closed system microcannula
lipoaspiration
It is recommended that the area of donor and recipient sites be outlined with the patient in
upright position and using a skin-marking pencil. This area will then be prepped, draped, and
isolated to expose the thickest deposit of palpable fat tissues, and serve as a distribution pattern
for local anesthetic infiltration (see Figure 10
for an example).
Figure 10
Example marking of lower abdomen site for harvesting of subdermal adipose tissue.
Note: Arrows show wheel-spoke pattern of tumescent infiltration and harvesting of
abdominal donor site.
After marking, preparation, and sterile isolation of the donor area, an 18–20 g beveled
needle is held such that the side edge is held vertical to the skin. This side edge is utilized to
create a small, vertical (slit-like) opening, extending through the epidermis and dermis into the
subdermal fat plane of the donor site. It is very important to avoid too large an opening, as
closed-syringe-system vacuum depends on maintaining a tight side wall opening to ensure even vacuum
application. Use of stab incisions with scalpel blades of #15 or #11 sizes tends to
create larger than necessary or desired openings. The opening is made larger by selectively cutting
the dermal layer (under the skin surface) with the edge of the needle bevel. In large cannula sizes,
use of a tapered stainless sharp trocar (3 mm) is utilized to permit a snug fit of the aspiration
cannulas into the desired space for cannulas of >3 mm OD. This allows the introduction of the
multiport infiltration cannula through the skin and the subdermal fascia (and in the anterior
abdominal wall example, should perforate and remain beneath Scarpa’s fascia) (Figure 11).
Figure 11
Placement of microcannula below Scarpa’s fascia in the adipose tissue plane.
Following entry, the multiport infiltrator cannula should be passed in a horizontal fashion
within deeper aspects of the subcutaneous donor fat deposit, above the muscular layer, in a
“spokes-of-a-wheel” pattern. Pinching the skin-fat tissues may help in passing the
cannula. During movement of the infiltrating cannula, very slow injection of tumescent local
anesthesia fluid, during both entry and withdrawal strokes improves even distribution. Placement in
layers, beginning in the deeper aspects, and moving to more superficial levels is most effective.
The importance of avoiding “pooling” of the tumescent local anesthesia is that
evenly distributing liquids improves the efficiency of harvest by providing a suspensory fluid
carrier for the adipose graft tissues, as well as excellent patient comfort. If tumescent fluids are
rapidly injected or injected only in a few locations within the fat deposits, pooling is often the
result. This pooling is recognized by the surgeon by the presence of larger amounts of infranatant
fluids seen after gravity decantation or centrifugation.In typical small volume grafting cases, use of tumescent local anesthesia in a range of
20–30 cc is common. As a general guideline, it is important to place at least 1 cc of
tumescent local per 1 cc of anticipated graft to be harvested. For example, if the plan is to
aspirate 50 cc of adipose tissues, then use of 50 cc or greater fluid volume is distributed with the
adipose layer to provide the fluid carrier for extraction of the grafts. A common example of the
component of tumescent solution is to add the contents of a 50 cc multidose vial of local anesthetic
(eg, 0.5% to 1.0% xylocaine with or without epinephrine [1:100,000])
to 1 L of sterile saline or balanced salt solution to provide sufficient tumescent fluid for
lipoaspiration.Upon completion of even distribution of tumescent fluid within the proposed donor area, it is
recommended that repetitive passage of the infiltrating cannula throughout the tumesced donor area
(termed “pre-tunneling”) multiple times is important and very helpful to attain an
even and high quality graft. This more thoroughly distributes local anesthetic fluid for patient
comfort, and it also provides the needed “carrier fluid” to effectively suspend the
adipose tissues prior to harvesting with low pressure and minimal bleeding. This is a very important
step that will improve comfort during harvest, plus make extraction more efficient and result in
markedly less volume of the unwanted infranatant fluid layer.In small-volume transfers, most practitioners select a 20 cc luer syringe attached to the
harvesting microcannula with a mounted locking device. A very small volume (1–2 cc) of
sterile 0.9% saline is drawn into the cannula to displace air from the system prior to
