Dynamisation and early weight-bearing in tibial reamed intramedullary nailing: its safety and effect on fracture union.

Daniel Hernández-Vaquero1, Abelardo Suárez-Vázquez, Susana Iglesias-Fernández, Jesus García-García, Javier Cervero-Suárez.   

Abstract

AIM: To compare the safety and effect on tibial diaphyseal fracture bone union of two intramedullary nailing techniques: (1) dynamic locking with early, full weight bearing, and (2) static locking with delayed weight bearing until bone union. PATIENTS AND METHODS: This is a retrospective case-control study of closed or type I open tibial diaphyseal fractures (types A and B according to the AO classification) treated with dynamic nailing (32 cases) or static nailing (35 cases). The type of intramedullary nail, the surgical technique and the postoperative protocol were similar for both groups, with the exception of the locking mode and the time of weight bearing. Time to union, mechanical and biological complications, and the number and type of re-operations needed until union were recorded and analysed.
RESULTS: Mean union time was 21 weeks in the dynamic group and 26 in the static group (p = 0.051). In both groups 3 cases of nonunion were noted. In the dynamic group there was 1 case of delayed union and 1 case of malunion. In the static group, 5 cases of delayed union and 5 cases of malunion were found. Four reoperations were required in the dynamic group, whereas 10 were needed in the static group (p >0.05). Initial degree of interfragmentary gaps had an impact on the mean time to union and the appearance of biological complications in both groups.
CONCLUSION: Dynamic nailing assembly in intramedullary nailing in closed or type I open tibial diaphyseal fractures with limited comminution (types A and B according to the AO classification) is safe when used for these fracture types. A dynamic mode of nailing should be encouraged in these fracture patterns.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23622995     DOI: 10.1016/S0020-1383(13)70182-7

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  6 in total

1.  Comparison of dynamic versus static fixation of intramedullary nailing in tibial diaphyseal fractures: A systematic review and meta-analysis.

Authors:  Andre Jw Loh; James R Onggo; Jason Hockings; Iswadi Damasena
Journal:  J Clin Orthop Trauma       Date:  2022-07-19

2.  Preoperative determination of tibial nail length: An anthropometric study.

Authors:  Renjit-Thomas Issac; Hitesh Gopalan; Mathew Abraham; Cherian John; Sujith-Mathew Issac; Diju Jacob
Journal:  Chin J Traumatol       Date:  2016-06-01

3.  Correlation between tibial nail length and olecrenon to 5th metacarpal head measurement: An anthropometric study.

Authors:  Atmananda Hegde; Nabeel Mohammed; Naufal Rizwan Ahmed
Journal:  Chin J Traumatol       Date:  2019-08-09

4.  Aseptic femoral nonunion treated with exchange locked nailing with intramedullary augmentation cancellous bone graft.

Authors:  Chi-Chuan Wu
Journal:  J Orthop Surg Res       Date:  2022-07-06       Impact factor: 2.677

Review 5.  Outcomes of early versus delayed weight-bearing with intramedullary nailing of tibial shaft fractures: a systematic review and meta-analysis.

Authors:  Ameya Bhanushali; Joshua G Kovoor; Brandon Stretton; James T Kieu; Rebecca A Bright; Joseph N Hewitt; Christopher D Ovenden; Aashray K Gupta; Mohamed Z Afzal; Suzanne Edwards; Ruurd L Jaarsma; Christy Graff
Journal:  Eur J Trauma Emerg Surg       Date:  2022-03-03       Impact factor: 2.374

6.  The diaphyseal aseptic tibial nonunions after failed previous treatment options managed with the reamed intramedullary locking nail.

Authors:  Igor Kostic; Milan Mitkovic; Milorad Mitkovic
Journal:  J Clin Orthop Trauma       Date:  2017-08-24
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.