Literature DB >> 23598954

Respiratory impedance in healthy subjects: baseline values and bronchodilator response.

Ellie Oostveen1, Krisztina Boda, Chris P M van der Grinten, Alan L James, Sally Young, Hans Nieland, Zoltán Hantos.   

Abstract

Because of the minimal demand for cooperation by the subject, the forced oscillation technique is increasingly employed in routine lung function testing. However, comprehensive and device-independent values of respiratory impedance at baseline and after bronchodilation have not been established for healthy adults. The aim of this multicentre study was to collect impedance data from 4 to 26 Hz in healthy Caucasian subjects between 18 and 80 years of age. Five different devices were employed to assess baseline values and the bronchodilator response. Altogether, 368 subjects were examined. Despite adjustment for anthropometry, the impedance spectra differed in frequency dependence between the centres, and hence could not be pooled. However, resistance at all frequencies except 20 and 25 Hz, and the low-frequency (≤14 Hz) values of reactance did not exhibit a centre dependence. The regression equations for resistance reflected a greater height dependence in males and a greater weight dependence in both males and females than those published previously. Bronchodilation resulted in a statistically significant decrease (11%) in resistance and a 95th percentile equal to a 32% decrease in resistance at low frequency. We conclude that rigorous calibration procedures should be developed to ensure data compatibility. Furthermore, new reference equations based on different setups are recommended to replace those established with a single device.

Mesh:

Substances:

Year:  2013        PMID: 23598954     DOI: 10.1183/09031936.00126212

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  48 in total

1.  Improvement in upright and supine lung mechanics with bariatric surgery affects bronchodilator responsiveness and sleep quality.

Authors:  Ubong Peters; Gail Dechman; Paul Hernandez; Swati Anil Bhatawadekar; James Ellsmere; Geoffrey Maksym
Journal:  J Appl Physiol (1985)       Date:  2018-07-26

2.  Discrepancy between in vivo and in vitro comparisons of forced oscillation devices.

Authors:  Sabine C Zimmermann; Joanna C Watts; Amy Bertolin; Kanika Jetmalani; Gregory G King; Cindy Thamrin
Journal:  J Clin Monit Comput       Date:  2017-07-31       Impact factor: 2.502

3.  Reactance and elastance as measures of small airways response to bronchodilator in asthma.

Authors:  S A Bhatawadekar; D Leary; V de Lange; U Peters; S Fulton; P Hernandez; C McParland; G N Maksym
Journal:  J Appl Physiol (1985)       Date:  2019-10-24

4.  Bronchodilator Response Assessed by the Forced Oscillation Technique Identifies Poor Asthma Control With Greater Sensitivity Than Spirometry.

Authors:  Alice M Cottee; Leigh M Seccombe; Cindy Thamrin; Gregory G King; Matthew J Peters; Claude S Farah
Journal:  Chest       Date:  2020-01-23       Impact factor: 9.410

5.  Lung Function in South African Adolescents Infected Perinatally with HIV and Treated Long-Term with Antiretroviral Therapy.

Authors:  Leah Nyawira Githinji; Diane M Gray; Sipho Hlengwa; Landon Myer; Heather J Zar
Journal:  Ann Am Thorac Soc       Date:  2017-05

Review 6.  The case for impulse oscillometry in the management of asthma in children and adults.

Authors:  Stanley P Galant; Hirsh D Komarow; Hye-Won Shin; Salman Siddiqui; Brian J Lipworth
Journal:  Ann Allergy Asthma Immunol       Date:  2017-06       Impact factor: 6.347

Review 7.  Lung Function Assessment by Impulse Oscillometry in Adults.

Authors:  Noemi Porojan-Suppini; Ovidiu Fira-Mladinescu; Monica Marc; Emanuela Tudorache; Cristian Oancea
Journal:  Ther Clin Risk Manag       Date:  2020-11-26       Impact factor: 2.423

8.  Lung disease burden assessment by oscillometry in a systematically disadvantaged urban population experiencing homelessness or at-risk for homelessness in Ottawa, Canada from a prospective observational study.

Authors:  Smita Pakhale; Carly Visentin; Saania Tariq; Tina Kaur; Kelly Florence; Ted Bignell; Sadia Jama; Nina Huynh; Robert Boyd; Joanne Haddad; Gonzalo G Alvarez
Journal:  BMC Pulm Med       Date:  2022-06-16       Impact factor: 3.320

Review 9.  Impedance Oscillometry: Emerging Role in the Management of Chronic Respiratory Disease.

Authors:  Mohammed F Zaidan; Ashwini P Reddy; Alexander Duarte
Journal:  Curr Allergy Asthma Rep       Date:  2018-01-29       Impact factor: 4.806

10.  Reference values of respiratory impedance with impulse oscillometry in healthy Chinese adults.

Authors:  Xiao-Lin Liang; Yi Gao; Wei-Jie Guan; Jing Du; Li Chen; Wen Han; Jin-Ming Liu; Yong Lu; Yi Peng; Bing-Rong Zhao; Tao Wang; Jin-Ping Zheng
Journal:  J Thorac Dis       Date:  2021-06       Impact factor: 2.895

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.