insertion into the harvest (donor site). This is termed “charging” the syringe
device, and is necessary to eliminate all air from within the cannula and syringe, thereby avoiding
cavitation produced when using mechanical pump suction devices (wall suction, detuned lipoaspiration
machines, etc).Once the harvesting cannula is inserted into the locally tumesced and pre-tunneled adipose layer,
the syringe plunger is drawn to partial or full extension depending on desired vacuum pressure, and
twisted to provide a “lock,” if using an external type, or a ledge, which snaps to
hold the plunger in one of three positions. After application of vacuum, the physician is free to
move the harvesting cannula in a forward and back series of passages. It is important that these
passages are within the same plane and of the same pattern used during the placement of tumescent
solution. Adipose return, at first, will be somewhat slower, as the graft tissue must be in
suspension to be able to be easily extracted. Continuing these movements with vacuum applied will
yield adipose tissues with minimal bleeding in most patients.During the displacement of air, it is recommended that 4 inch by 4 inch sterile gauze should be
held over the harvesting tip openings to avoid spraying contents. Occasionally, in cases where there
is a larger volume of infranatant fluid (the layer immediately below the fat tissues), simply
express the liquid portion, reinsert the harvesting cannula into the harvest site, lock the plunger,
and gather more graft tissue. In the event of vacuum pressure loss during the harvesting process, it
is sometimes necessary to completely remove the harvesting cannula from the donor site, carefully
expressing all air from within the cannula. When this is completed, reinsertion of the cannula is
performed, and vacuum is re-established by withdrawing (pulling) the plunger and re-locking it.The yellow adipose grafts will quickly gravity separate from the underlying (infranatant) fluid,
resulting in the graft floating on top of the small fluid volume within the syringe system. Test
tube/syringe stands or decanting stands are available to facilitate this initial gravity separation
(Figure 12A and B).
Figure 12
(A) Gravity decant base (luer); (B) gravity decant in test tube
rack.
Remember that a common cause of increased infranatant volume in the decanted syringe is
inadequate distribution of local fluid, creating a pooling effect, which reduces efficiency of
adipose harvest. It is for this reason that extensive pre-tunneling is highly recommended prior to
application of any vacuum to the tissues. Upon completion of aspiration of the desired graft volume,
the harvester cannula is removed, and the syringe end-capped and placed in a vertical position in a
standard test tube rack or directly mounted on a luer base of a decanting stand to allow gravity to
separate three distinct layers within the harvesting syringe. This usually requires decantation for
approximately 2–3 minutes or centrifugation (discussed below) at 1000 g for
3–4 minutes. After layer separation, practitioners expel the unwanted liquid layer
(infranatant liquid) on which the fat graft floats, which is expressed into sterile containers for
disposal.Following removal of the infranatant fluid layer, if additional graft is needed, it is possible
to reinsert the harvester into the donor site to acquire more graft tissue (adipocytes and
adipose-derived tissue stromal vascular fraction), additional decanting/centrifugation, followed by
anaerobic transfer loading of the graft into the treatment syringes of choice.When the desired volume is attained, lipoaspiration is completed, and the small opening is
covered with a triple antibiotic ointment and a Coverlet (BSN Medical, Charlotte, NC, USA) bandage
(adhesive on all sides).In the event of loss of vacuum (evidenced by a hissing sound), the cannula is simply removed from
the adipose tissues, fluid advanced into the harvesting cannula to eliminate air from the system,
cannula reinserted, and plunger pulled open and locked to restart the aspiration process.Ideally, the more thorough removal of unwanted fluids from the graft yields a more dense cellular
graft. It is important to effectively avoid the top layer (free lipid layer) from being included in
the final AFG transplantation. In addition, the free lipid layer (clear yellow liquid above the
harvested graft) should be avoided, as it is an irritant and prolongs the healing of the graft
tissues in that it must be removed during the process by macrophages, etc, over time.
