Literature DB >> 23598146

Trace lead analysis based on carbon-screen-printed-electrodes modified via 4-carboxy-phenyl diazonium salt electroreduction.

Sarra Bouden1, Annie Chaussé, Stephane Dorbes, Omar El Tall, Nizar Bellakhal, Mohamed Dachraoui, Christine Vautrin-Ul.   

Abstract

This paper describes the use of 4-carboxyphenyl-grafted screen-printed carbon electrodes (4-CP-SPEs) for trace lead analysis. These novel and simple use of electrodes were easily prepared by the electrochemical reduction of the corresponding diazonium salt. Pb detection was then performed by a three-steps method in order to avoid oxygen interference: (i) immersion of the grafted screen-printed electrode (SPE) in the sample and adsorption of Pb(II), (ii) reduction of adsorbed Pb(II) by chronoamperometry (CA), and (iii) oxidation of Pb by Anodic Square Wave Voltammetry (SWV). The reoxidation response was exploited for lead detection and quantification. In order to optimize the analytical responses, the influence of the adsorption medium pH and the adsorption time were investigated. Moreover, an interference study was carried out with Cu(II), Hg(II), Al(III), Mn(II), Zn(II), Cd(II) and no major interference can be expected to quantify Pb(II). The described method provided a limit of detection and a limit of quantification of 1.2 × 10(-9)M and 4.1 × 10(-9)M, respectively. These performances indicate that the 4-CP-SPE could be considered as an efficient tool for environmental analysis.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23598146     DOI: 10.1016/j.talanta.2013.01.021

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

Review 1.  Point-of-care biochemical assays using electrochemical technologies: approaches, applications, and opportunities.

Authors:  Qihong Ning; Shaoqing Feng; Yuemeng Cheng; Tangan Li; Daxiang Cui; Kan Wang
Journal:  Mikrochim Acta       Date:  2022-08-02       Impact factor: 6.408

Review 2.  Disposable screen printed electrochemical sensors: tools for environmental monitoring.

Authors:  Akhtar Hayat; Jean Louis Marty
Journal:  Sensors (Basel)       Date:  2014-06-13       Impact factor: 3.576

Review 3.  Electrochemical Biosensors: A Solution to Pollution Detection with Reference to Environmental Contaminants.

Authors:  Gustavo Hernandez-Vargas; Juan Eduardo Sosa-Hernández; Sara Saldarriaga-Hernandez; Angel M Villalba-Rodríguez; Roberto Parra-Saldivar; Hafiz M N Iqbal
Journal:  Biosensors (Basel)       Date:  2018-03-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.