Literature DB >> 23619102

Spatial distribution of surface action potentials generated by individual motor units in the human biceps brachii muscle.

Javier Rodriguez-Falces1, Francesco Negro, Miriam Gonzalez-Izal, Dario Farina.   

Abstract

This study analyses the spatial distribution of individual motor unit potentials (MUPs) over the skin surface and the influence of motor unit depth and recording configuration on this distribution. Multichannel surface (13×5 electrode grid) and intramuscular (wire electrodes inserted with needles of lengths 15 and 25mm) electromyographic (EMG) signals were concurrently recorded with monopolar derivations from the biceps brachii muscle of 10 healthy subjects during 60-s isometric contractions at 20% of the maximum torque. Multichannel monopolar MUPs of the target motor unit were obtained by spike-triggered averaging of the surface EMG. Amplitude and frequency characteristics of monopolar and bipolar MUPs were calculated for locations along the fibers' direction (longitudinal), and along the direction perpendicular (transverse) to the fibers. In the longitudinal direction, monopolar and bipolar MUPs exhibited marked amplitude changes that extended for 16-32mm and 16-24mm over the innervation and tendon zones, respectively. The variation of monopolar and bipolar MUP characteristics was not symmetrical about the innervation zone. Motor unit depth had a considerable influence on the relative longitudinal variation of amplitude for monopolar MUPs, but not for bipolar MUPs. The transverse extension of bipolar MUPs ranged between 24 and 32mm, whereas that of monopolar MUPs ranged between 72 and 96mm. The mean power spectral frequency of surface MUPs was highly dependent on the transverse electrode location but not on depth. This study provides a basis for the interpretation of the contribution of individual motor units to the interference surface EMG signal.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23619102     DOI: 10.1016/j.jelekin.2013.03.011

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  7 in total

1.  Motor units in the human medial gastrocnemius muscle are not spatially localized or functionally grouped.

Authors:  Martin E Héroux; Harrison J Brown; J Timothy Inglis; Gunter P Siegmund; Jean-Sébastien Blouin
Journal:  J Physiol       Date:  2015-08-15       Impact factor: 5.182

2.  Correlation between discharge timings of pairs of motor units reveals the presence but not the proportion of common synaptic input to motor neurons.

Authors:  Javier Rodriguez-Falces; Francesco Negro; Dario Farina
Journal:  J Neurophysiol       Date:  2017-01-18       Impact factor: 2.714

3.  The formation of extracellular potentials over the innervation zone: Are these potentials affected by changes in fibre membrane properties?

Authors:  Javier Rodriguez-Falces
Journal:  Med Biol Eng Comput       Date:  2016-04-05       Impact factor: 2.602

4.  Regional activation within the vastus medialis in stimulated and voluntary contractions.

Authors:  Alessio Gallina; Tanya D Ivanova; S Jayne Garland
Journal:  J Appl Physiol (1985)       Date:  2016-06-30

5.  Differences in motor unit firing properties of the vastus lateralis muscle during postural and voluntary tasks.

Authors:  Toshiyuki Aoyama; Yutaka Kohno
Journal:  Front Physiol       Date:  2022-09-30       Impact factor: 4.755

6.  Performance Evaluation of a Wearable Tattoo Electrode Suitable for High-Resolution Surface Electromyogram Recording.

Authors:  Sourav Chandra; Jinghua Li; Babak Afsharipour; Andres F Cardona; Nina L Suresh; Limei Tian; Yujun Deng; Yishan Zhong; Zhaoqian Xie; Haixu Shen; Yonggang Huang; John A Rogers; William Z Rymer
Journal:  IEEE Trans Biomed Eng       Date:  2021-03-18       Impact factor: 4.538

7.  Spatial localization of electromyographic amplitude distributions associated to the activation of dorsal forearm muscles.

Authors:  Alessio Gallina; Alberto Botter
Journal:  Front Physiol       Date:  2013-12-13       Impact factor: 4.566

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.