Centrifugation option in AFG (recommended)
The desire to produce the best compact grafts with minimal remaining fluid excess has led many to
include use of optimal centrifugation (1000 g for 3–4 minutes) to
effectively compress the graft materials, help to more precisely separate fluid from harvested
graft, and facilitate removal of the unwanted free lipid component (Figure 13)39
“Several providers of tissue processing syringes offer the ability to more easily remove the
lipid layer from the graft tissues desired (see Figure
14). Whether by disk or weighted plunger, the free lipids are allowed to pass out of the
upper graft tissues and remain in the harvesting syringe itself. The ability to thoroughly remove
unnecessary fluid from the graft provides the surgeon an opportunity to avoid the mandatory
“overcorrection” needed due to the amount of remaining carrier fluids within the
graft. Further, use of a disposable separator disk, within the centrifuge processing syringe,
ensures more complete separation of the free lipid free lipid layer. Its removal prevents the
resulting irritation and inflammatory response when removing the unwanted additional free lipid from
within a recipient site (Figure 14).
Figure 13
The SmartPRep®2 APC+™centrifuge,
which forms part of the AdiPRep™ Adipose Transfer System (Harvest-Terumo, Plymouth, MA,
USA).
Note: The left syringe is the counterbalance (containing saline) and the right
contains the harvested adipose graft in a disposable processing syringe (with disk) prior to
centrifugation (1000 g for 4 minutes).
Figure 14
Close-up of a disposable processing syringe containing extracted tissue that has separated.
Notes: The top layer is free lipid in and above the white separator disk, the middle
layer is compressed adipose tissue graft, and the bottom layer is infranatant fluid and debris.
Some practitioners perform one to two rinses with sterile saline to help reduce any residual
local anesthetic solution and red blood cells.40After decantation and/or centrifugation steps, the graft preparation is ready for placement into
treatment syringes of physician’s choice. It is important to use clear anaerobic transfers
(luer-to-luer connectors) to load the individual application syringes from the prepared, compressed
graft (Figure 15). They are advantageous in that
they prevent external air exposure and potential for contamination and permit use of additives, such
as high-density platelet-rich plasma (HD PRP) concentrates. Use of HD PRP concentrates are believed
to further enhance the healing, graft acceptance, and provide high concentrations of helpful growth
factors and signal proteins.
Figure 15
Anaerobic transfer from disposable processing syringe (above) to adipose fat graft syringe
(below).
Treatment-standard luer syringes are then mounted with the desired injection cannulas, using
coated, single-port cannulas or the surgeons, preferred injector needles. Use of blunt-tip, coated
cannulas is recommended, particularly within the facial recipient areas to lower the risk of
embolism caused by inadvertent injection of the adipose graft intravascularly. The injection
cannulas are available in a variety of lengths and diameters (ranging from 0.9 mm to 1.47 mm OD), to
accommodate the surgeon’s preference and specific areas to be grafted. Some elect to inject
with sharp needles ranging in size from 18 g to 25 g (Figure 16).
Figure 16
Tulip® GEMS™ (Tulip Medical Systems, San Diego, CA, USA) single-port
injection cannulas (top) and close-up of the tip of one of these (bottom).
The typical graft recipient bed is prepared and developed by pre-tunneling to create a
“potential” space, which is subsequently filled in small aliquots and in layers as
the injection cannula is being withdrawn.It is recommended that the donor sites be dressed in a proper fashion. Use of small, sterile
absorbing gauze dressing placed over the skin opening created to place the tumescent fluids into the
subdermal tissues. Further, use of compression and closed cell, medical grade foam
(TenderFoam™; T&N Industries, San Diego, CA, USA) will eliminate or
minimize post-harvest bruising of the donor area. It is believed that use of foam and compression
reduces the lymphatic dispersion of small amounts of red blood cells or breakdown pigments remaining
within the surgical harvest site in the form of bruising or discoloration. Firm compression of the
gauze and TenderFoam for 24–48 hours is typically effective (Figure 17A and B).
