Evaluation of X-Ray Beam Quality Based on Measurements and Estimations Using SpekCalc and Ipem78 Models.

Suk Chiang Chen1, Wei Loong Jong, Ahmad Zaky Harun.   

Abstract

BACKGROUND: Different computational methods have been used for the prediction of X-ray spectra and beam quality in diagnostic radiology. The purpose of this study was to compare X-ray beam qualities based on half-value layers (HVLs) determined through measurements and computational model estimations.
METHODS: The HVL estimations calculated by IPEM78 (Spectrum Processor of the Institute of Physics and Engineering in Medicine's Report 78) and SpekCalc software were compared with those determined through measurements. In this study, the HVLs of both Philips (Phil) (Philips Healthcare, Best, NL) and General Electric Company (GE) (GE Global Research, Niskayuna, US) diagnostic range X-ray machines (50 kVp to 125 kVp) were evaluated.
RESULTS: In the HVL estimations, SpekCalc and IPEM78 showed maximum differences of 10% and 9%, respectively, compared with direct measurements. Both models provided means and SDs of HVLs that were within 5% of the HVL measurements of GE and Phil machines.
CONCLUSION: Both computational models provide an alternative method for estimating the HVL of diagnostic range X-ray. These models are user-friendly in predicting HVLs, which are used to characterise the quality of the X-ray beam, and these models provide predictions almost instantly compared with experimental measurements.

Entities:  

Keywords:  HVL; IPEM78; SpekCalc; beam quality; effective energy

Year:  2012        PMID: 23610546      PMCID: PMC3629661     

Source DB:  PubMed          Journal:  Malays J Med Sci        ISSN: 1394-195X


  4 in total

1.  Evaluation of the use of six diagnostic X-ray spectra computer codes.

Authors:  P Meyer; E Buffard; L Mertz; C Kennel; A Constantinesco; P Siffert
Journal:  Br J Radiol       Date:  2004-03       Impact factor: 3.039

2.  Assessment of different computational models for generation of x-ray spectra in diagnostic radiology and mammography.

Authors:  M R Ay; S Sarkar; M Shahriari; D Sardari; H Zaidi
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

3.  SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes.

Authors:  G Poludniowski; G Landry; F DeBlois; P M Evans; F Verhaegen
Journal:  Phys Med Biol       Date:  2009-09-01       Impact factor: 3.609

4.  Equivalent half-value thicknesses and mean energies of filtered X-ray bremsstrahlung spectra.

Authors:  W W Seelentag; W Panzer
Journal:  Br J Radiol       Date:  1980-03       Impact factor: 3.039

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.