Literature DB >> 23611993

Electrically elicited visual evoked potentials in Argus II retinal implant wearers.

H Christiaan Stronks1, Michael P Barry, Gislin Dagnelie.   

Abstract

PURPOSE: We characterized electrically elicited visual evoked potentials (eVEPs) in Argus II retinal implant wearers.
METHODS: eVEPs were recorded in four subjects, and analyzed by determining amplitude and latency of the first two positive peaks (P1 and P2). Subjects provided subjective feedback by rating the brightness and size of the phosphenes. We established eVEP input-output relationships, eVEP variability between and within subjects, the effect of stimulating different areas of the retina, and the maximal pulse rate to record eVEPs reliably.
RESULTS: eVEP waveforms had low signal-to-noise ratios, requiring long recording times and substantial signal processing. Waveforms varied between subjects, but showed good reproducibility and consistent parameter dependence within subjects. P2 amplitude overall was the most robust outcome measure and proved an accurate indicator of subjective threshold. Peak latencies showed small within-subject variability, yet their correlation with stimulus level and subjective rating were more variable than that of peak amplitudes. Pulse rates of up to (2)/3 Hz resulted in reliable eVEP recordings. Perceived phosphene brightness declined over time, as reflected in P1 amplitude, but not in P2 amplitude or peak latencies. Stimulating-electrode location significantly affected P1 and P2 amplitude and latency, but not subjective percepts.
CONCLUSIONS: While recording times and signal processing are more demanding than for standard visually evoked potential (VEP) recordings, the eVEP has proven to be a reliable tool to verify retinal implant functionality. eVEPs correlated with various stimulus parameters and with perceptual ratings. In view of these findings, eVEPs may become an important tool in functional investigations of retinal prostheses. (ClinicalTrials.gov number NCT00407602.) Dutch Abstract.

Entities:  

Keywords:  psychophysics; retinal implant; visual evoked potential; visual prosthesis

Mesh:

Year:  2013        PMID: 23611993      PMCID: PMC3676187          DOI: 10.1167/iovs.13-11594

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  38 in total

1.  Using independent component analysis to remove artifacts in visual cortex responses elicited by electrical stimulation of the optic nerve.

Authors:  Yiliang Lu; Pengjia Cao; Jingjing Sun; Jing Wang; Liming Li; Qiushi Ren; Yao Chen; Xinyu Chai
Journal:  J Neural Eng       Date:  2012-02-06       Impact factor: 5.379

2.  Interphase gap decreases electrical stimulation threshold of retinal ganglion cells.

Authors:  A C Weitz; M R Behrend; M S Humayun; R H Chow; J D Weiland
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

3.  Spatiotemporal properties of multipeaked electrically evoked potentials elicited by penetrative optic nerve stimulation in rabbits.

Authors:  Jingjing Sun; Yiliang Lu; Pengjia Cao; Xiaoliang Li; Changsi Cai; Xinyu Chai; Qiushi Ren; Liming Li
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-01-05       Impact factor: 4.799

4.  Measurement of evoked potentials after electrical stimulation of the human optic nerve.

Authors:  Marten E Brelén; Valerie Vince; Benoit Gérard; Claude Veraart; Jean Delbeke
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-05-12       Impact factor: 4.799

5.  Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis.

Authors:  Mohit N Shivdasani; Chi D Luu; Rosemary Cicione; James B Fallon; Penny J Allen; James Leuenberger; Gregg J Suaning; Nigel H Lovell; Robert K Shepherd; Chris E Williams
Journal:  J Neural Eng       Date:  2010-05-18       Impact factor: 5.379

6.  ISCEV standard for clinical visual evoked potentials (2009 update).

Authors:  J Vernon Odom; Michael Bach; Mitchell Brigell; Graham E Holder; Daphne L McCulloch; Alma Patrizia Tormene
Journal:  Doc Ophthalmol       Date:  2009-10-14       Impact factor: 2.379

