Literature DB >> 23591186

Report on the Hemodialysis Reliable Outflow (HeRO) experience in dialysis patients with central venous occlusions.

Justin R Wallace1, Rabih A Chaer, Ellen D Dillavou.   

Abstract

OBJECTIVE: The Hemodialysis Reliable Outflow (HeRO) graft (Hemosphere/CryoLife Inc, Eden Prairie, Minn) has provided an innovative means to obtain hemodialysis access for patients with severe central venous occlusive disease. The outcomes of this novel treatment modality in a difficult population have yet to be clearly established.
METHODS: A retrospective review of HeRO graft placement from June 2010 to January 2012 was performed. Patient hemodialysis access history, clinical complexity, complications, and outcomes were analyzed. Categoric data were described with counts and proportions, and continuous data with means, ranges and, when appropriate, standard deviations. Patency rates were analyzed using life-table analysis, and patency rate comparisons were made with a two-group proportion comparison calculator.
RESULTS: HeRO graft placement was attempted 21 times in 19 patients (52% women), with 18 of 21 (86%) placed successfully. All but one was placed in the upper extremity. Mean follow-up after successful placement has been 7 months (range, 0-23 months). The primary indication for all HeRO graft placements except one was central vein occlusion(s) and need for arteriovenous access. Patients averaged 2.0 previous (failed) accesses and multiple catheters. Four HeRO grafts (24%), all in women, required ligation and removal for severe steal symptoms in the immediate postoperative period (P < .01 vs men). Three HeROs were placed above fistulas for rescue. All thrombosed <4 months, although the fistulas remained open. An infection rate of 0.5 bacteremic events per 1000 HeRO-days was observed. At a mean follow-up of 7 months, primary patency was 28% and secondary patency was 44%. The observed 12-month primary and secondary patency rates were 11% and 32%, respectively. Secondary patency was maintained in four patients for a mean duration of 10 months (range, 6-18 months), with an average of 4.0 ± 2.2 thrombectomies per catheter.
CONCLUSIONS: HeRO graft placement, when used as a last-resort measure, has been able to provide upper extremity access in patients who otherwise would not have this option. There is a high complication rate, however, including a very high incidence of steal in women. HeRO grafts should continue to be used as a last resort.
Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23591186      PMCID: PMC3976176          DOI: 10.1016/j.jvs.2013.02.018

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  9 in total

1.  Treatment strategies of arterial steal after arteriovenous access.

Authors:  Navyash Gupta; Theodore H Yuo; Gerhardt Konig; Ellen Dillavou; Steven A Leers; Rabih A Chaer; Jae S Cho; Michel S Makaroun
Journal:  J Vasc Surg       Date:  2011-01-26       Impact factor: 4.268

2.  Salvaging vascular access and treatment of severe limb edema: case reports on the novel use of the hemodialysis reliable outflow vascular access device.

Authors:  Shawn M Gage; Hardeep S Ahluwalia; Jeffrey H Lawson
Journal:  Ann Vasc Surg       Date:  2011-01-26       Impact factor: 1.466

3.  Modified use of the Hemodialysis Reliable Outflow (HeRO) graft for salvage of threatened dialysis access.

Authors:  Bassan J Allan; Angela T Prescott; Marwan Tabbara; Arash Bornak; Lee J Goldstein
Journal:  J Vasc Surg       Date:  2012-05-25       Impact factor: 4.268

Review 4.  Central venous disease in hemodialysis patients: prevalence, etiology and treatment.

Authors:  Sanjoy Kundu
Journal:  J Vasc Access       Date:  2010 Jan-Mar       Impact factor: 2.283

Review 5.  Dialysis fistula or graft: the role for randomized clinical trials.

Authors:  Michael Allon; Charmaine E Lok
Journal:  Clin J Am Soc Nephrol       Date:  2010-10-28       Impact factor: 8.237

6.  Long-term performance of the hemodialysis reliable outflow (HeRO) device: the 56-month follow-up of the first clinical trial patient.

Authors:  George M Nassar
Journal:  Semin Dial       Date:  2010 Mar-Apr       Impact factor: 3.455

7.  Results of a customer-based, post-market surveillance survey of the HeRO access device.

Authors:  Maureen Fusselman
Journal:  Nephrol News Issues       Date:  2010-08

8.  Initial experience and outcome of a new hemodialysis access device for catheter-dependent patients.

Authors:  Howard E Katzman; Robert B McLafferty; John R Ross; Marc H Glickman; Eric K Peden; Jeffery H Lawson
Journal:  J Vasc Surg       Date:  2009-07-22       Impact factor: 4.268

9.  Multi-center experience of 164 consecutive Hemodialysis Reliable Outflow [HeRO] graft implants for hemodialysis treatment.

Authors:  S M Gage; H E Katzman; J R Ross; S E Hohmann; C A Sharpe; D W Butterly; J H Lawson
Journal:  Eur J Vasc Endovasc Surg       Date:  2012-05-12       Impact factor: 7.069

  9 in total
  7 in total

Review 1.  Vascular access for hemodialysis: A perpetual challenge.

Authors:  Mariana Murea; Randolph L Geary; Ross P Davis; Shahriar Moossavi
Journal:  Semin Dial       Date:  2019-06-17       Impact factor: 3.455

Review 2.  Lower Extremity Permanent Dialysis Vascular Access.

Authors:  Vishal B Parekh; Vandana D Niyyar; Tushar J Vachharajani
Journal:  Clin J Am Soc Nephrol       Date:  2016-05-27       Impact factor: 8.237

3.  Multidisciplinary team approach to end-stage dialysis access patients.

Authors:  Clark Kensinger; Evan Brownie; Peter Bream; Derek Moore
Journal:  J Surg Res       Date:  2015-05-06       Impact factor: 2.192

Review 4.  Challenges and novel therapies for vascular access in haemodialysis.

Authors:  Jeffrey H Lawson; Laura E Niklason; Prabir Roy-Chaudhury
Journal:  Nat Rev Nephrol       Date:  2020-08-24       Impact factor: 28.314

Review 5.  Vascular Access for Placement of Tunneled Dialysis Catheters for Hemodialysis: A Systematic Approach and Clinical Practice Algorithm.

Authors:  Keith Pereira; Adam Osiason; Jason Salsamendi
Journal:  J Clin Imaging Sci       Date:  2015-05-29

6.  From ZeRO to HeRO: Saving lives one HeRO at a time.

Authors:  Dr Charlotte Ratcliff; Miss Monica Hansrani
Journal:  Int J Surg Case Rep       Date:  2016-08-04

7.  Safety and efficacy of a modified HeRO dialysis device in achieving early graft cannulation: A single-institution experience.

Authors:  John W Perry; David Hardy; Shvetank Agarwal; Gautam Agarwal
Journal:  J Vasc Surg Cases Innov Tech       Date:  2017-09-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.