Literature DB >> 23598040

Arsenic species determination in human scalp hair by pressurized hot water extraction and high performance liquid chromatography-inductively coupled plasma-mass spectrometry.

Andrés Morado Piñeiro1, Jorge Moreda-Piñeiro, Elia Alonso-Rodríguez, Purificación López-Mahía, Soledad Muniategui-Lorenzo, Darío Prada-Rodríguez.   

Abstract

Analytical methods for the determination of total arsenic and arsenic species (mainly As(III) and As(V)) in human scalp hair have been developed. Inductively coupled plasma-mass spectrometry (ICP-MS) and high performance liquid chromatography (HPLC) coupled to ICP-MS have been used for total arsenic and arsenic species determination, respectively. The proposed methods include a "green", fast, high efficient and automated species leaching procedure by pressurized hot water extraction (PHWE). The operating parameters for PHWE including modifier concentration, extraction temperature, static time, extraction steps, pressure, mean particle size, diatomaceous earth (DE) mass/sample mass ratio and flush volume were studied using design of experiments (Plackett-Burman design PBD). Optimum condition implies a modifier concentration (acetic acid) of 150 mM and powdered hair samples fully mixed with diatomaceous earth (DE) as a dispersing agent at a DE mass/sample mass ratio of 5. The extraction has been carried out at 100°C and at an extraction pressure of 1500 psi for 5 min in four extraction step. Under optimised conditions, limits of quantification of 7.0, 6.3 and 50.3 ng g(-1) for total As, As(III) and As(V), respectively were achieved. Repeatability of the overall procedure (4.4, 7.2 and 2.1% for total As, As(III) and As(V), respectively) was achieved. The analysis of GBW-07601 (human hair) certified reference material was used for validation. The optimised method has been finally applied to several human scalp hair samples.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23598040     DOI: 10.1016/j.talanta.2012.10.070

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Development of magnetic graphene oxide adsorbent for the removal and preconcentration of As(III) and As(V) species from environmental water samples.

Authors:  Hamid Rashidi Nodeh; Wan Aini Wan Ibrahim; Imran Ali; Mohd Marsin Sanagi
Journal:  Environ Sci Pollut Res Int       Date:  2016-02-06       Impact factor: 4.223

Review 2.  Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.

Authors:  Elizabeth S Hecht; Ann L Oberg; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-07       Impact factor: 3.109

Review 3.  On the Use of Hair Analysis for Assessing Arsenic Intoxication.

Authors:  Sidney A Katz
Journal:  Int J Environ Res Public Health       Date:  2019-03-18       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.