Literature DB >> 23597097

The Supralimus sirolimus-eluting stent.

Pedro A Lemos1, Igor Bienert.   

Abstract

The use of biodegradable polymeric coatings has emerged as a potential bioengineering target to improve the vascular compatibility of coronary drug-eluting stents (DESs). This review summarizes the main features and scientific facts about the Supralimus sirolimus-eluting stent (Sahajanand Medical Technologies Ltd, Surat, India), which is a biodegradable polymer-based, sirolimus-eluting metallic stent that was recently introduced for routine use in Europe. The novel stent is built on a stainless steel platform, coated with a blend of biodegradable polymers (poly-l-lactide, poly-dl-lactide-co-glycolide and polyvinyl pyrrolidone; coating thickness is 4-5 µm). The active agent is the antiproliferative sirolimus in a dose load of 1.4 µg/mm(2), which is released within 48 days. The Supralimus stent was initially evaluated in the single-arm SERIES-I study, which showed binary angiographic restenosis rates of 0% (in-stent) and 1.7% (in-segment) and an in-stent late lumen loss of 0.09 ± 0.28 mm. The multicenter randomized PAINT trial compared two DESs with identical metallic platforms and biodegradable polymer carriers, but different agents (Infinnium [Sahajanand Medical Technologies Pvt Ltd] paclitaxel-eluting stent or Supralimus sirolimus-eluting stent) against bare stents. After 3 years, the pooled DES population had similar rates of cardiac death or myocardial infarction (9 vs 7.1%; p = 0.6), but a lower risk of repeat interventions (10 vs 29.9%; p < 0.01) than controls with bare stents. The incidence of definite or probable stent thrombosis in the pooled DES group was 2.3% (1st year: 1.8%; 2nd year: 0.4% and 3rd year: 0%). These results demonstrate that the novel Supralimus stents are effective in reducing reintervention, while potentially improving the safety profile by decreasing the risk of late-term thrombosis, even though further studies would be necessary to confirm these findings.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23597097     DOI: 10.1586/erd.12.91

Source DB:  PubMed          Journal:  Expert Rev Med Devices        ISSN: 1743-4440            Impact factor:   3.166


  6 in total

1.  Learning from the Cardiologists and Developing Eluting Stents Targeting the Mtor Pathway for Pulmonary Application; A Future Concept for Tracheal Stenosis.

Authors:  Paul Zarogoulidis; Kaid Darwiche; Kosmas Tsakiridis; Helmut Teschler; Lonny Yarmus; Konstantinos Zarogoulidis; Lutz Freitag
Journal:  J Mol Genet Med       Date:  2013-08-26

Review 2.  Drug Eluting Stents for Malignant Airway Obstruction: A Critical Review of the Literature.

Authors:  Wolfgang Hohenforst-Schmidt; Paul Zarogoulidis; Georgia Pitsiou; Bernd Linsmeier; Drosos Tsavlis; Ioannis Kioumis; Eleni Papadaki; Lutz Freitag; Theodora Tsiouda; J Francis Turner; Robert Browning; Michael Simoff; Nikolaos Sachpekidis; Kosmas Tsakiridis; Bojan Zaric; Lonny Yarmus; Sofia Baka; Grigoris Stratakos; Harald Rittger
Journal:  J Cancer       Date:  2016-01-13       Impact factor: 4.207

Review 3.  Drug-Eluting Stents and Balloons-Materials, Structure Designs, and Coating Techniques: A Review.

Authors:  I Rykowska; I Nowak; R Nowak
Journal:  Molecules       Date:  2020-10-11       Impact factor: 4.411

Review 4.  A Toolbox of Potential Immune-Related Therapies for Inflammatory Cardiomyopathy.

Authors:  Ahmed Elsanhoury; Carsten Tschöpe; Sophie Van Linthout
Journal:  J Cardiovasc Transl Res       Date:  2020-05-21       Impact factor: 4.132

5.  Effectiveness of Direct Laser Interference Patterning and Peptide Immobilization on Endothelial Cell Migration for Cardio-Vascular Applications: An In Vitro Study.

Authors:  Romain Schieber; Carlos Mas-Moruno; Federico Lasserre; Joan Josep Roa; Maria-Pau Ginebra; Frank Mücklich; Marta Pegueroles
Journal:  Nanomaterials (Basel)       Date:  2022-04-05       Impact factor: 5.076

Review 6.  Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: a meta-analysis.

Authors:  Yanxiang Qiao; Yuan Bian; Xianliang Yan; Zhenfang Liu; Yuguo Chen
Journal:  Cardiovasc J Afr       Date:  2013-08       Impact factor: 1.167

  6 in total