Literature DB >> 23614708

Factors impacting echocardiographic imaging after the Fontan procedure: a report from the pediatric heart network fontan cross-sectional study.

Richard V Williams1, Renee Margossian, Minmin Lu, Andrew M Atz, Timothy J Bradley, Michael Jay Campbell, Steven D Colan, Dianne Gallagher, Wyman W Lai, Gail D Pearson, Ashwin Prakash, Girish Shirali, Meryl S Cohen.   

Abstract

Echocardiographic image quality in Fontan survivors may be limited by a variety of factors. We sought to describe echocardiographic quality and factors associated with study quality in subjects participating in the Pediatric Heart Network Fontan Cross-Sectional Study. Echocardiograms were obtained at 7 clinical sites using a standard protocol. Quality grading and analysis were performed by a core laboratory. Univariate and multivariable modeling were performed to assess factors associated with quality and ability to obtain images sufficient for prespecified quantitative analysis. A total of 543 echocardiograms were obtained. The quality of echocardiograms improved over the duration of the study. The great arteries, systemic veins, and pulmonary veins were less likely to be adequately imaged than other cardiac structures. Quantitative analysis of ventricular volume was possible in 76% overall, but only 41% of those with mixed ventricular morphology. Factors independently associated with better quality included younger age, levocardia, acquisition of the echocardiogram at a longer time since the beginning of enrollment, absence of a pulmonary artery stent, and clinical site. Patient and center-specific factors are associated with echocardiographic quality after the Fontan procedure. Increased familiarity and experience with a standard imaging protocol is likely to result in improved quality.
© 2013, Wiley Periodicals, Inc.

Entities:  

Keywords:  Fontan procedure; echocardiographic quality

Mesh:

Year:  2013        PMID: 23614708      PMCID: PMC3732542          DOI: 10.1111/echo.12219

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  16 in total

1.  Reliability of multicenter pediatric echocardiographic measurements of left ventricular structure and function: the prospective P(2)C(2) HIV study.

Authors:  S E Lipshultz; K A Easley; E J Orav; S Kaplan; T J Starc; J T Bricker; W W Lai; D S Moodie; G Sopko; M D Schluchter; S D Colan
Journal:  Circulation       Date:  2001-07-17       Impact factor: 29.690

2.  Improvement in the assessment of diastolic function in a clinical echocardiography laboratory following implementation of a quality improvement initiative.

Authors:  Thomas V Johnson; John D Symanski; Sanjay R Patel; Geoffrey A Rose
Journal:  J Am Soc Echocardiogr       Date:  2011-09-29       Impact factor: 5.251

3.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology.

Authors:  Roberto M Lang; Michelle Bierig; Richard B Devereux; Frank A Flachskampf; Elyse Foster; Patricia A Pellikka; Michael H Picard; Mary J Roman; James Seward; Jack S Shanewise; Scott D Solomon; Kirk T Spencer; Martin St John Sutton; William J Stewart
Journal:  J Am Soc Echocardiogr       Date:  2005-12       Impact factor: 5.251

4.  Design of a large cross-sectional study to facilitate future clinical trials in children with the Fontan palliation.

Authors:  Lynn A Sleeper; Page Anderson; Daphne T Hsu; Lynn Mahony; Brian W McCrindle; Stephen J Roth; J Phillip Saul; Richard V Williams; Tal Geva; Steven D Colan; Bernard J Clark
Journal:  Am Heart J       Date:  2006-09       Impact factor: 4.749

5.  Quality assessment and quality control of echocardiographic performance in a large multicenter international study: Valsartan in heart failure trial (Val-HeFT).

Authors:  Maylene Wong; Lidia Staszewsky; Alberto Volpi; Roberto Latini; Simona Barlera; Christer Höglund
Journal:  J Am Soc Echocardiogr       Date:  2002-04       Impact factor: 5.251

6.  Comparison of echocardiographic and cardiac magnetic resonance imaging measurements of functional single ventricular volumes, mass, and ejection fraction (from the Pediatric Heart Network Fontan Cross-Sectional Study).

