Literature DB >> 23622544

Application of dispersive liquid-liquid microextraction for the determination of phosphatidylethanol in blood by liquid chromatography tandem mass spectrometry.

Pamela Cabarcos1, José Ángel Cocho, Antonio Moreda, Martha Míguez, María Jesús Tabernero, Purificación Fernández, Ana María Bermejo.   

Abstract

Phosphatidylethanol (PEth) is a phospholipid which requires for its metabolic formation the presence of relatively high ethanol levels. PEth is thus a promising marker to quentify ethanol abuse. Dispersive liquid-liquid microextraction has become a popular technique because it is fast, inexpensive, easy to operate and consumes low volume of organic solvent. In this method, the appropriate mixture of extraction solvent (230 μL dichloromethane) and disperser solvent (630 μL acetone) are injected into the sample by syringe, rapidly. The liquid chromatography method using a reversed phase-C8 column and a negative ion mode electrospray ionization tandem mass spectrometry detection instrument was developed for the determination of small amounts of PEth that might be present in blood samples, using phosphatidylbutanol (PBut) as an internal standard. The sensitivity of detection obtained with tandem MS was better than that of previous methods. Good linearity was obtained for a range of LOQ-10 μg/mL for PEth, whereas all of the deviations in precision and accuracy were less than 15% except for the LLOQ, where it should not exceed 20%. A set of 50 blood samples were analyzed by such method and whole blood concentrations of PEth 16:0/18:1 ranged from LLOQ to 1.71 μg/mL.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23622544     DOI: 10.1016/j.talanta.2013.03.008

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Lung allograft donors with excessive alcohol use have increased levels of human antimicrobial peptide LL-37.

Authors:  M Camargo Moreno; J B Lewis; E J Kovacs; E M Lowery
Journal:  Alcohol       Date:  2018-11-09       Impact factor: 2.405

2.  Is it possible to detect PEth 16:0/18:1 and PEth 18:1/18:1 in red blood cells after 20 years of storage in liquid nitrogen?

Authors:  Robert Boll; Theron Johnson; Rudolf Kaaks; Tilman Kühn; Gisela Skopp
Journal:  Int J Legal Med       Date:  2017-06-24       Impact factor: 2.686

3.  Determination of Seven Antidepressants in Pericardial Fluid by Means of Dispersive Liquid-Liquid Microextraction (DLLME) and Gas Chromatography-Mass Spectrometry (GC/MS).

Authors:  P Cabarcos-Fernández; M J Tabernero-Duque; I Álvarez-Freire; A M Bermejo-Barrera
Journal:  J Anal Toxicol       Date:  2021-01-07       Impact factor: 3.367

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.