Accuracy of a computer-aided implant surgical technique.

Michele Cassetta1, Luigi V Stefanelli, Matteo Giansanti, Alfonso Di Mambro, Sabrina Calasso.   

Abstract

The purpose of this in vivo retrospective study was to evaluate the accuracy of a computer-designed stereolithographic surgical guide. One hundred eleven implants were placed in 10 patients. Pre- and postoperative computed tomography images were compared using specific software. Global, angular, depth, and lateral deviations were calculated between planned and placed implants. Mean global deviations between planned and placed implants at the coronal and apical aspects were 1.52 mm (range, 0.13 to 3.00 mm) and 1.97 mm (range, 0.34 to 4.23 mm), respectively, while the mean angular deviation was 4.68 degrees (range, 0.10 to 15.25 degrees). This study highlighted a reasonable mean accuracy with relatively high maximum deviations between the postoperative position and the preoperative plan. These results should serve as a warning for the clinician if implants are placed near vital structures.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23593625     DOI: 10.11607/prd.1019

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  4 in total

1.  Comparison of Different Types of Static Computer-Guided Implant Surgery in Varying Bone Inclinations.

Authors:  Pisut Thangwarawut; Pokpong Amornvit; Dinesh Rokaya; Sirichai Kiattavorncharoen
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

2.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

3.  Assessment of the reproducibility and precision of milling and 3D printing surgical guides.

Authors:  Sueli Mukai; Eduardo Mukai; José Arnaldo Santos-Junior; Jamil Awad Shibli; Marcelo Faveri; Gabriela Giro
Journal:  BMC Oral Health       Date:  2021-01-02       Impact factor: 2.757

4.  Accuracy of computer-guided implantation in the placement of one-piece ceramic dental implants in the anterior region: A prospective clinical study.

Authors:  Nopparat Suksod; Chatchai Kunavisarut; Jira Kitisubkanchana
Journal:  PLoS One       Date:  2020-09-14       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.