| Literature DB >> 23598824 |
Li-Mei Lin1, Shu-Fang Wang, Ru-Ping Lee, Bang-Gee Hsu, Nu-Man Tsai, Tai-Chu Peng.
Abstract
OBJECTIVE: This study evaluates the thermographic changes associated with moxa burner moxibustion at the SP6 acupuncture point to establish an appropriate, safe distance of efficacy for moxibustion.Entities:
Keywords: Acupuncture
Mesh:
Year: 2013 PMID: 23598824 PMCID: PMC3686262 DOI: 10.1136/acupmed-2012-010268
Source DB: PubMed Journal: Acupunct Med ISSN: 0964-5284 Impact factor: 2.267
Figure 1(A) A schematic diagram illustrating the experimental set up. (B) Moxibustion via moxa burner at SP6 acupuncture point as seen by infrared camera. SP01: Moxa cautery instrument rubber surface; AR02: moxa cautery instrument lignin surface.
Figure 2Changes in temperature on paper by moxibustion at different distances.
Figure 3Changes of temperature by moxibustion at different times (distance=3 cm). *p<0.01 indicates the moxibustion group's skin at SP6 at different time points compared with baseline by Wilcoxon signed rank test; #p<0.01 indicates the rest group's skin at different time points compared with baseline by Wilcoxon signed rank test.
Treatment effects at different time points (from baseline to 10th minute and p 10th minute)
| Measurement indices | From baseline to 10th minute | From baseline to p 10th minute | ||
|---|---|---|---|---|
| χ2 | p Value | χ2 | p Value | |
| Moxibustion (n=36) | ||||
| SP6T | 122.020 | <0.001*** | 139.943 | <0.001*** |
| Resting (n=36) | ||||
| SP6T | 14.596 | 0.012 | 14.347 | 0.014 |
Data show overall time point differences by Friedman test.
**p<0.01; ***p<0.001
10th minute, the 10th minute of moxibustion; p 10th minute, the 10th minute of rest after moxibustion; SP6T, SP6 acupuncture point temperature (°C).
Figure 4Changes of temperature by moxibustion at different times on moxa burner. #p<0.01 indicates SP6 at different time points compared with baseline by Wilcoxon signed rank test; +p<0.01 indicates SP01 (moxa cautery instrument rubber surface) at different time points compared with baseline by Wilcoxon signed rank test; *p<0.01 indicates AR02 (moxa cautery instrument wooden/plastic section) at different time points compared with baseline by Wilcoxon signed rank test. SP6T: SP6 acupuncture point temperature; SP01: moxa cautery instrument rubber surface; AR02: Moxa cautery instrument lignin surface.