Authors:  Renee Margossian; Marcy L Schwartz; Ashwin Prakash; Lisa Wruck; Steven D Colan; Andrew M Atz; Timothy J Bradley; Mark A Fogel; Lynne M Hurwitz; Edward Marcus; Andrew J Powell; Beth F Printz; Michael D Puchalski; Jack Rychik; Girish Shirali; Richard Williams; Shi-Joon Yoo; Tal Geva
Journal:  Am J Cardiol       Date:  2009-06-06       Impact factor: 2.778

7.  Magnetic resonance and echocardiographic imaging of pulmonary artery size throughout stages of Fontan reconstruction.

Authors:  M A Fogel; M T Donofrio; C Ramaciotti; A M Hubbard; P M Weinberg
Journal:  Circulation       Date:  1994-12       Impact factor: 29.690

8.  Contemporary outcomes after the Fontan procedure: a Pediatric Heart Network multicenter study.

Authors:  Page A W Anderson; Lynn A Sleeper; Lynn Mahony; Steven D Colan; Andrew M Atz; Roger E Breitbart; Welton M Gersony; Dianne Gallagher; Tal Geva; Renee Margossian; Brian W McCrindle; Stephen Paridon; Marcy Schwartz; Mario Stylianou; Richard V Williams; Bernard J Clark
Journal:  J Am Coll Cardiol       Date:  2008-07-08       Impact factor: 24.094

9.  Role of spin echo and cine magnetic resonance imaging in presurgical planning of heterotaxy syndrome. Comparison with echocardiography and catheterization.

Authors:  T Geva; G W Vick; R E Wendt; R Rokey
Journal:  Circulation       Date:  1994-07       Impact factor: 29.690

10.  Sex, age, and disease affect echocardiographic left ventricular mass and systolic function in the free-living elderly. The Cardiovascular Health Study.

Authors:  J M Gardin; D Siscovick; H Anton-Culver; J C Lynch; V E Smith; H S Klopfenstein; W J Bommer; L Fried; D O'Leary; T A Manolio
Journal:  Circulation       Date:  1995-03-15       Impact factor: 29.690

View more
  5 in total

1.  Impact of Variability in Echocardiographic Interpretation on Assessment of Adequacy of Repair Following Congenital Heart Surgery: A Pilot Study.

Authors:  Anitha Parthiban; Jami C Levine; Meena Nathan; Jennifer A Marshall; Girish S Shirali; Stephen D Simon; Steve D Colan; Jane W Newburger; Geetha Raghuveer
Journal:  Pediatr Cardiol       Date:  2015-09-10       Impact factor: 1.655

2.  Inefficient Ventriculoarterial Coupling in Fontan Patients: A Cardiac Magnetic Resonance Study.

Authors:  Max E Godfrey; Rahul H Rathod; Ellen Keenan; Kimberlee Gauvreau; Andrew J Powell; Tal Geva; Ashwin Prakash
Journal:  Pediatr Cardiol       Date:  2018-02-05       Impact factor: 1.655

3.  Sedated Echocardiograms Better Characterize Branch Pulmonary Arteries Following Bidirectional Glenn Palliation with Minimal Risk of Adverse Events.

Authors:  Jason L Williams; Muhammad Aanish Raees; Sudeep Sunthankar; Stacy A S Killen; David Bichell; David A Parra; Jonathan H Soslow
Journal:  Pediatr Cardiol       Date:  2020-04-04       Impact factor: 1.655

4.  Longitudinal Outcomes of Patients With Single Ventricle After the Fontan Procedure.

Authors:  Andrew M Atz; Victor Zak; Lynn Mahony; Karen Uzark; Nicholas D'agincourt; David J Goldberg; Richard V Williams; Roger E Breitbart; Steven D Colan; Kristin M Burns; Renee Margossian; Heather T Henderson; Rosalind Korsin; Bradley S Marino; Kaitlyn Daniels; Brian W McCrindle
Journal:  J Am Coll Cardiol       Date:  2017-06-06       Impact factor: 24.094

Review 5.  SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance.

Authors:  Tim Leiner; Jan Bogaert; Matthias G Friedrich; Raad Mohiaddin; Vivek Muthurangu; Saul Myerson; Andrew J Powell; Subha V Raman; Dudley J Pennell
Journal:  J Cardiovasc Magn Reson       Date:  2020-11-09       Impact factor: 5.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.