Literature DB >> 23602723

Effect of B-value in revealing postinfarct myocardial microstructural remodeling using MR diffusion tensor imaging.

Yin Wu1, Chao Zou, Wei Liu, Weiqi Liao, Wei Yang, David A Porter, Xin Liu, Ed X Wu.   

Abstract

Nonmonoexponential diffusion behavior has been previously reported to exist in some biological tissues, making quantification of diffusion tensor imaging (DTI) indices dependent on diffusion sensitivity of b-value. This study aims to investigate the effect of b-value in revealing postinfarct myocardial microstructural remodeling in ex vivo hearts. DTI scans were performed on heart samples 1, 3, 5, and 7 days after infarction induction as well as intact controls with b-values of 500 to 2500s/mm(2). DTI indices, including fractional anisotropy (FA), and mean and directional diffusivities, were measured in infarct, adjacent and remote regions with zero and each non-zero b-values respectively using conventional DTI analysis. Experimental results showed that these DTI indices decreased gradually with b-values in all regions and groups. Optimal b-values were found to vary with targeted DTI indices, and could strengthen DTI ability in revealing myocardium degradation with using conventional DTI approach. Specifically, FA showed the most sensitive detection of fiber integrity degradation at moderate b-values (≈1500 to 2000s/mm(2)), and the greatest ability of mean and directional diffusivities in monitoring diffusivity alteration occurred at relatively small b-values (≤1500s/mm(2)) during the necrotic and fibrotic phases. These findings may provide useful information for DTI protocol parameter optimization in assessing heart microstructures at other pathological or in vivo states in the future.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23602723     DOI: 10.1016/j.mri.2013.02.010

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  7 in total

1.  Optimal preservation of porcine cardiac tissue prior to diffusion tensor magnetic resonance imaging.

Authors:  Peter Agger; Thomas Lass; Morten Smerup; Jesper Frandsen; Michael Pedersen
Journal:  J Anat       Date:  2015-09-22       Impact factor: 2.610

2.  Enhancement of the low resolution image quality using randomly sampled data for multi-slice MR imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-04

3.  Post-mortem cardiac diffusion tensor imaging: detection of myocardial infarction and remodeling of myofiber architecture.

Authors:  Sebastian Winklhofer; Christian T Stoeck; Nicole Berger; Michael Thali; Robert Manka; Sebastian Kozerke; Hatem Alkadhi; Paul Stolzmann
Journal:  Eur Radiol       Date:  2014-07-24       Impact factor: 5.315

4.  Adaptive anisotropic gaussian filtering to reduce acquisition time in cardiac diffusion tensor imaging.

Authors:  Ria Mazumder; Bradley D Clymer; Xiaokui Mo; Richard D White; Arunark Kolipaka
Journal:  Int J Cardiovasc Imaging       Date:  2016-02-02       Impact factor: 2.357

5.  Functional Assessment of Lumbar Nerve Roots Using Coronal-plane Single-shot Turbo Spin-echo Diffusion Tensor Imaging.

Authors:  Takayuki Sakai; Yasuchika Aoki; Atsuya Watanabe; Masami Yoneyama; Shigehiro Ochi; Tosiaki Miyati
Journal:  Magn Reson Med Sci       Date:  2019-06-13       Impact factor: 2.471

6.  Effect of b Value on Imaging Quality for Diffusion Tensor Imaging of the Spinal Cord at Ultrahigh Field Strength.

Authors:  Shu-Sheng Bao; Can Zhao; Xing-Xing Bao; Jia-Sheng Rao
Journal:  Biomed Res Int       Date:  2021-01-06       Impact factor: 3.411

7.  Evaluation of non-Gaussian diffusion in cardiac MRI.

Authors:  Darryl McClymont; Irvin Teh; Eric Carruth; Jeffrey Omens; Andrew McCulloch; Hannah J Whittington; Peter Kohl; Vicente Grau; Jürgen E Schneider
Journal:  Magn Reson Med       Date:  2016-09-26       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.