Consequence of use of lower dose flat plate fluoroscopy in pediatric patients undergoing ablation for supraventricular tachycardia.

David S Spar1, Jeffrey B Anderson, Lisa Lemen, Richard J Czosek, Timothy K Knilans.   

Abstract

Traditional imaging for ablation of supraventricular tachycardia has been fluoroscopy, although 3-dimensional electroanatomic mapping (3D) has been demonstrated to reduce radiation exposure. This study compares a technique for the reduction of radiation, low-dose fluoroscopy (LD), with standard-dose fluoroscopy (SD) and 3D with SD (3D-SD). This was a single institutional retrospective cohort study. All patients undergoing initial ablation for atrioventricular reentrant tachycardia (AVRT) or atrioventricular nodal reentrant tachycardia (AVNRT) from 2009 to 2012 were reviewed and divided into 3 groups: (1) SD, (2) 3D (CARTO or NavX) with SD, or (3) LD. LD uses the same equipment as SD but includes customized changes to the manufacturer's lowest settings by decreasing the requested dose to the detector. Primary outcomes were fluoroscopy time and dose area product exposure. One hundred eighty-one patients were included. The median age was 15.0 years (3.3-20.8); 59% had AVRT, 35% had AVNRT, and 6% had both AVRT and AVNRT. LD decreased the dose area product (DAP) compared with SD (637.0 vs 960.1 cGy*cm², p = 0.01) with no difference in fluoroscopy time. 3D-SD decreased fluoroscopy time compared with SD (9.9 vs 18.3 minutes, p <0.001) with DAP of 570.1.0 versus 960.1 cGy*cm² (p = 0.16). LD and 3D-SD had comparable DAP (637.0 vs 570.1 cGy*cm², p = 0.67), even though LD had significantly longer fluoroscopy time (19.9 vs 9.9 minutes, p <0.001). In conclusion, LD during catheter ablation of AVRT and AVNRT significantly reduced the DAP compared with SD and had similar radiation exposure compared with 3D with SD.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23601578     DOI: 10.1016/j.amjcard.2013.02.059

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  The Benefit of a General, Systematic Use of Mapping Systems During Electrophysiological Procedures in Children and Teenagers: The Experience of an Adult EP Laboratory.

Authors:  Massimiliano Marini; Maurizio Del Greco; Daniele Ravanelli; Anna Cima; Alessio Coser; Giulio Porcedda; Fabrizio Guarracini; Aldo Valentini; Roberto Bonmassari
Journal:  Pediatr Cardiol       Date:  2016-03-01       Impact factor: 1.655

2.  Getting to zero: impact of electroanatomical mapping on fluoroscopy use in pediatric catheter ablation.

Authors:  Bradley C Clark; Kohei Sumihara; Robert McCarter; Charles I Berul; Jeffrey P Moak
Journal:  J Interv Card Electrophysiol       Date:  2016-01-15       Impact factor: 1.900

3.  Safety and Efficacy of Radiofrequency Catheter Ablation for Tachyarrhythmia in Children Weighing Less Than 10 kg.

Authors:  Noriyasu Ozaki; Yoshihide Nakamura; Tsugutoshi Suzuki; Jun Yoshimoto; Keiko Toyohara; Hitoo Fukuhara; Hiroshi Katayama; Kanta Kishi; Yutaka Odanaka; Hiroshi Tamai
Journal:  Pediatr Cardiol       Date:  2017-11-08       Impact factor: 1.655

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.