Literature DB >> 23598034

Non-enzymatic electrochemical glucose sensor based on platinum nanoflowers supported on graphene oxide.

Geng-huang Wu1, Xin-hong Song, Yan-fan Wu, Xiao-mei Chen, Feng Luo, Xi Chen.   

Abstract

A non-enzymatic electrochemical method was developed for glucose detection using a glassy carbon electrode modified with platinum nanoflowers supported on graphene oxide (PtNFs-GO). PtNFs-GO was synthesized using a nontoxic, rapid, one-pot and template-free method. Low-cost, green solvent ethanol acted as the reductant, and the advanced and effective 2D carbon material-GO nanosheet acted as the stabilizing material. Their morphologies were characterized using transmission electron microscopy. Cyclic voltammetry and amperometric methods were used to evaluate the electrocatalytic activity towards glucose in neutral media. The modified electrode exhibited strong and sensitive amperometric responses to glucose even in the presence of a high concentration of chloride ions. The response time was within 5s. The interference effects from ascorbic acid and uric acid were comparatively small when operated at suitable potential. Under optimal detection potential (0.47 V with a saturated calomel reference electrode) the PtNFs-GO modified electrode performed a current response towards glucose at a broad concentration range from 2 μM to 20.3mM. Two linear regions could be observed at 2 μM to 10.3mM with a sensitivity of 1.26 μA mM(-1)cm(-2) (correlation coefficient 0.9968), and at 10.3mM to 20.3mM with a sensitivity of 0.64 μA mM(-1)cm(-2)(correlation coefficient 0.9969). The LOD of 2 μM was lower than many non-enzymatic electrochemical glucose sensors. The modified electrode was also applied to the determination of glucose in glucose injection solutions, and the satisfactory results obtained indicated that it was promising for the development of a novel non-enzymatic electrochemical glucose sensor.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Year:  2012        PMID: 23598034     DOI: 10.1016/j.talanta.2012.10.066

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  10 in total

1.  A graphite pencil electrode with electrodeposited Pt-CuO for nonenzymatic amperometric sensing of glucose over a wide linear response range.

Authors:  Anjali Sreekumar; Punnakkal Navaneeth; Punathil Vasu Suneesh; Bipin G Nair; T G Satheesh Babu
Journal:  Mikrochim Acta       Date:  2020-01-09       Impact factor: 5.833

Review 2.  A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.

Authors:  Siva Kumar Krishnan; Eric Singh; Pragya Singh; Meyya Meyyappan; Hari Singh Nalwa
Journal:  RSC Adv       Date:  2019-03-18       Impact factor: 4.036

Review 3.  Graphene hybrids: synthesis strategies and applications in sensors and sensitized solar cells.

Authors:  Sushmee Badhulika; Trupti Terse-Thakoor; Claudia Villarreal; Ashok Mulchandani
Journal:  Front Chem       Date:  2015-06-30       Impact factor: 5.221

4.  Aminosilane-Assisted Electrodeposition of Gold Nanodendrites and Their Catalytic Properties.

Authors:  Nga Yu Hau; Peixian Yang; Chang Liu; Jian Wang; Po-Heng Lee; Shien-Ping Feng
Journal:  Sci Rep       Date:  2017-01-03       Impact factor: 4.379

5.  Small Naked Pt Nanoparticles Confined in Mesoporous Shell of Hollow Carbon Spheres for High-Performance Nonenzymatic Sensing of H2O2 and Glucose.

Authors:  Chunmei Zhang; Ruizhong Zhang; Xiaohui Gao; Chunfeng Cheng; Lin Hou; Xiaokun Li; Wei Chen
Journal:  ACS Omega       Date:  2018-01-05

6.  Performance-Enhanced Non-Enzymatic Glucose Sensor Based on Graphene-Heterostructure.

Authors:  Mahmoud A Sakr; Karim Elgammal; Anna Delin; Mohamed Serry
Journal:  Sensors (Basel)       Date:  2019-12-24       Impact factor: 3.576

7.  A comparative electrochemical study of non-enzymatic glucose, ascorbic acid, and albumin detection by using a ternary mesoporous metal oxide (ZrO2, SiO2 and In2O3) modified graphene composite based biosensor.

Authors:  Kamrun Nahar Fatema; Won-Chun Oh
Journal:  RSC Adv       Date:  2021-01-22       Impact factor: 3.361

8.  Self-template formation of porous Co3O4 hollow nanoprisms for non-enzymatic glucose sensing in human serum.

Authors:  Danhua Ge; Yunqi Yang; Xiao Ni; Jinnan Dong; Qianying Qiu; Xue-Qiang Chu; Xiaojun Chen
Journal:  RSC Adv       Date:  2020-10-19       Impact factor: 4.036

9.  Hybrid ZnO-graphene electrode with palladium nanoparticles on Ni foam and application to self-powered nonenzymatic glucose sensing.

Authors:  Wenyi Wu; Fengjuan Miao; Bairui Tao; Yu Zang; Lei Zhu; Cuiping Shi; Paul K Chu
Journal:  RSC Adv       Date:  2019-04-17       Impact factor: 3.361

10.  Development of micropillar array electrodes for highly sensitive detection of biomarkers.

Authors:  Chaozhan Chen; Bin Ran; Zhenxing Wang; Hongli Zhao; Minbo Lan; Huaying Chen; Yonggang Zhu
Journal:  RSC Adv       Date:  2020-11-10       Impact factor: 4.036

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.