The transverse relaxation signal from vegetal cells can be described by multi-exponential behaviour, reflecting different water compartments. This multi-exponential relaxation is rarely measured by conventional MRI imaging protocols; mono-exponential relaxation times are measured instead, thus limiting information about of the microstructure and water status in vegetal cells. In this study, an optimised multiple spin echo (MSE) MRI sequence was evaluated for assessment of multi-exponential transverse relaxation in fruit tissues. The sequence was designed for the acquisition of a maximum of 512 echoes. Non-selective refocusing RF pulses were used in combination with balanced crusher gradients for elimination of spurious echoes. The study was performed on a bi-compartmental phantom with known T2 values and on apple and tomato fruit. T2 decays measured in the phantom and fruit were analysed using bi- and tri-exponential fits, respectively. The MRI results were compared with low field non-spatially resolved NMR measurements performed on the same samples. The results demonstrated that the MSE-MRI sequence can be used for up to tri-exponential T2 quantification allowing for estimation of relaxation times from a few tens of milliseconds to over a second. The effects of the crusher moment and the TE value on T2 measurements were studied both on the bi-compartmental phantom and on the fruit tissues. It was demonstrated that the sequence should be optimised with regard to the characteristics of the tissue to be examined by considering the effects of water molecular diffusion in the presence of both imaging gradients and gradients produced by susceptibility inhomogeneities.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Fruit; Magnetic resonance imaging (MRI); Multi-exponential transverse (T(2)) relaxation; Plant; Relaxometry; Tissue characterisation

Mesh:

Year:  2013        PMID: 23601362     DOI: 10.1016/j.mri.2013.02.004

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Multicomponent T2 relaxation studies of the avian egg.

Authors:  Dimitris Mitsouras; Robert V Mulkern; Stephan E Maier
Journal:  Magn Reson Med       Date:  2015-06-02       Impact factor: 4.668

2.  A Weighted Stochastic Conjugate Direction Algorithm for Quantitative Magnetic Resonance Images-A Pattern in Ruptured Achilles Tendon T2-Mapping Assessment.

Authors:  Piotr A Regulski; Jakub Zielinski; Bartosz Borucki; Krzysztof Nowinski
Journal:  Healthcare (Basel)       Date:  2022-04-23

3.  Characterization of the Water Shortage Effects on Potato Tuber Tissues during Growth Using MRI Relaxometry and Biochemical Parameters.

Authors:  Ghina Hajjar; Stéphane Quellec; Sylvain Challois; Lydia Bousset-Vaslin; Gisèle Joly; Christophe Langrume; Carole Deleu; Laurent Leport; Maja Musse
Journal:  Plants (Basel)       Date:  2022-07-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.