Literature DB >> 23597903

Biodiesel content determination in diesel fuel blends using near infrared (NIR) spectroscopy and support vector machines (SVM).

Julio Cesar L Alves1, Ronei J Poppi.   

Abstract

This work verifies the potential of support vector machine (SVM) algorithm applied to near infrared (NIR) spectroscopy data to develop multivariate calibration models for determination of biodiesel content in diesel fuel blends that are more effective and appropriate for analytical determinations of this type of fuel nowadays, providing the usual extended analytical range with required accuracy. Considering the difficulty to develop suitable models for this type of determination in an extended analytical range and that, in practice, biodiesel/diesel fuel blends are nowadays most often used between 0 and 30% (v/v) of biodiesel content, a calibration model is suggested for the range 0-35% (v/v) of biodiesel in diesel blends. The possibility of using a calibration model for the range 0-100% (v/v) of biodiesel in diesel fuel blends was also investigated and the difficulty in obtaining adequate results for this full analytical range is discussed. The SVM models are compared with those obtained with PLS models. The best result was obtained by the SVM model using the spectral region 4400-4600 cm(-1) providing the RMSEP value of 0.11% in 0-35% biodiesel content calibration model. This model provides the determination of biodiesel content in agreement with the accuracy required by ABNT NBR and ASTM reference methods and without interference due to the presence of vegetable oil in the mixture. The best SVM model fit performance for the relationship studied is also verified by providing similar prediction results with the use of 4400-6200 cm(-1) spectral range while the PLS results are much worse over this spectral region.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23597903     DOI: 10.1016/j.talanta.2012.11.033

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Laser-Driven Calorimetry and Chemometric Quantification of Standard Reference Material Diesel/Biodiesel Fuel Blends.

Authors:  Werickson Fortunato de Carvalho Rocha; Cary Presser; Shannon Bernier; Ashot Nazarian; David A Sheen
Journal:  Fuel (Lond)       Date:  2020       Impact factor: 6.609

2.  Screening and validation for plasma biomarkers of nephrotoxicity based on metabolomics in male rats.

Authors:  Yubo Li; Haoyue Deng; Liang Ju; Xiuxiu Zhang; Zhenzhu Zhang; Zhen Yang; Lei Wang; Zhiguo Hou; Yanjun Zhang
Journal:  Toxicol Res (Camb)       Date:  2015-11-05       Impact factor: 3.524

3.  Multivariate Calibration for Carbon Nanotubes in the Environment Using the Microwave Induced Heating Method.

Authors:  Yang He; Souhail R Al-Abed; Dionysios D Dionysiou
Journal:  Environ Nanotechnol Monit Manag       Date:  2019

4.  Identification of Rice Varieties and Transgenic Characteristics Based on Near-Infrared Diffuse Reflectance Spectroscopy and Chemometrics.

Authors:  Yong Hao; Pei Geng; Wenhui Wu; Qinhua Wen; Min Rao
Journal:  Molecules       Date:  2019-12-13       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.