Literature DB >> 23590392

Structure-function relationship among three types of spectral-domain optical coherent tomography instruments in measuring parapapillary retinal nerve fibre layer thickness.

Akiyasu Kanamori1, Makoto Nakamura, Mari Tomioka, Yuki Kawaka, Yuko Yamada, Akira Negi.   

Abstract

PURPOSE: To compare the relationships of parapapillary retinal nerve fibre layer (RNFL) thickness among three spectral-domain optical coherence tomography (SD-OCT) instruments with visual field sensitivity (VFS).
METHODS: One hundred and thirteen eyes of 113 Japanese subjects with glaucoma (mean deviation in standard automated perimetry = -8.9 ± 6.7 dB) were imaged by Cirrus, RTVue and 3D OCT. The average hemi-superior and hemi-inferior RNFL thicknesses were obtained. In addition, the structure-function relationship using two retinotopic maps that consisted of six or nine sectors was also evaluated. Decibel (dB) scale and 1/Lamert (1/L) were used to express VFS. RNFL thickness correlation with corresponding VFS in visual field sectors was compared among the three instruments. Background RNFL thickness (non-neuronal tissue) for each instrument was estimated using a linear regression model at 1/L = 0.
RESULTS: The correlation between the average hemi-superior and hemi-inferior RNFL thickness in the three SD-OCT instruments with corresponding VFS was similar. In the analysis of retinotopic maps, 3D OCT showed a higher correlation in superotemporal sectors than RTVue, whereas RTVue had a stronger relationship in the nasal sector than Cirrus. The background RNFL thickness extrapolated was approximately 60% that of normal eyes in all the instruments.
CONCLUSIONS: The three SD-OCT showed similar overall correspondence with VFS with a partially discordant retinotopic relationship. RNFL measured with any SD-OCT devices likely contains non-neuronal tissue, comprising 60% of its thickness.
© 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2013        PMID: 23590392     DOI: 10.1111/aos.12028

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  9 in total

1.  Difference in correspondence between visual field defect and inner macular layer thickness measured using three types of spectral-domain OCT instruments.

Authors:  Kaori Ueda; Akiyasu Kanamori; Azusa Akashi; Yuki Kawaka; Yuko Yamada; Makoto Nakamura
Journal:  Jpn J Ophthalmol       Date:  2014-11-07       Impact factor: 2.447

2.  Residual and Dynamic Range of Retinal Nerve Fiber Layer Thickness in Glaucoma: Comparison of Three OCT Platforms.

Authors:  Jean-Claude Mwanza; Hanna Y Kim; Donald L Budenz; Joshua L Warren; Michael Margolis; Scott D Lawrence; Pooja D Jani; Garrett S Thompson; Richard K Lee
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-10       Impact factor: 4.799

3.  Structure-Function Mapping Using a Three-Dimensional Neuroretinal Rim Parameter Derived From Spectral Domain Optical Coherence Tomography Volume Scans.

Authors:  Ali Riza Cenk Celebi; Elli A Park; Alice Chandra Verticchio Vercellin; Edem Tsikata; Ramon Lee; Eric Shieh; Hussein Antar; Madeline Freeman; Jing Zhang; Christian Que; Huseyin Simavli; Michael McClurkin; Rong Guo; Tobias Elze; Johannes F de Boer; Teresa C Chen
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

4.  Can Variability of Pattern ERG Signal Help to Detect Retinal Ganglion Cells Dysfunction in Glaucomatous Eyes?

Authors:  Alberto Mavilio; Francesca Scrimieri; Donato Errico
Journal:  Biomed Res Int       Date:  2015-06-08       Impact factor: 3.411

5.  Relationship between spectral-domain optical coherence tomography and standard automated perimetry in healthy and glaucoma patients.

Authors:  Beatriz Abadia; Antonio Ferreras; Pilar Calvo; Mirian Ara; Blanca Ferrandez; Sofia Otin; Paolo Frezzotti; Luis E Pablo; Michele Figus
Journal:  Biomed Res Int       Date:  2014-06-16       Impact factor: 3.411

6.  Multivariable logistic regression model: a novel mathematical model that predicts visual field sensitivity from macular ganglion cell complex thickness in glaucoma.

Authors:  Daisuke Shiba; Shin Hatou; Takeshi Ono; Shingo Hosoda; Sachiko Tanabe; Naoki Ozeki; Kenya Yuki; Masaru Shimoyama; Kazumi Fukagawa; Shigeto Shimmura; Kazuo Tsubota
Journal:  PLoS One       Date:  2014-08-18       Impact factor: 3.240

7.  OCTA Multilayer and Multisector Peripapillary Microvascular Modeling for Diagnosing and Staging of Glaucoma.

Authors:  Danilo Andrade De Jesus; Luisa Sánchez Brea; João Barbosa Breda; Ella Fokkinga; Vera Ederveen; Noor Borren; Amerens Bekkers; Michael Pircher; Ingeborg Stalmans; Stefan Klein; Theo van Walsum
Journal:  Transl Vis Sci Technol       Date:  2020-11-05       Impact factor: 3.283

8.  Angular Location of Retinal Nerve Fiber Layer Defect: Association With Myopia and Open-Angle Glaucoma.

Authors:  Eunoo Bak; Kyoung Min Lee; Martha Kim; Sohee Oh; Seok Hwan Kim
Journal:  Invest Ophthalmol Vis Sci       Date:  2020-09-01       Impact factor: 4.799

9.  Associations between structure and function are different in healthy and glaucomatous eyes.

Authors:  Fang-I Chu; Iván Marín-Franch; Koosha Ramezani; Lyne Racette
Journal:  PLoS One       Date:  2018-05-03       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.