Peri-implant bone microstructure determines dynamic implant cut-out.

Samuel E Basler1, John Traxler, Ralph Müller, G Harry van Lenthe.   

Abstract

Dynamic implant cut-out is a frequent complication associated with surgical fracture fixation. In this in vitro study, we investigated the influence of the local trabecular bone microstructure on the rate and path of implant migration. Dynamic hip screws were implanted into six human femoral head specimens with a wide range of bone volume fractions. The specimens were subjected to image-guided failure assessment using physiological dynamic hip loading. Mechanical testing was used intermittently with high-resolution computed tomography scanning. A high correlation was found between the bone volume fraction and implant migration (R(2)=0.95). Profiles of the bone-implant interface were computed based on the positions of the screw and the femoral head. With a larger interface, the implant migration rate was smaller. The bone-implant interface was significantly smaller on the approximated screw migration path than if it had been on a straight line in loading direction. We thus hypothesize that implants migrate on a path of least resistance. This would indicate a relevant mechanism for targeted surgical intervention.
Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone microstructure; Bone-implant interface; Dynamic hip screw (DHS); Dynamic implant cut-out; HR-pQCT; Image-guided failure assessment (IGFA); Time-lapsed imaging

Mesh:

Year:  2013        PMID: 23623173     DOI: 10.1016/j.medengphy.2013.03.016

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  Relationship between Ethane and Ethylene Diffusion inside ZIF-11 Crystals Confined in Polymers to Form Mixed-Matrix Membranes.

Authors:  Evan M Forman; Amineh Baniani; Lei Fan; Kirk J Ziegler; Erkang Zhou; Fengyi Zhang; Ryan P Lively; Sergey Vasenkov
Journal:  J Memb Sci       Date:  2019-09-03       Impact factor: 8.742

2.  Impaired bone formation in ovariectomized mice reduces implant integration as indicated by longitudinal in vivo micro-computed tomography.

Authors:  Zihui Li; Gisela Kuhn; Michael Schirmer; Ralph Müller; Davide Ruffoni
Journal:  PLoS One       Date:  2017-09-14       Impact factor: 3.240

3.  Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems.

Authors:  S Xie; K Manda; P Pankaj
Journal:  Bone Joint Res       Date:  2018-11-03       Impact factor: 5.853

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.