7.  Interim results from the international trial of Second Sight's visual prosthesis.

Authors:  Mark S Humayun; Jessy D Dorn; Lyndon da Cruz; Gislin Dagnelie; José-Alain Sahel; Paulo E Stanga; Artur V Cideciyan; Jacque L Duncan; Dean Eliott; Eugene Filley; Allen C Ho; Arturo Santos; Avinoam B Safran; Aries Arditi; Lucian V Del Priore; Robert J Greenberg
Journal:  Ophthalmology       Date:  2012-01-11       Impact factor: 12.079

8.  Blind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task.

Authors:  A K Ahuja; J D Dorn; A Caspi; M J McMahon; G Dagnelie; L Dacruz; P Stanga; M S Humayun; R J Greenberg
Journal:  Br J Ophthalmol       Date:  2010-09-29       Impact factor: 4.638

9.  Inner and outer retinal mechanisms engaged by epiretinal stimulation in normal and rd mice.

Authors:  Eyal Margalit; Norbert Babai; Jianmin Luo; Wallace B Thoreson
Journal:  Vis Neurosci       Date:  2011-03       Impact factor: 3.241

10.  Response properties of electrically evoked potential elicited by multi-channel penetrative optic nerve stimulation in rabbits.

Authors:  Changsi Cai; Liming Li; Xiaoliang Li; Xinyu Chai; Jingjing Sun; Yiliang Lu; Xiaohong Sui; Panpan Chen; Qiushi Ren
Journal:  Doc Ophthalmol       Date:  2008-12-03       Impact factor: 2.379

View more
  7 in total

1.  Properties of electrically evoked potentials activated by optic nerve stimulation with penetrating electrodes of different modes in rabbits.

Authors:  Pengjia Cao; Jingjing Sun; Yan Yan; Yao Chen; Xinyu Chai; Xiaodong Sun; Qiushi Ren; Liming Li
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-07-31       Impact factor: 3.117

2.  Electrically evoked electroretinograms and pupil responses in Argus II retinal implant wearers.

Authors:  H Christiaan Stronks; Michael P Barry; Gislin Dagnelie
Journal:  Doc Ophthalmol       Date:  2016-01-07       Impact factor: 2.379

3.  Electrophysiological evaluation of a chronically implanted electrode for suprachoroidal transretinal stimulation in rabbit eyes.

Authors:  Kentaro Nishida; Hirokazu Sakaguchi; Motohiro Kamei; Toru Saito; Takashi Fujikado; Kohji Nishida
Journal:  J Artif Organs       Date:  2019-04-03       Impact factor: 1.731

4.  Spatial characteristics of evoked potentials elicited by a MEMS microelectrode array for suprachoroidal-transretinal stimulation in a rabbit.

Authors:  Yan Yan; Xiaohong Sui; Wenjia Liu; Yiliang Lu; Pengjia Cao; Zengguang Ma; Yao Chen; Xinyu Chai; Liming Li
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-05-16       Impact factor: 3.117

5.  Harmonization of Outcomes and Vision Endpoints in Vision Restoration Trials: Recommendations from the International HOVER Taskforce.

Authors:  Lauren N Ayton; Joseph F Rizzo; Ian L Bailey; August Colenbrander; Gislin Dagnelie; Duane R Geruschat; Philip C Hessburg; Chris D McCarthy; Matthew A Petoe; Gary S Rubin; Philip R Troyk
Journal:  Transl Vis Sci Technol       Date:  2020-07-16       Impact factor: 3.283

Review 6.  The functional performance of the Argus II retinal prosthesis.

Authors:  H Christiaan Stronks; Gislin Dagnelie
Journal:  Expert Rev Med Devices       Date:  2013-11-22       Impact factor: 3.166

7.  Retinal ganglion cell desensitization is mitigated by varying parameter constant excitation pulse trains.

Authors:  Wennan Li; Dorsa Haji Ghaffari; Rohit Misra; James D Weiland
Journal:  Front Cell Neurosci       Date:  2022-08-12       Impact factor: 6.147

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.