Literature DB >> 23612497

Evaluation of a Kalman-based block matching method to assess the bi-dimensional motion of the carotid artery wall in B-mode ultrasound sequences.

Guillaume Zahnd1, Maciej Orkisz, André Sérusclat, Philippe Moulin, Didier Vray.   

Abstract

We aim at investigating arterial diseases at early stage, by assessing the longitudinal (i.e. in the same direction as the blood flow) motion of the intima-media complex. This recently evidenced phenomenon has been shown to provide relevant and complementary information about vascular health. Our method assesses the longitudinal and radial motion from clinical in vivo B-mode ultrasound sequences. To estimate the trajectory of a selected point during the cardiac cycle, we introduce a block matching method that involves a temporal update of the reference block using a pixel-wise Kalman filter. The filter uses the initial gray-level of the pixel as control signal to avoid divergence due to cumulating errors. The block and search-window sizes are adapted to the tissue of interest. The method was evaluated on image sequences of the common carotid artery, acquired in 57 healthy volunteers and in 25 patients at high cardiovascular risk. Reference trajectories were generated for each sequence by averaging the tracings performed by three observers. Six different computerized techniques were also compared to our method. With a pixel size of 30 μm, the average absolute motion estimation errors were 84 ± 107 μm and 20 ± 19 μm for the longitudinal and radial directions, respectively. This accuracy was of the same order of magnitude as the inter- and intra-observers variability, and smaller than for the other methods. The estimated longitudinal motion amplitude was significantly reduced in at-risk patients compared with healthy volunteers (408 ± 281 μm vs. 643 ± 274 μm, p<0.0001). Our method can constitute a reliable and time-saving technique to investigate the arterial stiffness in clinical studies, in the objective to detect early-stage atherosclerosis.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23612497     DOI: 10.1016/j.media.2013.03.006

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  6 in total

1.  Role of ultrasonography in the evaluation of correlation between strain and elasticity of common carotid artery in patients with diabetic nephropathy.

Authors:  Chunpeng Zou; Yan Jiao; Xingwang Li; Chao Zheng; Maohua Chen; Chunhong Hu
Journal:  Int J Clin Exp Med       Date:  2015-10-15

2.  Tendon-motion tracking in an ultrasound image sequence using optical-flow-based block matching.

Authors:  Bo-I Chuang; Jian-Han Hsu; Li-Chieh Kuo; I-Ming Jou; Fong-Chin Su; Yung-Nien Sun
Journal:  Biomed Eng Online       Date:  2017-04-20       Impact factor: 2.819

3.  Post-exercise Endothelium-Dependent Vasodilation Is Dependent on Training Status.

Authors:  L V Kapilevich; V V Kologrivova; A N Zakharova; Laurent Mourot
Journal:  Front Physiol       Date:  2020-05-08       Impact factor: 4.566

4.  Arterial mechanical motion estimation based on a semi-rigid body deformation approach.

Authors:  Pablo Guzman; Ghassan Hamarneh; Rafael Ros; Eduardo Ros
Journal:  Sensors (Basel)       Date:  2014-05-27       Impact factor: 3.576

5.  A Preprocess Method of External Disturbance Suppression for Carotid Wall Motion Estimation Using Local Phase and Orientation of B-Mode Ultrasound Sequences.

Authors:  Qinghui Zhang; Junqiu Li; Zhenping Qiang; Libo He
Journal:  Biomed Res Int       Date:  2019-11-21       Impact factor: 3.411

6.  Regional thermal hyperemia in the human leg: Evidence of the importance of thermosensitive mechanisms in the control of the peripheral circulation.

Authors:  Nuno Koch Esteves; Oliver R Gibson; Ashraf W Khir; José González-Alonso
Journal:  Physiol Rep       Date:  2021-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.