Figure 17
(A) Close-up of closed-cell compression foam (TenderFoam™; T&N
Industries, San Diego, CA, USA). (B) Foam in place prior to firm compression.
Discussion
When the mechanisms involved in liposuction technologies were recognized in the mid–late
1980s, the ability to provide small- and large-volume liposuction via the closed-syringe system was
proven safe and more predictable and effective. By use of low vacuum pressure and avoiding air
within the system, the closed syringe system improved the results of liporeduction surgery and
autologous fat grafting success. This included removal of significantly larger volumes in a single
session and reduction of deposits within the superficial plane. The ability to safely and
effectively reduce unwanted fat deposits, coupled with improved skin redraping resulted in improved
surgical outcomes. Besides volume implications, closed-syringe lipoaspiration launched the beginning
of more consistent and predictable autologous fat grafting procedures, with improved safety,
efficacy, and predictability within aesthetic surgical applications. Structural fat grafting,
utilizing the exact techniques described herein, has been completed many thousands of times by many
cosmetic plastic surgeons (Figure
18A–J).
Figure 18
Clinical examples. Lips (A) pre- and (B) 1-year post-augmentation
(autologous fat grafting [AFG] plus high-density platelet-rich plasma [HD
PRP] [upper lip 3 cc; lower lip 2 cc]). (C) Pre- and
(D) postoperative (20 months) AFG plus HD PRP grafting to lips, cheeks and nasolabial
folds (lips: upper 2.5 cc; lower 2 cc; cheeks: 5 cc bilateral, malar and sub-malar placement;
nasolabial folds: 3 cc bilateral). Cheeks (E and F) pre- and
(G and H) 2 years post-AFG plus HD PRP (bilateral cheeks; total volume
grafted, 5 cc bilateral malar and sub-malar) (Photos with permission). (I) Pre- and
(J) postoperative (4 years) large-volume augmentation of both breasts (closed-syringe
technique, cell-friendly cannulas) using AFG plus HD PRP concentrate; right, 300 cc; left, 325
cc).
Scientific research has now provided important information to help explain the homeostatic and
transplant acceptance mechanisms accomplished by autologous fat. As appreciation of the biocellular
nature of the adipose tissue complex increases, the importance and value of the SVF has gained major
attention.4The authors believe that high-quality, dense cellular grafts are very important to the
effectiveness of structural fat grafting procedures. To that end, ensurance of complete layer
separation of the harvested grafts provided by optimized centrifugation is considered advantageous.
In addition to use of such centrifugation, the use of a disposable processing syringe (with
separator disk) further ensures that free lipids are effectively removed during graft preparation.
The AdiPRep™ system (Harvest-Terumo, Plymouth, MA, USA) provides such a system using the
same centrifuge as used for producing HD PRP concentrates (SmartPRep II™; Harvest-Terumo,
Plymouth, MA, USA). Use of closed systems for the harvesting and preparation of high-quality grafts
is considered of great importance.It is becoming mainstream knowledge that the actual transplanted mature adipocytes are gradually
lost, while serving an important role in their own replacement from attached near-terminally
differentiated cells (pre-adipocytes). For several years, leading practitioners sought to achieve
pure, adipocyte grafts, without regard to the SVF components and the effects of the local
microenvironment available with the recipient fat tissues.The importance of signaling and growth factor secretion associated with certain paracrine
effects, have changed the treatment paradigm of small volume structural grafting. While it is now
clear that the loss of most of the mature adipocytes is inevitable, it is appreciated that they
still play an important integral role, as they participate in stimulation of the microenvironment,
within the associated stromal vascular fraction. The near-terminally differentiated pre-adipocytes
are activated to initiate their final differentiation into adipocytes and contribution to lipid
metabolism and volume storage. Further, it is now known that the cellular and extracellular matrix
(ECM) associated within the stromal elements serves an equally important role, serving as a living
bio-scaffold (attachment to adipocytes and SVF) that is critical in encouraging available
multipotent cells to effectively activate and proliferate. Both the AFG and additive effects are
further enhanced in the surgically damaged recipient tissues through complex
“signaling” mechanisms of autocrine and paracrine pathways in vivo.4,36
Conclusion
This paper presents a simple and effective method of lipoaspiration with which to harvest
adipocytes and their accompanying progenitor and stromal elements using a disposable, closed syringe
and microcannula system. Effective for lipoaspiration of small and large volumes, the use of a
closed-syringe system and its accessories offers a full range of options by which to fulfill all AFG
requirements. The safety and efficacy of using closed-syringe systems has evolved to the use of a
coated, disposable microcannula system specifically designed for use in structural autologous fat
harvest and transfer, which currently serves as the most complete and effective gold standard for
all closed-syringe systems.
