Literature DB >> 23625065

Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study.

N A Alsufyani1, M L Noga, W H Finlay, P W Major.   

Abstract

The purpose of this study is to explore the topical use of radiographic contrast agents to enhance soft-tissue contrast on cone beam CT (CBCT) images. Different barium sulphate concentrations were first tested using an airway phantom. Different methods of barium sulphate application (nasal drops, syringe, spray and sinus wash) were then tested on four volunteers, and nebulized iodine was tested in one volunteer. CBCT images were performed and then assessed subjectively by two examiners for contrast agent uniformity and lack of streak artefact. 25.0% barium sulphate presented adequate viscosity and radiodensity. Barium sulphate administered via nasal drops and sprays showed non-uniform collection at the nostrils, along the inferior and/or middle nasal meatuses and posterior nasal choana. The syringe and sinus wash showed similar results with larger volumes collecting in the naso-oropharynx. Nebulized iodine failed to distribute into the nasal cavity and scarcely collected at the nostrils. All methods of nasal application failed to adequately reach or uniformly coat the nasal cavity beyond the inferior nasal meatuses. The key factors to consider for optimum topical radiographic contrast in the nasal airway are particle size, flow velocity and radio-opacity.

Entities:  

Keywords:  administration; cone beam computed tomography; contrast agents; topical

Mesh:

Substances:

Year:  2013        PMID: 23625065      PMCID: PMC3699978          DOI: 10.1259/dmfr.20130022

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  13 in total

1.  Effect of scattered radiation on image noise in cone beam CT.

Authors:  M Endo; T Tsunoo; N Nakamori; K Yoshida
Journal:  Med Phys       Date:  2001-04       Impact factor: 4.071

2.  Radiographic comparison of three methods for nasal saline irrigation.

Authors:  David E L Olson; Barry M Rasgon; Raymond L Hilsinger
Journal:  Laryngoscope       Date:  2002-08       Impact factor: 3.325

Review 3.  Three-dimensional segmentation of the upper airway using cone beam CT: a systematic review.

Authors:  N A Alsufyani; C Flores-Mir; P W Major
Journal:  Dentomaxillofac Radiol       Date:  2012-05       Impact factor: 2.419

4.  Fatal aspiration of barium sulfate.

Authors:  C Buschmann; F Schulz; M Tsokos
Journal:  Forensic Sci Med Pathol       Date:  2010-07-06       Impact factor: 2.007

5.  A comparative study of three methods of nasal irrigation.

Authors:  Peter-John Wormald; Tim Cain; Lyndell Oates; Lianne Hawke; Ian Wong
Journal:  Laryngoscope       Date:  2004-12       Impact factor: 3.325

6.  Sinonasal distribution of topically applied particles: computerized tomographic detection and the effects of topical decongestion.

Authors:  Dogan Senocak; Mustafa Senocak; Serkan Bozan
Journal:  Otolaryngol Head Neck Surg       Date:  2005-12       Impact factor: 3.497

7.  Radiographic distribution of drops and sprays within the sinonasal cavities.

Authors:  Kelli L Rudman; Erin K O'Brien; Donald A Leopold
Journal:  Am J Rhinol Allergy       Date:  2011 Mar-Apr       Impact factor: 2.467

8.  Barium sulfate as contrast medium for evaluation of postoperative anastomotic leaks.

Authors:  W Tanomkiat; W Galassi
Journal:  Acta Radiol       Date:  2000-09       Impact factor: 1.990

9.  Does nasal irrigation enter paranasal sinuses in chronic rhinosinusitis?

Authors:  Kornkiat Snidvongs; Pattraporn Chaowanapanja; Songklot Aeumjaturapat; Supinda Chusakul; Puangmali Praweswararat
Journal:  Am J Rhinol       Date:  2008 Sep-Oct

10.  Usefulness of high-density barium for detection of leaks after esophagogastrectomy, total gastrectomy, and total laryngectomy.

Authors:  Jonathan O Swanson; Marc S Levine; Regina O Redfern; Stephen E Rubesin
Journal:  AJR Am J Roentgenol       Date:  2003-08       Impact factor: 3.959

View more
  2 in total

1.  Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects.

Authors:  Ambrose J Huang; Connie Y Chang; Bijoy J Thomas; Peter J MacMahon; William E Palmer
Journal:  Skeletal Radiol       Date:  2015-02-05       Impact factor: 2.199

Review 2.  Optimized imaging of the midface and orbits.

Authors:  Sönke Langner
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2015-12-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.