Literature DB >> 23624960

Intra-procedural imaging of the left atrium and pulmonary veins with rotational angiography: a comparison of anatomy obtained by pre-procedural cardiac computed tomography and trans-thoracic echocardiography.

Yae Min Park1, Mi Na Kim, Jong-Il Choi, Hong Euy Lim, Seong-Mi Park, Sang Weon Park, Wan Joo Shim, Young-Hoon Kim.   

Abstract

This study evaluated the feasibility and accuracy of three-dimensional rotational angiography (3DRA) to determine the anatomy of the left atrium (LA) and pulmonary veins (PVs) compared with cardiac computed tomography (CCT) and trans-thoracic echocardiography (TTE). One hundred two patients (56.1 ± 9.9 years, 86 males) with an indication for atrial fibrillation ablation were prospectively enrolled. Intra-procedural 3DRA was performed with power injected contrast medium (20 cc/s for 4 s, 240°) in the LA. 3DRA images of the LA and PVs were assessed qualitatively and then compared quantitatively. LA volume measured by 3DRA, CCT and TTE were compared. The majority of 3DRA acquisitions were optimal in delineating the right-side LA-PV (95 % for right superior PV and 96 % for right inferior PV) and left inferior PV anatomy (91 %), whereas it was optimal in only 63 % of left superior PV and 73 % of the LA appendage. The circumferences of PV ostia identified by 3DRA and CCT were correlated in four PVs (r = 0.57 for right superior PV, r = 0.67 for right inferior PV, r = 0.60 for left superior PV, and r = 0.52 for left inferior PV, p < 0.001). The mean LA volume measured by 3DRA (120 ± 32 mL) was greater than that found by CCT (109 ± 35 mL) or TTE (64 ± 23 mL), but the 3DRA LA volume measurements correlated well with those of CCT (r = 0.83, p < 0.001) and TTE (r = 0.69, p < 0.001). Intra-procedural 3DRA provided anatomical accuracy of LA and PVs comparable to those of CCT. However, optimal delineation of the left superior PV and LA appendage was limited. The LA volume determined by 3DRA was well correlated with those of CCT and TTE, despite different absolute values of each.

Entities:  

Mesh:

Year:  2013        PMID: 23624960     DOI: 10.1007/s10554-013-0230-x

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  25 in total

1.  Left atrial volume determination by biplane two-dimensional echocardiography: validation by cine computed tomography.

Authors:  B Kircher; J A Abbott; S Pau; R G Gould; R B Himelman; C B Higgins; M J Lipton; N B Schiller
Journal:  Am Heart J       Date:  1991-03       Impact factor: 4.749

2.  Adenosine-induced atrial arrhythmia: a prospective analysis.

Authors:  S A Strickberger; K C Man; E G Daoud; R Goyal; K Brinkman; B P Knight; R Weiss; M Bahu; F Morady
Journal:  Ann Intern Med       Date:  1997-09-15       Impact factor: 25.391

3.  Three-dimensional rotational angiography of the left atrium and esophagus--A virtual computed tomography scan in the electrophysiology lab?

Authors:  Michael V Orlov; Peter Hoffmeister; G Muqtada Chaudhry; Ibrahim Almasry; Geert H M Gijsbers; Tammee Swack; Charles I Haffajee
Journal:  Heart Rhythm       Date:  2006-10-13       Impact factor: 6.343

4.  First experience of 3D rotational angiography fusion with NavX electroanatomical mapping to guide catheter ablation of atrial fibrillation.

Authors:  Mahendra Carpen; John Matkins; George Syros; Maxim V Gorev; Zoubin Alikhani; John V Wylie; Shaw R Natan; Andre Griben; Amy Hicks; James Armstrong; Michael V Orlov
Journal:  Heart Rhythm       Date:  2012-11-17       Impact factor: 6.343

5.  Underestimation of left atrial volume by three-dimensional echocardiography validated by magnetic resonance imaging: a meta-analysis and investigation of the source of bias.

Authors:  Yuichi J Shimada; Takahiro Shiota
Journal:  Echocardiography       Date:  2011-12-09       Impact factor: 1.724

6.  Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: implications for catheter ablation of atrial fibrillation.

Authors:  Zachary J Malchano; Petr Neuzil; Ricardo C Cury; Godtfred Holmvang; Jiri Weichet; Ehud J Schmidt; Jeremy N Ruskin; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2006-11

7.  Intraprocedural volume imaging of the left atrium and pulmonary veins with rotational X-ray angiography: implications for catheter ablation of atrial fibrillation.

Authors:  Aravinda Thiagalingam; Robert Manzke; Andre D'Avila; Ivan Ho; Andrew H Locke; Jeremy N Ruskin; Raymond C Chan; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2007-11-12

8.  Left ventricular volumes determined by two-dimensional echocardiography in a normal adult population.

Authors:  D W Wahr; Y S Wang; N B Schiller
Journal:  J Am Coll Cardiol       Date:  1983-03       Impact factor: 24.094

9.  A new method for measurement of left atrial volumes using 64-slice spiral computed tomography: comparison with two-dimensional echocardiographic techniques.

Authors:  Luc Christiaens; Benoît Lequeux; Paul Ardilouze; Stephanie Ragot; Jean Mergy; Daniel Herpin; Benjamin Bonnet; Joseph Allal
Journal:  Int J Cardiol       Date:  2008-01-04       Impact factor: 4.164

10.  Image-integration of intraprocedural rotational angiography-based 3D reconstructions of left atrium and pulmonary veins into electroanatomical mapping: accuracy of a novel modality in atrial fibrillation ablation.

Authors:  Georg Nölker; Stefan Asbach; Klaus J Gutleben; Harald Rittger; Guido Ritscher; Johannes Brachmann; Anil M Sinha
Journal:  J Cardiovasc Electrophysiol       Date:  2009-10-05
View more
  2 in total

Review 1.  Cardiovascular imaging 2013 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2014-04       Impact factor: 2.357

Review 2.  Left atrial appendage closure devices.

Authors:  Jorge Romero; Irving E Perez; Andrew Krumerman; Mario J Garcia; Richard J Lucariello
Journal:  Clin Med Insights Cardiol       Date:  2014-06-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.