W K Yoon1, R Choi, S G Lee, C Hyun. 1. Section of Small Animal Internal Medicine, College of Veterinary Medicine and Institute of Veterinary Science, Kangwon National University, Chuncheon 201-100, Korea.
Abstract
BACKGROUND: For treating dogs with heavy heartworm infection, mechanical removal using various retrieval devices is useful. However, the efficacy and safety of retrieval devices have rarely been studied. HYPOTHESIS: Catheter-based heartworm removal using 2 retrieval devices (basket and tripod grasping forceps) is efficient and safe for treating dogs with heavy worm burden. ANIMALS: Fifty-two client-owned dogs with heavy (Class III and IV) worm burden. METHODS: A retrospective study was performed on 52 dogs, using a catheter-based heartworm removal approach using 2 types of retrieval devices (ie, the basket and the tripod grasping forceps). The efficacy and complications associated with the 2 devices were assessed. RESULTS: The basket device was used on 22 of the study group dogs, and the tripod grasping forceps was used on 30 of the dogs. The postoperative survival rate was 95.5% for the basket device and 80% for the tripod grasping forceps, but the difference was not statistically significant. The worm number captured per attempt was 3.5 ± 1.7 using the basket device and 1.9 ± 0.85 for the tripod grasping forceps (P < .05). Various complications associated with heartworm removal were noticed with both retrieval devices. CONCLUSIONS AND CLINICAL IMPORTANCE: This study suggests that catheter-based heartworm removal is not only a relatively safe and efficient therapeutic method in dogs with heavy worm burden, but more efficient using the basket device. Our data do not indicate a clear safety advantage between the 2 devices evaluated, although the survival rate was numerically higher in dogs undergoing a basket intervention.
BACKGROUND: For treating dogs with heavy heartworm infection, mechanical removal using various retrieval devices is useful. However, the efficacy and safety of retrieval devices have rarely been studied. HYPOTHESIS: Catheter-based heartworm removal using 2 retrieval devices (basket and tripod grasping forceps) is efficient and safe for treating dogs with heavy worm burden. ANIMALS: Fifty-two client-owned dogs with heavy (Class III and IV) worm burden. METHODS: A retrospective study was performed on 52 dogs, using a catheter-based heartworm removal approach using 2 types of retrieval devices (ie, the basket and the tripod grasping forceps). The efficacy and complications associated with the 2 devices were assessed. RESULTS: The basket device was used on 22 of the study group dogs, and the tripod grasping forceps was used on 30 of the dogs. The postoperative survival rate was 95.5% for the basket device and 80% for the tripod grasping forceps, but the difference was not statistically significant. The worm number captured per attempt was 3.5 ± 1.7 using the basket device and 1.9 ± 0.85 for the tripod grasping forceps (P < .05). Various complications associated with heartworm removal were noticed with both retrieval devices. CONCLUSIONS AND CLINICAL IMPORTANCE: This study suggests that catheter-based heartworm removal is not only a relatively safe and efficient therapeutic method in dogs with heavy worm burden, but more efficient using the basket device. Our data do not indicate a clear safety advantage between the 2 devices evaluated, although the survival rate was numerically higher in dogs undergoing a basket intervention.
Authors: Ana Margarida Alho; António Fiarresga; Miguel Landum; Clara Lima; Óscar Gamboa; José Meireles; José Sales Luís; Luís Madeira de Carvalho Journal: Vet Med Int Date: 2016-02-11