Literature DB >> 23617091

Brand of dipotassium EDTA vacuum tube as a new source of pre-analytical variability in routine haematology testing.

G Lima-Oliveira1, G Lippi, G L Salvagno, M Montagnana, G Poli, G P Solero, G Picheth, G C Guidi.   

Abstract

This study assesses the use of different dry K2 (dipotassium) EDTA vacuum tubes and whether or not they might represent a bias in haematological testing. Blood was collected in three dipotassium EDTA vacuum tubes from different manufacturers: Venosafe, Vacuette and Vacutainer. Samples were analysed on an Advia 2120i analyser. Significant differences among results and biases were compared with current quality specifications. Significant differences were found for haematocrit (HCT), mean corpuscular volume (MCV), white blood cell count (WBC) and platelet distribution width (PDW) when comparing Venosafe vs. Vacuette; for MCV, WBC and PDW when comparing Venosafe vs. Vacutainer; and for HCT and MCV when comparing Vacuette vs. Vacutainer. Clinically significant variations were observed for HCT and PDW in Venosafe vs. Vacuette; PDW in Venosafe vs. Vacutainer; and HCT and MCV in Vacuette vs. Vacutainer. The use of dipotassium EDTA vacuum tubes from different manufacturers represent a clinically relevant source of variation for HCT, MCV and PDW.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23617091     DOI: 10.1080/09674845.2013.11669922

Source DB:  PubMed          Journal:  Br J Biomed Sci        ISSN: 0967-4845            Impact factor:   3.829


  5 in total

1.  A new device to relieve venipuncture pain can affect haematology test results.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Marise Danielle Raulino Campelo; Katharyne Soares Adala Tajra; Flavio dos Santos Gomes; Carlos David Valentim; Sylvio José Colonna Romano; Geraldo Picheth; Gian Cesare Guidi
Journal:  Blood Transfus       Date:  2013-07-18       Impact factor: 3.443

Review 2.  Design and Analysis for Studying microRNAs in Human Disease: A Primer on -Omic Technologies.

Authors:  Viswam S Nair; Colin C Pritchard; Muneesh Tewari; John P A Ioannidis
Journal:  Am J Epidemiol       Date:  2014-06-24       Impact factor: 4.897

3.  Contamination of lithium heparin blood by K2-ethylenediaminetetraacetic acid (EDTA): an experimental evaluation.

Authors:  Gabriel Lima-Oliveira; Gian Luca Salvagno; Elisa Danese; Giorgio Brocco; Gian Cesare Guidi; Giuseppe Lippi
Journal:  Biochem Med (Zagreb)       Date:  2014-10-15       Impact factor: 2.313

4.  Breakfast can Affect Routine Hematology and Coagulation Laboratory Testing: An Evaluation on Behalf of COLABIOCLI WG-PRE-LATAM.

Authors:  Maria Elena Arredondo; Eduardo Aranda; Rubén Astorga; Lorena Michele Brennan-Bourdon; Marise Danielle Campelo; Silvia Flores; Claudio Medel; Ignacio Manríquez; Patricia Ochoa; Beatriz Varela; Carlos Vega Salinas; Gabriel Lima-Oliveira
Journal:  TH Open       Date:  2019-12-17

5.  Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

  5 in total