Literature DB >> 23624017

A compact hybrid-multiplexed potentiostat for real-time electrochemical biosensing applications.

Ioannis Ramfos1, Nikolaos Vassiliadis, Spyridon Blionas, Konstantinos Efstathiou, Alex Fragoso, Ciara K O'Sullivan, Alexios Birbas.   

Abstract

The architecture and design of a compact, multichannel, hybrid-multiplexed potentiostat for performing electrochemical measurements on continuously-biased electrode arrays is presented. The proposed architecture utilises a combination of sequential and parallel measurements, to enable high performance whilst keeping the system low-cost and compact. The accuracy of the signal readout is maintained by following a special multiplexing approach, which ensures the continuous biasing of all the working electrodes of an array. After sampling the results, a digital calibration technique factors out errors from component inaccuracies. A prototype printed circuit board (PCB) was designed and built using off-the-shelf components for the real-time measurement of the amperometric signal of 48 electrodes. The operation and performance of the PCB was evaluated and characterised through a wide range of testing conditions, where it exhibited high linearity (R(2)>0.999) and a resolution of 400pA. The effectiveness of the proposed multiplexing scheme is demonstrated through electrochemical tests using KCl and [Fe(CN)6](3-) in KCl solutions. The applicability of the prototype multichannel potentiostat is also demonstrated using real biosensors, which were applied to the detection of IgA antibodies.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23624017     DOI: 10.1016/j.bios.2013.03.068

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  An Efficient Power Harvesting Mobile Phone-Based Electrochemical Biosensor for Point-of-Care Health Monitoring.

Authors:  Alexander C Sun; Chengyang Yao; A G Venkatesh; Drew A Hall
Journal:  Sens Actuators B Chem       Date:  2016-05-06       Impact factor: 7.460

2.  Automated Multiplexed Potentiostat System (AMPS) for High-Throughput Characterization of Neural Interfaces.

Authors:  Travis L Massey; Jeremy R Gleick; Razi-Ul M Haque
Journal:  IEEE Biomed Circuits Syst Conf       Date:  2021-12-23

3.  A compact, low-cost, and binary sensing (BiSense) platform for noise-free and self-validated impedimetric detection of COVID-19 infected patients.

Authors:  Razieh Salahandish; Pezhman Jalali; Hamed Osouli Tabrizi; Jae Eun Hyun; Fatemeh Haghayegh; Mahmood Khalghollah; Azam Zare; Byron M Berenger; Yan Dong Niu; Ebrahim Ghafar-Zadeh; Amir Sanati-Nezhad
Journal:  Biosens Bioelectron       Date:  2022-06-14       Impact factor: 12.545

Review 4.  Paper-based analytical devices for environmental analysis.

Authors:  Nathan A Meredith; Casey Quinn; David M Cate; Thomas H Reilly; John Volckens; Charles S Henry
Journal:  Analyst       Date:  2016-03-21       Impact factor: 5.227

5.  Bi-ECDAQ: An electrochemical dual-immuno-biosensor accompanied by a customized bi-potentiostat for clinical detection of SARS-CoV-2 Nucleocapsid proteins.

Authors:  Razieh Salahandish; Fatemeh Haghayegh; Giancarlo Ayala-Charca; Jae Eun Hyun; Mahmood Khalghollah; Azam Zare; Behrouz Far; Byron M Berenger; Yan Dong Niu; Ebrahim Ghafar-Zadeh; Amir Sanati-Nezhad
Journal:  Biosens Bioelectron       Date:  2022-01-25       Impact factor: 10.618

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.