Literature DB >> 23598774

The effect of PeakForce tapping mode AFM imaging on the apparent shape of surface nanobubbles.

Wiktoria Walczyk1, Peter M Schön, Holger Schönherr.   

Abstract

Until now, TM AFM (tapping mode or intermittent contact mode atomic force microscopy) has been the most often applied direct imaging technique to analyze surface nanobubbles at the solid-aqueous interface. While the presence and number density of nanobubbles can be unequivocally detected and estimated, it remains unclear how much the a priori invasive nature of AFM affects the apparent shapes and dimensions of the nanobubbles. To be able to successfully address the unsolved questions in this field, the accurate knowledge of the nanobubbles' dimensions, radii of curvature etc is necessary. In this contribution we present a comparative study of surface nanobubbles on HOPG (highly oriented pyrolytic graphite) in water acquired with (i) TM AFM and (ii) the recently introduced PFT (PeakForce tapping) mode, in which the force exerted on the nanobubbles rather than the amplitude of the resonating cantilever is used as the AFM feedback parameter during imaging. In particular, we analyzed how the apparent size and shape of nanobubbles depend on the maximum applied force in PFT AFM. Even for forces as small as 73 pN, the nanobubbles appeared smaller than their true size, which was estimated from an extrapolation of the bubble height to zero applied force. In addition, the size underestimation was found to be more pronounced for larger bubbles. The extrapolated true nanoscopic contact angles for nanobubbles on HOPG, measured in PFT AFM, ranged from 145° to 175° and were only slightly underestimated by scanning with non-zero forces. This result was comparable to the nanoscopic contact angles of 160°-175° measured using TM AFM in the same set of experiments. Both values disagree, in accordance with the literature, with the macroscopic contact angle of water on HOPG, measured here to be 63° ± 2°.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23598774     DOI: 10.1088/0953-8984/25/18/184005

Source DB:  PubMed          Journal:  J Phys Condens Matter        ISSN: 0953-8984            Impact factor:   2.333


  6 in total

1.  Perspectives on surface nanobubbles.

Authors:  Xuehua Zhang; Detlef Lohse
Journal:  Biomicrofluidics       Date:  2014-07-22       Impact factor: 2.800

2.  Pharmacokinetics of quercetin-loaded nanodroplets with ultrasound activation and their use for bioimaging.

Authors:  Li-Wen Chang; Mei-Ling Hou; Shuo-Hui Hung; Lie-Chwen Lin; Tung-Hu Tsai
Journal:  Int J Nanomedicine       Date:  2015-04-17

3.  Automatic morphological characterization of nanobubbles with a novel image segmentation method and its application in the study of nanobubble coalescence.

Authors:  Yuliang Wang; Huimin Wang; Shusheng Bi; Bin Guo
Journal:  Beilstein J Nanotechnol       Date:  2015-04-14       Impact factor: 3.649

4.  Air-water interface of submerged superhydrophobic surfaces imaged by atomic force microscopy.

Authors:  Markus Moosmann; Thomas Schimmel; Wilhelm Barthlott; Matthias Mail
Journal:  Beilstein J Nanotechnol       Date:  2017-08-11       Impact factor: 3.649

Review 5.  Imaging and Force Recognition of Single Molecular Behaviors Using Atomic Force Microscopy.

Authors:  Mi Li; Dan Dang; Lianqing Liu; Ning Xi; Yuechao Wang
Journal:  Sensors (Basel)       Date:  2017-01-22       Impact factor: 3.576

6.  Comparative study of plasmonic antennas fabricated by electron beam and focused ion beam lithography.

Authors:  Michal Horák; Kristýna Bukvišová; Vojtěch Švarc; Jiří Jaskowiec; Vlastimil Křápek; Tomáš Šikola
Journal:  Sci Rep       Date:  2018-06-25       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.