| Literature DB >> 23610855 |
M Bonnet1, X Wittebole, L M Jacquet, P Hantson.
Abstract
Refractory hypercapnia with severe acidosis appeared in a 67-year-old man who presented with lung fibrosis and a left pneumothorax as delayed complications of bleomycin chemotherapy for advanced grade lymphoma. Due to failure of noninvasive ventilation using a high-flow nasal cannula oxygen system, the patient was mechanically ventilated with two ventilators at different settings, after intubation with a double-lumen tube. As he had a poor haematological prognosis, extracorporeal membranous oxygenation was not considered. To remove some amount of carbon dioxide, we used a simplified method based on a veno-venous hemofiltration circuit coupled to a paediatric oxygenator and an air/oxygen blender. The efficacy on carbon dioxide removal was modest, with a percentage of CO2 total extraction ranging from 10.5 to 20.4%, but the system was immediately available, well tolerated and not very expensive.Entities:
Mesh:
Substances:
Year: 2012 PMID: 23610855
Source DB: PubMed Journal: Acta Anaesthesiol Belg ISSN: 0001-5164