Literature DB >> 23621832

Laparoscopic left lateral sectionectomy with the use of Habib 4X: technical aspects.

Dimitris Zacharoulis1, Eleni Sioka, George Tzovaras, Long R Jiao, Nagy Habib.   

Abstract

INTRODUCTION: Various techniques and energy-based devices have been used to minimize the blood loss during transection of the liver parenchyma laparoscopically. The laparoscopic Habib™ 4X sealer (Rita Medical Systems, Inc., Fremont, CA) is a promising device using bipolar radiofrequency energy. The purpose of the study was to test the safety and the efficiency of the device in laparoscopic left lateral sectionectomy. PATIENTS AND METHODS: Five patients underwent laparoscopic left lateral sectionectomy using the laparoscopic Habib 4X in a period of 12 months. Indications for liver resection were hepatocellular carcinoma in 2 cirrhotic patients and colorectal cancer liver metastasis in 3 patients. Technical aspects were analyzed.
RESULTS: All the patients underwent formal laparoscopic left lateral sectionectomy. The Pringle maneuver was not applied in any of the patients. Mean operative time was 75 minutes (range, 60-90 minutes). Bleeding control along the transection line was satisfactory. No conversion to laparotomy was required. Operative blood loss was minimal. No blood transfusion was recorded. The postoperative period was uneventful. Median hospital stay was 3 days (range, 2-5 days). Histopathology revealed that the margins were disease free.
CONCLUSIONS: Laparoscopic left lateral segmentectomy with the use of Habib 4X proved safe and efficient. This technique may be an initial step for surgeons shifting to laparoscopic liver surgery provided they have previous experience in laparoscopic and liver surgery. Well-designed controlled randomized studies are needed in order to evaluate further the role of the device used in the present study in minimally invasive liver surgery.

Entities:  

Mesh:

Year:  2013        PMID: 23621832     DOI: 10.1089/lap.2012.0464

Source DB:  PubMed          Journal:  J Laparoendosc Adv Surg Tech A        ISSN: 1092-6429            Impact factor:   1.878


  3 in total

1.  915-MHz microwave-assisted laparoscopic hepatectomy: a new technique for liver resection.

Authors:  Xiaogang Dong; Zhongquan Sun; Tianchun Wu; Wenjia Guo; Sheng Yan; Shusen Zheng
Journal:  Surg Endosc       Date:  2018-10-29       Impact factor: 4.584

Review 2.  Laparoscopic liver resections for hepatocellular carcinoma: current role and limitations.

Authors:  Martin Gaillard; Hadrien Tranchart; Ibrahim Dagher
Journal:  World J Gastroenterol       Date:  2014-05-07       Impact factor: 5.742

3.  Modified laparoscopic hepatectomy for hepatic hemangioma.

Authors:  Dou-Sheng Bai; Ping Chen; Jian-Jun Qian; Jie Yao; Sheng-Jie Jin; Xiao-Dong Wang; Guo-Qing Jiang
Journal:  Surg Endosc       Date:  2015-01-01       Impact factor: 4.584

  3 in total