Literature DB >> 2360298

Determination of tissue motion velocity by correlation interpolation of pulsed ultrasonic echo signals.

P G de Jong1, T Arts, A P Hoeks, R S Reneman.   

Abstract

Correlation interpolation is introduced as a method to determine the displacement of moving biological tissue on the basis of a sequence of ultrasonic echo signals. The echo signal is sampled along the echo depth with approximately 4 samples per average high frequency period. Sampling in time occurs with the pulse repetition frequency. The necessary information is extracted from a crosscorrelation function between successive signals, which is modelled using four parameters. The parameters are estimated from five calculated correlation sums and the shift with maximum correlation is determined. In contrast to existing techniques, the performance of this method is determined mainly by the number of samples used, while the ratio of the number of samples in depth and time is irrelevant. Using 64 samples at a signal-to-noise power ratio of 10, the standard deviation of the error in the determination of the shift in depth is 0.08 sampling intervals. As in many other methods, the width of the aliasing interval equals the mean frequency period.

Mesh:

Year:  1990        PMID: 2360298     DOI: 10.1177/016173469001200202

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  11 in total

1.  Maximum-likelihood approach to strain imaging using ultrasound

Authors: 
Journal:  J Acoust Soc Am       Date:  2000-03       Impact factor: 1.840

2.  Quantitative comparison of algorithms for tracking single fluorescent particles.

Authors:  M K Cheezum; W F Walker; W H Guilford
Journal:  Biophys J       Date:  2001-10       Impact factor: 4.033

3.  Non-bias-limited tracking of spherical particles, enabling nanometer resolution at low magnification.

Authors:  Marijn T J van Loenhout; Jacob W J Kerssemakers; Iwijn De Vlaminck; Cees Dekker
Journal:  Biophys J       Date:  2012-05-15       Impact factor: 4.033

Review 4.  Developments in cardiovascular ultrasound: Part 1: Signal processing and instrumentation.

Authors:  P J Fish; P R Hoskins; C Moran; W N McDicken
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

5.  Pulse wave imaging using coherent compounding in a phantom and in vivo.

Authors:  Iason Zacharias Apostolakis; Matthew D J McGarry; Ethan A Bunting; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2016-12-21       Impact factor: 3.609

6.  An approach to unbiased subsample interpolation for motion tracking.

Authors:  Matthew M McCormick; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

7.  Relation between regional electrical activation time and subepicardial fiber strain in the canine left ventricle.

Authors:  T Delhaas; T Arts; F W Prinzen; R S Reneman
Journal:  Pflugers Arch       Date:  1993-04       Impact factor: 3.657

8.  A new high-resolution spectral approach to noninvasively evaluate wall deformations in arteries.

Authors:  Ivonne Bazan; Carlos Negreira; Antonio Ramos; Javier Brum; Alfredo Ramirez
Journal:  Comput Math Methods Med       Date:  2014-02-13       Impact factor: 2.238

9.  3D functional ultrasound imaging of the cerebral visual system in rodents.

Authors:  Marc Gesnik; Kevin Blaize; Thomas Deffieux; Jean-Luc Gennisson; José-Alain Sahel; Mathias Fink; Serge Picaud; Mickaël Tanter
Journal:  Neuroimage       Date:  2017-02-03       Impact factor: 6.556

10.  Photoacoustic elastography imaging: a review.

Authors:  Mayanglambam Suheshkumar Singh; Anjali Thomas
Journal:  J Biomed Opt       Date:  2019-04       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.