Authors: Brian M Strem; Kevin C Hicok; Min Zhu; Isabella Wulur; Zeni Alfonso; Ronda E Schreiber; John K Fraser; Marc H Hedrick Journal: Keio J Med Date: 2005-09
Authors: Patricia A Zuk; Min Zhu; Peter Ashjian; Daniel A De Ugarte; Jerry I Huang; Hiroshi Mizuno; Zeni C Alfonso; John K Fraser; Prosper Benhaim; Marc H Hedrick Journal: Mol Biol Cell Date: 2002-12 Impact factor: 4.138
Authors: Linda L Black; James Gaynor; Dean Gahring; Cheryl Adams; Dennis Aron; Susan Harman; Daniel A Gingerich; Robert Harman Journal: Vet Ther Date: 2007
Authors: L Aust; B Devlin; S J Foster; Y D C Halvorsen; K Hicok; T du Laney; A Sen; G D Willingmyre; J M Gimble Journal: Cytotherapy Date: 2004 Impact factor: 5.414
Authors: Perry Liu; Binay Gurung; Irrum Afzal; Matteo Santin; David H Sochart; Richard E Field; Deiary F Kader; Vipin Asopa Journal: J Exp Orthop Date: 2022-10-09
Authors: John R Koethe; Wyatt McDonnell; Arion Kennedy; Chike O Abana; Mark Pilkinton; Ian Setliff; Ivelin Georgiev; Louise Barnett; Cindy C Hager; Rita Smith; Spyros A Kalams; Alyssa Hasty; Simon Mallal Journal: J Acquir Immune Defic Syndr Date: 2018-02-01 Impact factor: 3.731
Authors: Celestine N Wanjalla; Wyatt J McDonnell; Louise Barnett; Joshua D Simmons; Briana D Furch; Morgan C Lima; Beverly O Woodward; Run Fan; Ye Fei; Paxton G Baker; Ramesh Ram; Mark A Pilkinton; Mona Mashayekhi; Nancy J Brown; Simon A Mallal; Spyros A Kalams; John R Koethe Journal: Front Immunol Date: 2019-03-19 Impact factor: 7.561
Authors: Angelo Trivisonno; Robert W Alexander; Silvia Baldari; Steven R Cohen; Giuliana Di Rocco; Pietro Gentile; Guy Magalon; Jérémy Magalon; Randy B Miller; Hayley Womack; Gabriele Toietta Journal: Stem Cells Transl Med Date: 2019-10-10 Impact factor: 6.940
Authors: Curtis L Gabriel; Fei Ye; Run Fan; Sangeeta Nair; James G Terry; John Jeffrey Carr; Heidi Silver; Paxton Baker; LaToya Hannah; Celestine Wanjalla; Mona Mashayekhi; Sam Bailin; Morgan Lima; Beverly Woodward; Manhal Izzy; Jane F Ferguson; John R Koethe Journal: Hepatol Commun Date: 2021-02-27
Authors: Anne-Claire Girard; Sophie Mirbeau; Lydie Gence; Vincent Hivernaud; Pierre Delarue; Olivier Hulard; Franck Festy; Regis Roche Journal: Plast Reconstr Surg Glob Open Date: 2015-08-27