Literature DB >> 23608784

Angiographic findings of everolimus-eluting as compared to sirolimus-eluting stents: angiographic sub-study from the Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial (RESET).

Ken Kozuma1, Takeshi Kimura, Kazushige Kadota, Satoru Suwa, Kazuo Kimura, Masashi Iwabuchi, Kazuya Kawai, Akiyoshi Miyazawa, Masaki Kawamura, Koichi Nakao, Ryuta Asano, Takashi Yamamoto, Nobuaki Suzuki, Jiro Aoki, Hiroyuki Kyono, Gaku Nakazawa, Kengo Tanabe, Yoshihiro Morino, Keiichi Igarashi.   

Abstract

Several recent randomized trials comparing everolimus-eluting stent (EES) and sirolimus-eluting stent (SES) reported similar clinical outcomes. This study was aimed to clarify the differences in the angiographic findings of EES as compared to SES. Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial is a prospective multicenter randomized open-label trial comparing EES with SES in Japan. From February to July 2010, 3197 patients were randomly assigned to receive either EES or SES. Of these, angiographic sub-study enrolled 571 patients (EES 285 patients, SES 286 patients). Angiograms were assessed qualitatively and quantitatively at procedure and at 8-12 months in the independent core angiographic laboratory. Late loss of the proximal edges tended to be greater in the EES group than that in the SES group (0.12 ± 0.49 vs. 0.04 ± 0.43 mm, P = 0.05), although late loss in the other segments was similar between the 2 groups. Edge restenosis was mainly observed in EES group, whereas body restenosis was demonstrated in half of SES group. Stent fracture was observed only in the SES group (1.5 %), and peri-stent contrast staining (PSS) tended to be more frequently observed in the SES group than in the EES group (3.6 and 1.5 %, P = 0.18). Restenotic response in the proximal edge was more prominent in the EES group as compared to the SES group. Abnormal angiographic findings such as stent fracture and PSS tended to be more frequent in the SES group.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23608784     DOI: 10.1007/s12928-013-0179-7

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


  6 in total

1.  Side branch healing patterns of the Tryton dedicated bifurcation stent: a 1-year optical coherence tomography follow-up study.

Authors:  Maik J Grundeken; Hector M Garcia-Garcia; Robin P Kraak; P Woudstra; Daniel M de Bruin; Ton G van Leeuwen; Karel T Koch; Jan G Tijssen; Robbert J de Winter; Joanna J Wykrzykowska
Journal:  Int J Cardiovasc Imaging       Date:  2014-07-26       Impact factor: 2.357

Review 2.  Mechanisms of drug-eluting stent restenosis.

Authors:  Jiro Aoki; Kengo Tanabe
Journal:  Cardiovasc Interv Ther       Date:  2020-11-21

3.  Learning from the Cardiologists and Developing Eluting Stents Targeting the Mtor Pathway for Pulmonary Application; A Future Concept for Tracheal Stenosis.

Authors:  Paul Zarogoulidis; Kaid Darwiche; Kosmas Tsakiridis; Helmut Teschler; Lonny Yarmus; Konstantinos Zarogoulidis; Lutz Freitag
Journal:  J Mol Genet Med       Date:  2013-08-26

Review 4.  Drug Eluting Stents for Malignant Airway Obstruction: A Critical Review of the Literature.

Authors:  Wolfgang Hohenforst-Schmidt; Paul Zarogoulidis; Georgia Pitsiou; Bernd Linsmeier; Drosos Tsavlis; Ioannis Kioumis; Eleni Papadaki; Lutz Freitag; Theodora Tsiouda; J Francis Turner; Robert Browning; Michael Simoff; Nikolaos Sachpekidis; Kosmas Tsakiridis; Bojan Zaric; Lonny Yarmus; Sofia Baka; Grigoris Stratakos; Harald Rittger
Journal:  J Cancer       Date:  2016-01-13       Impact factor: 4.207

5.  Incidence of coronary drug-eluting stent fracture: A systematic review and meta-analysis.

Authors:  Yang Chen; Dandan Li; Yanhui Liao; Xiongda Yao; Yuehua Ruan; Kai Zou; Hanhui Liao; Jingwen Ding; Hao Qin; Zuozhong Yu; Yuanbin Zhao; Longlong Hu; Renqiang Yang
Journal:  Front Cardiovasc Med       Date:  2022-08-23

6.  Impact of Angiographic Residual Stenosis on Clinical Outcomes After New-Generation Drug-Eluting Stents Implantation: Insights From a Pooled Analysis of the RESET and NEXT Trials.

Authors:  Hiroki Watanabe; Takeshi Morimoto; Hiroki Shiomi; Masahiro Natsuaki; Kazuya Kawai; Ken Kozuma; Keiichi Igarashi; Kazushige Kadota; Kengo Tanabe; Yoshihiro Morino; Kiyoshi Hibi; Takashi Akasaka; Mitsuru Abe; Satoru Suwa; Toshiya Muramatsu; Masakazu Kobayashi; Kazuoki Dai; Koichi Nakao; Yasuhiro Tarutani; Kenshi Fujii; Takeshi Kimura
Journal:  J Am Heart Assoc       Date:  2018-06-30       Impact factor: 5.501

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.